Buildings, facilities and HVAC in FDA Form 483 observations

The plant itself: building design and repair, air handling, pressure differentials, temperature and humidity. FDAgent finds 160 such observations in 121 Form 483s issued to 117 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
160
Each quoted below
Form 483s
121
Posted by FDA
Facilities
117
Distinct FEIs
Most recent
Sep 10, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 49 in 2026

Facilities and HVAC observations in Form 483s by inspection year
YearObservations
20081
20091
20100
20110
20121
20131
20148
20157
20164
20176
20189
20199
20202
20218
202215
20238
202418
202513
202649

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.4221 CFR 211.4421 CFR 211.4621 CFR 211.4821 CFR 211.5021 CFR 211.5221 CFR 211.58

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“HVAC” · “air handl*” · “AHU*” · “pressure differential*” · “differential pressure*” · “temperature and humidity” · “humidity control*” · “humidity monitor*” · “air change*” · “air filtration” · “state of repair” · “ceiling tile*” · “peeling” · “flaking” · “water leak*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 160 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 2

    … Degraded caulking material is prone to cracking, flaking, and shedding, generating particles that can directly contaminate the critical production area and the sterile drug products prepared within it. Separation and cracking from the frame surface - The caulking appeared to be pulling away from and separating from the frame surface in areas, creating open crevices that cannot be cleaned or disinfected and that serve as harborage points for …

    Contains “flaking”Read the Form 483 →

  2. Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 5

    A pattern of frequent or acute pressure reversals was observed from areas of less clean air to areas of higher air cleanliness. Specifically, during a review of your firm's 2026 (b)(4) ISO Classified Cleanroom differential pressure monitoring logs approved by the firm's pharmacist for Cleanrooms Suites (b)(4), I found differential pressure reversals that occurred in the following months for Cleanroom a. February 2026 (18 out 22 Differential …

    Contains “differential pressure*”Read the Form 483 →

  3. Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 6

    … Manager reported that the contract cleanroom certifier had used the screwdriver to hold open the vent during an issue with balancing the ISO 8 Anteroom differential pressure. B. I found what appeared to be white foreign particulates on the floor within your firm's ISO 8 gowning room of Cleanroom Suite along with the vent remaining in the open position directly in front of the outside shoe storage rack.

    Contains “differential pressure*”Read the Form 483 →

  4. STAQ Pharma IncInspection ended Sep 8, 2026 · FEI 3015144909 · Observation 1

    Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair. Specifically, your firm does not maintain your facility adequately to prevent water intrusion into the mezzanine space directly above ISO-7 spaces utilized to produce injectable drug products purported to be sterile. On August 27, 2026, I observed standing water on top of non-impervious flooring within the mezzanine …

    Opens with FDA's citation wording for 21 CFR 211.58Read the Form 483 →

  5. RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 3

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Specifically, A. Personnel and material flow into and out of the ISO 7 and ISO 8 classified areas occurs through a single shared pathway that passes directly through the visual inspection and labeling room. Gowning, degowning, and material transfer — including finished product exiting the cleanroom and incoming …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(5)Read the Form 483 →

  6. OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 1

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, (A) The firm's environmental monitoring procedure does not require viable environmental monitoring during the initial aseptic setup of the (b)(4) filling line within the (b)(4) or during the initial aseptic setup of the (b)(4) automated filling machine positioned under [illegible] HEPA-filtered unidirectional airflow enclosure. Per …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  7. OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 6

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, (A) Your firm utilizes (b)(4) QA-access-controlled cabinets for the storage of sterilized machine (b)(4) parts and accessories. During inspection of these cabinets (b)(4) components, including a stopper bowl that directly contacts product stoppers, were observed without sterilization-status …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →

  8. Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 2

    A pattern of frequent or acute pressure reversals was observed from areas of less clean air to areas of higher air cleanliness. Specifically, from July 10, 2026 to August 21, 2026, your system for measuring pressure differential in the cleanrooms indicates negative pressure between the ISO 7 Buffer Room where the ISO 5 Laminar Flow Hoods are located and the ISO 8 Ante Room. The specification is (b)(4) w.c. and every data point documented in this …

    Contains “pressure differential*”Read the Form 483 →

  9. TAILSTORM HEALTH INCInspection ended Aug 28, 2026 · FEI 3015929581 · Observation 1

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, (b) (4) operational/dynamic certification of the (b) (4) Vial Filling, Stoppering and Sealing Machine, ISO 5 (b) (4) Filling Line cleanroom suite does not represent routine production operations. For example, ISO 5 Filling Line was not fully assembled or in-operation, and there was one …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →

  10. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 1

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, A. Your cleanroom certification conducted on June 29, 2026, and June 30, 2026, shows that HEPA Filter [illegible] in Production Room [illegible] (ISO 7) did not pass airflow and (b)(4) as the report states the result as N/A and notes "HEPA Filter 8 in need of motor replacement." Your firm …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →

  11. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 4

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed (b)(4), were reviewed. During this video review the following was observed: 1. Your production operators were observed placing the settle plates in the corners of the LAFHs before the start …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  12. OurPharma LLCInspection ended Aug 12, 2026 · FEI 3014064135 · Observation 1

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, • (b)(4) Sterilization Performed in an ISO 8 Classified Room Batch records collected during the inspection confirm that (b)(4) sterilization was performed in Compounding Room (b)(4) which is classified as ISO 8. Specifically: Batch production records for two lots of Fentanyl …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →

  13. Glenmark Pharmaceuticals LimitedInspection ended Jun 30, 2026 · FEI 3004672766 · Observation 4

    Control systems for the firm's operations are not adequate to prevent contamination or mix-ups. Specifically, A. Differential pressure in the manufacturing areas of the (b)(4) facility (Unit (b)(4)) is not adequately monitored and recorded, and no alarm system is in place to detect differential pressure excursions. A review of the Batch Production Record (BPR) for Batch (b)(4) ((b)(4) USP (b)(4) mcg), confirmed that the differential pressure is …

    Contains “differential pressure*”Read the Form 483 →

  14. Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 1

    … Peeling tape and proliferated surfaces covering the (b)(4) (b)(4) media plate stands stationed throughout the Grade A environment. 5. Unsmooth and rusted (b)(4) surfaces on the (b)(4). 6. Multiple visible (b)(4) scratches on the (b)(4) of the vial filling line. 7. Multiple visible black and (b)(4) marks/scratches on the (b)(4) empty vial machine. 8. Indented hole and extraneous black material observed on the camera mount surface stationed within …

    Contains “peeling”Read the Form 483 →

  15. XeCare LLCInspection ended Jun 17, 2026 · FEI 3017865039 · Observation 1

    … Review of the Building Management System (BMS) data for Room 104 from 5/13/2026 through 6/10/2026 revealed approximately 56 pressure differential alarm events, with excursion durations ranging from 5 minutes to a continuous all-day alarm on 6/9/2026. During this period, your firm actively weighed, sifted, or mixed, approximately [illegible] batches while alarm limits were exceeded. Batches weighed and sifted during this period include but are not …

    Contains “pressure differential*”Read the Form 483 →

  16. Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 6

    Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, on 6/1/2026, a divot approximately two to four inches long was observed approximately one foot off the ground on the corner of a wall pillar in ISO-5 Room 149A Sterile Staging, Building 25 Commerce, immediately next to the exit door of the (b)(4) oven. Similarly, on 6/2/2026, a floor divot approximately one inch in …

    Opens with FDA's citation wording for 21 CFR 211.58Read the Form 483 →

  17. Eisai Company Ltd.Inspection ended Jun 5, 2026 · FEI 3004967045 · Observation 1

    … The air handling units supplying the manufacturing space were also located in this area. Your firm stated (b) (4) falls out of the (b) (4) when they are emptied. Your firm's SOP (number MJ302-01-EG0001) for cleaning the machine room instructs employees to promptly clean up after working with the (b) (4) This SOP also instructs the person in charge to conduct (b) (4) patrols of the machine room and look for dust. Pharmaceutical Manufacturing …

    Contains “air handl*”Read the Form 483 →

  18. Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 7

    Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, observations include, but are not limited to, the following: • Peeling and Chipped Paint - Non-Hazardous Oncology Pharmacy SCA - Peeling and chipped paint was observed on both sides of the door frame and surrounding walls of the non-hazardous Oncology Pharmacy Segregated Compounding Area (SCA). This room contains …

    Contains “peeling”Read the Form 483 →

  19. Annovex Pharma IncInspection ended Jun 3, 2026 · FEI 3020928491 · Observation 1

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, your firm failed to ensure that the laminar airflow hoods used for the production of sterile and non-sterile drug products were maintained in a state of adequate control. In a cleanroom certification conducted on January 28, 2026, all (b)(4) laminar airflow hoods at your facility were found to be operating …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  20. PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 2

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm has not established adequate procedures and controls for the maintenance, certification, and qualification of HEPA filters, laminar air flow hoods (LAFH), biological safety cabinets (BSC), and cleanroom HVAC systems used for sterile drug production. HVAC failures …

    Contains “HVAC”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about facilities and HVAC in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.