Greenwich Rx Form 483, September 2026
FDA issued this Form 483 to Greenwich Rx in Texas (FEI 3043120213) at the end of an inspection that ended September 9, 2026. It lists 14 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 21, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 9, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Oct 21, 2026
- 42 days after the inspection
The 14 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Dietary supplement grade API in sterile injectable
Use of ingredients not intended for pharmaceutical use in sterile drug production. Specifically, your firm was found to use a reduced dietary supplement grade APIs in the compounding of finished sterile drug product, Glutathione Injection 200mg/mL. For example, the API, Glutathione (L) USP (Reduced) (Dietary Supplement Grade), Lot (b)(4), Expiry (b)(4) was used in the compounding of the finished sterile drug, Glutathione Injection 200mg/mL Lot 0060061826-1, BUD 09-26-2026. This lot was dispensed to fill patient-specific prescriptions. The firm continues to receive this grade of API based on a review of supplier provided COAs for Glutathione (L) USP.
- 2
Sterile production during adjacent uncontrolled construction
Your firm produced drugs while construction was underway in an adjacent area without adequate controls to prevent contamination of the production environment and product. Specifically, A. On 8/17/2026, during a site walk-through, I found construction with sheet rock in areas surrounding a newly constructed ISO Classified modular Cleanroom Suite occurring at the same time as compounding activities within ISO (b)(4) modular cleanrooms (Suites (b)(4)) located in the same general area separated by a wall not extended to the facility ceiling. Your firm's management reported construction activities had been occurring approximately three (3) weeks prior to the start of this FDA inspection. Your firm was compounding the sterile drugs, Tirzepatide 30mg/B12 0.5mg/mL (2.4mL) 30mg/0.5mg mg/mL, Lot number 0011081726-1 (b)(4) BUD 2026-11-25, Batch size vials and Semaglutide 10mg/B12 0.5mg/mL (1.3mL) 10mg/0.5mg, Lot number 0005081726-1, BUD 2026-11-25, Batch size (b)(4) vials. B. During my walk-through of your site, white foreign particulate matter and debris was observed within the vents of the ISO 8 Anteroom open to the non-controlled/unclassified area and through-out the construction area where the new ISO Classified Cleanroom Suite was under construction as a result of your firm's active construction and equipment installation.
- 3
ISO 5 microbial contamination without investigation
Microbial contamination was present in the ISO 5 area and areas adjacent to production areas. Specifically, during my review of your firm's environmental monitoring (EM) records, I found the following deficiencies: A. During a review of your firm's 2025 (b)(4) EM monitor sampling of the ISO Classified Cleanroom Suite I found two (2) different occurrences where 1 CFU was found during ISO 5 LAFC surface sampling (Acceptance Limits ISO Class 5: (b)(4)). These include: 1. [illegible] a. SEMAGLUTIDE 1MG, B12 0.5/ML, Lot 0002-100925-A, BUD 1/17/2026 b. SEMAGLUTIDE 1MG, B12 0.5MG/ML, Lot 0002-100925-A c. SEMAGLUTIDE 4MG, B12 0.5MG/ML, Lot 0003-100925-A d. SEMAGLUTIDE 6MG, B12 0.5MG/ML, Lot 0004-100925-A e. BPC-157 3mg/mL, Lot 019-100925-A f. BPC157/TB500/KPV 3/3/3MG/ML (NO COPPER), Lot 0021-100925-A, BUD 1/17/2026 g. GHK-CU 10mg/mL, Lot 0027-100925-A, BUD 1/17/2026 h. BPC, TB500, KPV 3mg/3mg/3mg/mL, Lot 0021-100925-A i. BPC-157 3mg/mL, Lot 0019-100925-A j. TIRZEPATIDE 10MG, B12 0.5/ML, Lot 0007-100925-A k. TESMORELIN, IPAMORELIN-3MG/2MG/ML, Lot 0038-100925-A, BUD 1/17/2026 2. 12/11/2025: ISO 5 (b)(4) Buffer Hood - 1CFU; Compounded sterile product include; a. TIRZEPITIDE 15MG, B12 0.5/ML, Lot 0008-121125-1 b. TIRZEPATIDE 30MG, B12 0.5/ML, Lot 0011-121125-1, BUD 3/21/2026 c. TIRZEPITIDE 25MG, B12 0.5/ML, Lot 0010-121125-1 d. TIRZEPITIDE 20MG, B12 0.5/ML, Lot 0009-121125-1 e. Glutathione 200mg/mL, Lot 0060-121125-1, BUD 3/21/2026 f. TIRZEPATIDE 10MG, B12 0.5/ML, Lot 0007-121125-1 g. SEMAGLUTIDE 2MG, B12 0.5MG/ML, Lot 0002-121125-1 h. SEMAGLUTIDE 4MG, B12 0.5MG/ML, Lot 0003-121125-1 i. SEMAGLUTIDE 10MG, B12 0.5MG/ML, Lot 0005-121125-2 j. SEMAGLUTIDE 10MG, B12 0.5MG/ML, Lot 0005-121125-1 k. SEMAGLUTIDE 6MG, B12 0.5MG/ML, Lot 0004-121125-1 l. TIRZEPATIDE 5MG, B12 0.5/ML, Lot 0006-121125-1 m. SEMAGLUTIDE 1MG, B12 0.5MG/ML, Lot 0001-121125-1 n. SEMAGLUTIDE 10MG, GLYCINE 0.5MG/ML, Lot 0065-121125-1, BUD 3/21/2026 Your firm failed to document any action or initiate an investigation into identifying the root cause and or microbial type. B. During a review of your firm's 2025-2026 ISO 5 LAFC EM contact surface sampling for each batch, the following deficiencies were found: I found a total of nine (9) different occurrences, where contact surface samples were reported as 1 CFU or greater within ISO Classified Cleanroom Suite with all batches released and dispensed with no investigations included (surface sampling Acceptance Limits (ISO Class 5: 1. 11/12/25 12:26pm: Sema 10mg, Lot 0005-111225-2 (1 CFU) 2. 11/12/25 12:54pm: Sema 6mg, Lot 0004-111225-1 (2 CFUs) 3. 11/14/25 12:09pm: Sema 1mg, Lot 0001-111425-1 (1 CFU) 4. 11/24/25 6:11pm: Tirzep 15, Lot 0008-112425-1 (1CFU) 5. 11/25/25 10:50am, Tirzep 20, Lot 0009-112525-1 (1CFU) 6. 11/25/25 11:59am, Tirzep 15, Lot 0011-112525-1 (1CFU) 7. 12/02/25 10:07am, Trizep 15mg, Lot 0008-120225-1 (1 CFU) 8. 12/04/25 9:56am: Sema 10mg, Lot 0065-120425-1 (2 CFUs) 9. 12/26/25 1:12pm: GHKCU/Epi/cjc, Lot 0042-122625-1; your firm failed to report laboratory sample results. I found your firm failed to consistently report sample results in support of reporting passing/fail for the acceptance of designated batches compounded from December 2025 to August 2026. No investigation was carried out for any of the batches where CFUs were reported. C. Your firm defined ISO 5 laminar air flow cabinet (LAFC) action limits at less than CFU instead of 1 CFU. D. I found during my review of your firm's Cleanroom Recertification Report Collection date 3/18/2026 that 2 different contact EM surface sample locations within the ISO 5 LAFC within ISO Classified Cleanroom Suite were collected per unit. I found your firm's certifier results reported for CRLAF (b)(4) Work surface reported 3 CFUs/plate. The organism was identified as being Coag-negative Staphylococcus species. The second sample collected within the same but different sample location work surface reported a 1 CFU/plate, with the same organism being identified. Your firm documente
Shortened here; the PDF has the full text.
- 4
Blocked first air during aseptic manipulation
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted. Specifically, during compounding observations of your firm's technicians, I observed your firm's technicians reaching over open vials while filling and stoppering filled sterile vials using their sterile gloved hands in the processing of sterile finished drug products, Tirzepatide 30mg/B12 0.5mg/mL (2.4mL) 30mg/0.5mg mg/mL, Lot number 0011081726-1 BUD 2026-11-25; and Semaglutide 10mg/B12 0.5mg/mL (1.3mL) 10mg/0.5mg, Lot number 0005081726-1, BUD 2026-11-25 having the potential of blocking first air within the ISO 5 LAFC. The rubber stoppers were removed from a non-sterile (b)(4) bag that were originally stored in the approved supplier's sterile packaging.
- 5
Frequent pressure reversals without investigation
A pattern of frequent or acute pressure reversals was observed from areas of less clean air to areas of higher air cleanliness. Specifically, during a review of your firm's 2026 (b)(4) ISO Classified Cleanroom differential pressure monitoring logs approved by the firm's pharmacist for Cleanrooms Suites (b)(4), I found differential pressure reversals that occurred in the following months for Cleanroom a. February 2026 (18 out 22 Differential pressures equal; 1 missing data for Garbing Rooms; 1 pressure reversals) b. March 2026 (17 out of 24 Differential pressures equal; 6 pressure reversals) c. April 2026 (20 out of 25 Differential pressures equal; 1 missing data for (b)(4) & Garbing Rooms; 1 pressure reversals) d. May 2026 (22 out of 27 Differential pressures equal; 1 missing data for Clean Room; pressure reversals) e. June 2026 (16 out of 19 Differential pressures equal; 1 missing data for (b)(4) & Garbing Rooms; 2 pressure reversals) f. July 2026 (4 out of 19 Differential pressures equal; 2 missing data for Clean Rooms; & 7 pressure reversals) Your firm's PIC reported no investigations or hold activities were performed on any drug products compounded on the days the reversal occurred. Cleanroom ISO 7 Buffer Room contains 2 ISO 5 LAFCs used in the compounding of sterile drug products. Cleanroom Suite has been operational since February 2026.
- 6
Open vents allowing lesser quality air influx
The facility design was observed to allow the influx of lesser quality air into a classified area containing higher quality air. Specifically, A. Your firm was found to be using 2 separate modular ISO classified cleanrooms designed with open vents existing into non-controlled/non-classified areas of the facility. I found ISO 8 Anteroom for Suite vent appeared to contain white foreign particulates in the flow path. The vent was being held open using a yellow/black handle screwdriver, which was on the opposite side of the ISO 8 Anteroom Cleanroom for Cleanroom Suite. Your firm's Compounding Manager reported that the contract cleanroom certifier had used the screwdriver to hold open the vent during an issue with balancing the ISO 8 Anteroom differential pressure. B. I found what appeared to be white foreign particulates on the floor within your firm's ISO 8 gowning room of Cleanroom Suite along with the vent remaining in the open position directly in front of the outside shoe storage rack.
- 7
Rapid movement disrupting unidirectional airflow
Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, I found during aseptic processing involving stoppering and capping using sterile gloves, your firm's technicians were using a (b)(4) disrupting unidirectional airflow within (b)(4) ISO 5 LAFC units within Cleanroom Suites (b)(4) during the processing of sterile drug products, Tirzepatide 30mg/B12 0.5mg/mL (2.4mL) 30mg/0.5mg mg/mL, Lot number 0011081726-1 BUD 2026-11-25; and Semaglutide 10mg/B12 0.5mg/mL (1.3mL) 10mg/0.5mg, Lot number 0005081726-1, BUD 2026-11-25.
- 8
Infrequent glove change and sanitization
Personnel infrequently changed and sanitized gloves to prevent contamination. Specifically, your firm's technician was observed pushing trash into trashcan using their sterile gloves without performing a sterile glove change afterward. The technician disinfected their gloves and
- 9
Failure to disinfect supplies between classified areas
Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air. Specifically, A. Your firm's technician was observed failing to disinfect components located within the ISO 7 Buffer Rooms (b)(4) prior to placing them into the ISO 5 LAFC unit. B. Your firm's technicians in both ISO 7 Buffer Rooms suites during the aseptic processing of the sterile drug products, Tirzepatide 30mg/B12 0.5mg/mL (2.4mL) 30mg/0.5mg mg/mL, Lot number 0011081726-1 BUD 2026-11-25; and Semaglutide 10mg/B12 0.5mg/mL (1.3mL) 10mg/0.5mg, Lot number 0005081726-1, BUD 2026-11-25, was observed transferring stoppered trays of vials from LAFC (ISO 5 filling LAFC) through the ISO 7 Buffer Room, and into ISO 5 LAFC (ISO 5 LAFC capping and crimping) without disinfecting the trays. C. I observed your firm's technicians transferring sterile stoppers and metal caps from their original sterile packaging and into a non-sterile plastic (b)(4) storage bag within the same ISO 5 LAFC units used for aseptic processing, disrupting unidirectional airflow. The non-sterile (b)(4) bags remained in the ISO 5 LAFC for use during the aseptic stoppering and capping process step.
- 10
Inadequate sterilization process testing controls
Inadequate testing on (b)(4) used to sterilize drug products. Specifically, during a review of your firm's (b)(4) test of (b)(4) used in the compounding of finished drug sterile products, your firm failed to use calibrated gauge(s) and equipment to ensure adequate testing and (b)(4) were capable of meeting their intended use.
- 11
Unverified glassware endotoxin control and storage
Compounding with components, containers or other materials that have not been verified to assure that they do not contribute endotoxin contamination that may be objectionable given the product's intended use. Specifically, your firm fail to (b)(4) glass beakers used in the formulation of bulk non-sterile drug products that undergo sterile (b)(4) to render bulk product sterile. Your firm's management reported that glassware is (b)(4), rinsed with, and wiped with sterile (b)(4) prior to use. Your firm's cleanroom manager reported a (b)(4) has been purchased for the processing of glassware. I found your firm's washed glassware used in the formulation and compounding of bulk non-sterile drug products are stored on a wire shelf in a non-controlled non-classified area directly in front of the entry door of the facility. The glassware is positioned (b)(4) on the rack with no covering over the opening of the glassware.
- 12
Inadequate worst-case media fill simulation
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, your firm failed to provide adequate rational evidence in support that media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.
- 13
Improper sterile gowning and gloving technique
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, on 8/19/2026, two (2) technicians were observed donning their sterile gowns to enter the ISO 7 Cleanroom to start aseptic processing. Sterile gowns worn by both technicians contacted the floor while donning rendering the gowns non-sterile. Additionally, poor sterile gloving techniques were found inadequate by the technicians contacting the non-sterile side of the glove using the sterile fingers of the opposite sterile glove.
- 14
No dynamic smoke studies performed
Smoke studies were not performed under dynamic conditions. Specifically, A. Your firm's PIC and cleanroom manager, reported that they neither received, reviewed, nor approved any static or dynamic smoke studies for either Cleanroom Suites (b)(4) following (b)(4) original certifications or recertifications since the firm began operating in June 2025 for the cleanrooms. B. Your firm's compounding manager reported that no smoke studies during media fills were performed to assess laminar air flow conditions within any of the ISO 5 LAFCs, during aseptic manipulations and interventions to determine impact on finished sterile drug products.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.