IntegraDose Compounding Services LLC Form 483, August 2026

FDA issued this Form 483 to IntegraDose Compounding Services LLC in Minnesota (FEI 3014483112) at the end of an inspection that ended August 12, 2026. It lists 4 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Sep 22, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 12, 2026
—
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Sep 22, 2026
41 days after the inspection
Facility
FEI 3014483112
Minnesota

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Aseptic areas deficient for contamination prevention

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, A. Your cleanroom certification conducted on June 29, 2026, and June 30, 2026, shows that HEPA Filter [illegible] in Production Room [illegible] (ISO 7) did not pass airflow and (b)(4) as the report states the result as N/A and notes "HEPA Filter 8 in need of motor replacement." Your firm produced (b)(4) batches of drug products in Production Room [illegible] between June 30, 2026, and August 4, 2026, (b)(4) of which have been distributed. No investigation or CAPA has been opened to assess the impact of this specific HEPA Filter on your operations. B. During the inspection walk through of your classified spaces on August 7, 2026, it was observed that HEPA filters in your ISO 7 production areas are equipped with indicator lights. Of the ten (10) HEPA filters observed, nine (9) displayed red indicator lights and one (1) displayed a green indicator light across the following areas: Production Room [illegible] two (2) red indicator lights, Production Room [illegible] three (3) red indicator lights and one (1) green indicator light, Production Room [illegible] four (4) red indicator lights. Your firm explained that a green light indicates the HEPA filter is functioning and a red light indicates an issue with the filter. However, your firm was unable to identify the specific issue or issues indicated by the red-light status, had no documented procedure specifying the required response when a red light is displayed, and had no knowledge of when each affected HEPA filter began displaying the red light. Your firm did not restrict production activities in the affected areas or conduct an impact assessment on compounded drug products produced while these HEPA filters were displaying a red indicator light. C. On August 5, 2026, while reviewing video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed on (b)(4), it was observed there were up to [illegible] personnel present in Production Room [illegible] and (b)(4) operators in (b)(4) ISO 5 LAFH ((b)(4)) during production operations. Your cleanroom certification report for June 29, 2026, and June 30, 2026, states that all (b)(4) of your classified spaces were certified under dynamic conditions with five personnel present. However, on August 10, 2026, a video of the firm's certification activities was reviewed. During this review, it was observed that only the certifier was present in each production room when (b)(4) certified. Additionally, your ISO 5 LAFHs (Production Room [illegible] (b)(4), Production Room [illegible] Production Room [illegible] (b)(4)) were all certified under dynamic conditions with one operator per the certification report. D. On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed (b)(4), were reviewed. During this video review several instances of poor aseptic practice were observed: 1. Operators were not consistently wiping components before introduction into the ISO 5 LAFH space from the ISO 7 Production Room space. 2. Operators were moving quickly throughout the cleanroom space and within the ISO 5 LAFH. The tossing of components into the ISO 5 LAFH space was also observed. This batch of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, completed on (b)(4), was released and distributed. E. Continuing assessment for operator gowning qualification uses postproduction batch EM for assessment. Personnel sampling for gowning qualification should occur immediately after gowning and gloving. Using postproduction [illegible] sampling does not show the operator's ability to gown properly. Additionally, twelve (12) of your (b)(4) operators did not perform initial hand hygiene and gowning qualifications at this location, they were carried over from IntegraDo

    Shortened here; the PDF has the full text.

  2. 2

    Quality control unit procedures not followed

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. Your firm qualifies visual inspectors and AQL inspectors on (b)(4) basis. The following deficiencies in inspector qualification were identified during the inspection: 1. Following the start of operations at your new facility on February 2, 2026, your firm did not perform requalification of visual inspectors or AQL inspectors for the new facility. Instead, your firm continued to use qualifications performed at your previous facility. No assessment or justification for carrying over previous facility qualifications to the new facility was identified during the inspection. Visual inspection qualification is specific to the environment and equipment under which it is performed and qualifications conducted at a previous facility cannot be assumed to remain valid under the different conditions of a new facility. 2. In May 2026, your firm introduced (b)(4) new visual inspection booths in a new visual inspection room at your current facility. Your firm did not perform requalification of visual inspectors for these new booths prior to their use. As of the date of this inspection, inspectors have been performing visual inspection using these booths for approximately three months without qualification. 3. (b)(4) AQL inspectors have not performed any visual inspection or AQL inspection requalification since your firm began operations at the new facility in February 2026. These inspectors have performed AQL inspection on over (b)(4) batches between February 2026 and the date of this inspection, all of which have been distributed. Additionally, your AQL inspections are conducted by Production staff, your Quality Unit does not participate in AQL inspections. B. Your firm's process media fill (MFP), qualifying your operators to perform aseptic operations, were not signed by your Quality Unit before your operators participated in production batches: Process Media Fill Elapsed Event Date Completed Date Signed by Quality Unit Associated Time [illegible] January 19, 2026 April 8, 2026 No Events 79 days [illegible] January 26, 2026 April 22, 2026 No Events 86 days [illegible] January 7, 2026 March 11, 2026 No Events 63 days [illegible] January 5, 2026 March 4, 2026 58 days [illegible] January 13, 2026 [illegible] April 8, 2026 EV2319, EV2318 85 days. C. Your batch records do not document critical pieces of information related to the production and release of your drug products. Examples include but are not limited to the following: 1. Your firm uses a (b)(4) (Model (b)(4)) to (b)(4) incoming materials with a (b)(4) prior to introduction into the ISO 7 classified space. Per your firm, materials are (b)(4) and brought into the ISO 7 space. This (b)(4) process occurs in either the "Wipe" or "Wipe" room and is governed by Work Instruction WI-0040 for (b)(4). However, the time at which (b)(4) begins, the (b)(4) step, and the room in which (b)(4) occurs are not, dwell time for (b)(4) documented in the batch record. 2. Specific times and locations (Visual Inspection Room (b)(4)) that visual inspection took place, number of units visually inspected by each visual inspector, or when required breaks were taken by visual inspectors are not documented. 3. LUX lighting level of visual inspection areas is not documented prior to conducting visual inspection. D. Your Quality Unit is not fulfilling its responsibility to ensure that your operations and processes are accurately described in current Standard Operating Procedures: 1. Your CADD (b)(4) process is governed by SOP-0055 for (b)(4) maintenance, Effective date March 1, 2017. This SOP states "This machine is currently only approved for applying a tamper-evident (b)(4) on PCA vial products." According to your firm you have not used PCA vial products in approximately 7 years. Your firm is currently using the (b)(4) to create tamper evident (b)(4) on CADD products. No SOP governing

    Shortened here; the PDF has the full text.

  3. 3

    Inadequate aseptic process validation smoke studies

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, Smoke studies conducted on December 31, 2025, did not adequately reflect observed production operations. On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed on (b)(4), were reviewed. The following discrepancies were observed in the smoke study videos: 1. The batch video, during production, showed (b)(4) operators performing individual tasks in each ISO 5 Laminar Airflow Hood (LAFH). The smoke studies only demonstrated one operator individually performing one task in each video. 2. The smoke study for the CADDs products shows the CADDs lined up with about 2-3 inches of space between the CADD and the back wall of the (b)(4) airflow LAFH. During the batch video the CADDs were observed to be placed directly in front of the back wall with no gap. The smoke study did not evaluate this product placement configuration and therefore does not demonstrate that unidirectional airflow adequately protects the critical compounding area under actual production conditions. Additionally, during production, CADDs were observed blocking first air for components placed behind the CADDs and the connectors of the CADDs were observed resting on the back wall of the LAFH where the HEPA filter is located. This batch of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, completed on (b)(4), was released and distributed.

  4. 4

    Environmental monitoring system deficient

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed (b)(4), were reviewed. During this video review the following was observed: 1. Your production operators were observed placing the settle plates in the corners of the LAFHs before the start of the batch. Your SOP-0015 Environmental Monitoring (EM) Program: 503B Cleanroom, states placement should be "(b)(4) from the back/HEPA filter." 2. Your firm does not document the time post production EM samples are taken.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3014483112, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.