IntegraDose Compounding Services LLC
Minnesota
FEI 3014483112
FDA has 5 inspections on file for IntegraDose Compounding Services LLC in Minnesota (FEI 3014483112), from 2018 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Mar 1, 2024. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 5, 2018–2026
- 3 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 5
- Requested under FOIA
- 2 requests, latest Jun 24, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Aseptic areas deficient for contamination prevention
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, A. Your cleanroom certification conducted on June 29, 2026, and June 30, 2026, shows that HEPA Filter [illegible] in Production Room [illegible] (ISO 7) did not pass airflow and (b)(4) as the report states the result as N/A and notes "HEPA Filter 8 in need of motor replacement." Your firm produced (b)(4) batches of drug products in Production Room [illegible] between June 30, 2026, and August 4, 2026, (b)(4) of which have been distributed. No investigation or CAPA has been opened to assess the impact of this specific HEPA Filter on your operations. B. During the inspection walk through of your classified spaces on August 7, 2026, it was observed that HEPA filters in your ISO 7 production areas are equipped with indicator lights. Of the ten (10) HEPA filters observed, nine (9) displayed red indicator lights and one (1) displayed a green indicator light across the following areas: Production Room [illegible] two (2) red indicator lights, Production Room [illegible] three (3) red indicator lights and one (1) green indicator light, Production Room [illegible] four (4) red indicator lights. Your firm explained that a green light indicates the HEPA filter is functioning and a red light indicates an issue with the filter. However, your firm was unable to identify the specific issue or issues indicated by the red-light status, had no documented procedure specifying the required response when a red light is displayed, and had no knowledge of when each affected HEPA filter began displaying the red light. Your firm did not restrict production activities in the affected areas or conduct an impact assessment on compounded drug products produced while these HEPA filters were displaying a red indicator light. C. On August 5, 2026, while reviewing video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed on (b)(4), it was observed there were up to [illegible] personnel present in Production Room [illegible] and (b)(4) operators in (b)(4) ISO 5 LAFH ((b)(4)) during production operations. Your cleanroom certification report for June 29, 2026, and June 30, 2026, states that all (b)(4) of your classified spaces were certified under dynamic conditions with five personnel present. However, on August 10, 2026, a video of the firm's certification activities was reviewed. During this review, it was observed that only the certifier was present in each production room when (b)(4) certified. Additionally, your ISO 5 LAFHs (Production Room [illegible] (b)(4), Production Room [illegible] Production Room [illegible] (b)(4)) were all certified under dynamic conditions with one operator per the certification report. D. On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed (b)(4), were reviewed. During this video review several instances of poor aseptic practice were observed: 1. Operators were not consistently wiping components before introduction into the ISO 5 LAFH space from the ISO 7 Production Room space. 2. Operators were moving quickly throughout the cleanroom space and within the ISO 5 LAFH. The tossing of components into the ISO 5 LAFH space was also observed. This batch of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, completed on (b)(4), was released and distributed. E. Continuing assessment for operator gowning qualification uses postproduction batch EM for assessment. Personnel sampling for gowning qualification should occur immediately after gowning and gloving. Using postproduction [illegible] sampling does not show the operator's ability to gown properly. Additionally, twelve (12) of your (b)(4) operators did not perform initial hand hygiene and gowning qualifications at this location, they were carried over from IntegraDo
Shortened here; the PDF has the full text.
- Observation 2
Quality control unit procedures not followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. Your firm qualifies visual inspectors and AQL inspectors on (b)(4) basis. The following deficiencies in inspector qualification were identified during the inspection: 1. Following the start of operations at your new facility on February 2, 2026, your firm did not perform requalification of visual inspectors or AQL inspectors for the new facility. Instead, your firm continued to use qualifications performed at your previous facility. No assessment or justification for carrying over previous facility qualifications to the new facility was identified during the inspection. Visual inspection qualification is specific to the environment and equipment under which it is performed and qualifications conducted at a previous facility cannot be assumed to remain valid under the different conditions of a new facility. 2. In May 2026, your firm introduced (b)(4) new visual inspection booths in a new visual inspection room at your current facility. Your firm did not perform requalification of visual inspectors for these new booths prior to their use. As of the date of this inspection, inspectors have been performing visual inspection using these booths for approximately three months without qualification. 3. (b)(4) AQL inspectors have not performed any visual inspection or AQL inspection requalification since your firm began operations at the new facility in February 2026. These inspectors have performed AQL inspection on over (b)(4) batches between February 2026 and the date of this inspection, all of which have been distributed. Additionally, your AQL inspections are conducted by Production staff, your Quality Unit does not participate in AQL inspections. B. Your firm's process media fill (MFP), qualifying your operators to perform aseptic operations, were not signed by your Quality Unit before your operators participated in production batches: Process Media Fill Elapsed Event Date Completed Date Signed by Quality Unit Associated Time [illegible] January 19, 2026 April 8, 2026 No Events 79 days [illegible] January 26, 2026 April 22, 2026 No Events 86 days [illegible] January 7, 2026 March 11, 2026 No Events 63 days [illegible] January 5, 2026 March 4, 2026 58 days [illegible] January 13, 2026 [illegible] April 8, 2026 EV2319, EV2318 85 days. C. Your batch records do not document critical pieces of information related to the production and release of your drug products. Examples include but are not limited to the following: 1. Your firm uses a (b)(4) (Model (b)(4)) to (b)(4) incoming materials with a (b)(4) prior to introduction into the ISO 7 classified space. Per your firm, materials are (b)(4) and brought into the ISO 7 space. This (b)(4) process occurs in either the "Wipe" or "Wipe" room and is governed by Work Instruction WI-0040 for (b)(4). However, the time at which (b)(4) begins, the (b)(4) step, and the room in which (b)(4) occurs are not, dwell time for (b)(4) documented in the batch record. 2. Specific times and locations (Visual Inspection Room (b)(4)) that visual inspection took place, number of units visually inspected by each visual inspector, or when required breaks were taken by visual inspectors are not documented. 3. LUX lighting level of visual inspection areas is not documented prior to conducting visual inspection. D. Your Quality Unit is not fulfilling its responsibility to ensure that your operations and processes are accurately described in current Standard Operating Procedures: 1. Your CADD (b)(4) process is governed by SOP-0055 for (b)(4) maintenance, Effective date March 1, 2017. This SOP states "This machine is currently only approved for applying a tamper-evident (b)(4) on PCA vial products." According to your firm you have not used PCA vial products in approximately 7 years. Your firm is currently using the (b)(4) to create tamper evident (b)(4) on CADD products. No SOP governing
Shortened here; the PDF has the full text.
Show observations 3 to 4
- Observation 3
Inadequate aseptic process validation smoke studies
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, Smoke studies conducted on December 31, 2025, did not adequately reflect observed production operations. On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed on (b)(4), were reviewed. The following discrepancies were observed in the smoke study videos: 1. The batch video, during production, showed (b)(4) operators performing individual tasks in each ISO 5 Laminar Airflow Hood (LAFH). The smoke studies only demonstrated one operator individually performing one task in each video. 2. The smoke study for the CADDs products shows the CADDs lined up with about 2-3 inches of space between the CADD and the back wall of the (b)(4) airflow LAFH. During the batch video the CADDs were observed to be placed directly in front of the back wall with no gap. The smoke study did not evaluate this product placement configuration and therefore does not demonstrate that unidirectional airflow adequately protects the critical compounding area under actual production conditions. Additionally, during production, CADDs were observed blocking first air for components placed behind the CADDs and the connectors of the CADDs were observed resting on the back wall of the LAFH where the HEPA filter is located. This batch of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, completed on (b)(4), was released and distributed.
- Observation 4
Environmental monitoring system deficient
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed (b)(4), were reviewed. During this video review the following was observed: 1. Your production operators were observed placing the settle plates in the corners of the LAFHs before the start of the batch. Your SOP-0015 Environmental Monitoring (EM) Program: 503B Cleanroom, states placement should be "(b)(4) from the back/HEPA filter." 2. Your firm does not document the time post production EM samples are taken.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.
Show 1 more citation
Acceptance/Rejection Levels
The statistical quality control criteria fail to include appropriate rejection levels.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
- FDCA 503B(b)(2)(A)
Outsourcing facility, compounded drug report follow up
Your outsourcing facility did not submit a report to FDA identifying the drugs compounded during the previous six month period.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
Show 3 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Defined areas of adequate size for operations
The control systems necessary to prevent contamination or mix-ups are deficient.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Written sanitation procedures lacking
There is a lack of written procedures describing in sufficient detail the methods, equipment and materials to be used for sanitation.
Test devices not meeting specifications
Test devices are deficient in that instruments not meeting established specifications are used.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 1 more citation
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jun 24, 2026. Each one asked for a Form 483.
Inspection ending Mar 1, 2024OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jun 24, 2026FDA-FOIA-2026-6067Form 483Referred to Alternative Access Process
- Aug 8, 2024FDA-FOIA-2024-7109Form 483· 1 of 5 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit4 of 4
- 21 CFR 211.42Design and construction features4 of 4
- 21 CFR 211.113Control of microbiological contamination4 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.56Sanitation1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.160General requirements1 of 4
Show all 10
- 21 CFR 211.165Testing and release for distribution1 of 4
- 21 CFR 211.194Laboratory records1 of 4
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014483112 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014483112. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.