Houston Rx LLC Form 483, August 2026

FDA issued this Form 483 to Houston Rx LLC in Texas (FEI 3045022201) at the end of an inspection that ended August 28, 2026. It lists 14 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 1, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 28, 2026
—
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Oct 1, 2026
34 days after the inspection
Facility
FEI 3045022201
Texas

The 14 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Exposed skin during aseptic manipulation

    Personnel performed aseptic manipulations with exposed hair or skin. Specifically, on August 24, 2026, while filling/stoppering lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL, we observed one of the operators working in the ISO 5 laminar flow hood with exposed skin on her forehead. The operator was observed entering the ISO 5 LFH, leaning over the bag of sterilized stoppers within the ISO 5 LFH, and placing stoppers on the recently filled vials.

  2. 2

    Negative pressure reversals ISO 7 to ISO 8

    A pattern of frequent or acute pressure reversals was observed from areas of less clean air to areas of higher air cleanliness. Specifically, from July 10, 2026 to August 21, 2026, your system for measuring pressure differential in the cleanrooms indicates negative pressure between the ISO 7 Buffer Room where the ISO 5 Laminar Flow Hoods are located and the ISO 8 Ante Room. The specification is (b)(4) w.c. and every data point documented in this time period was below 0.00" w.c. Your firm has made at least (b)(4) lots of various drug products in this time period. All have been released.

  3. 3

    Inadequate sterilization filter integrity testing

    Inadequate (b)(4) testing on (b)(4) used to sterilize drug products. Specifically, your firm is not conducting (b)(4) testing ((b)(4)) appropriately as recommended by the (b)(4) manufacturer. Your firm has not identified an appropriate (b)(4), you attach (b)(4) agent and you do not (b)(4) the (b)(4) before testing. [illegible] to one end of the (b)(4) and attach the other end of the (b)(4) to a (b)(4). You [illegible] the (b)(4) in (b)(4) (b)(4) from the (b)(4) through the (b)(4) and look for [illegible] then (b)(4) testing of the [illegible]. On August 24, we watched (b)(4) (b)(4) used in preparation performed in [illegible] manner. [illegible] August 24, we watched lot #SMN-082426-[illegible] of Semaglutide/Niacinamide 5mg/2mg/1mL. (b)(4) on (b)(4) the [illegible] in the [illegible].

  4. 4

    Manual contact with sterile stoppers surfaces

    Personnel were observed manually contacting the inner surface of a sterile container or closure and manually touching a sterile product contact surface. Specifically, on August 24, 2026, we watched the filling and stoppering of lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL. Your practice is to place the sterile stoppers onto the filled vials using (b)(4) and then pressing down on the stoppers with your (b)(4) to push the stopper into the vial.

  5. 5

    ISO 5 microbial contamination without investigation

    Microbial contamination was present in the ISO 5 area. On August 3, 2026, your firm recovered 1 CFU in the ISO 5 Laminar Flow Hood (b)(4) (viable surface sample) after the filling/stoppering of lot #TZN-080326-20/2-2 of Tirzepatide/Niacinamide 20/2 mg/mL (2mL vial). No investigation was performed as your firm's action level for ISO 5 areas is (b)(4) CFU, which is not appropriate. The lot was released and has been partially distributed.

  6. 6

    Poor facility design for personnel flow

    The facility is designed and/or operated in a way that permits poor flow of personnel or materials. Specifically, technicians enter the ISO 8 cleanroom area via a door from the unclassified (b)(4) area. Gowning occurs in the ISO 8 area, including washing of hands, on the "clean" side of the demarcation line. There is no designated room or area for gowning. Employees who are gowned and not gowned can interact in the same space while gowning. After formulation, those employees will then enter the ISO 7 cleanroom and work in the ISO 5 hood preparing sterile drug products without changing their garb except for their sterile gloves.

  7. 7

    Sterile drugs exposed to sub-ISO 5 air

    Sterile drugs were exposed to lower than ISO 5 quality air. Specifically, on August 24, 2026, we watched the filling and stoppering of lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL. Your practice is to place the sterile stoppers onto the filled vials using (b)(4) and then pressing down on the stoppers with your (b)(4) to push the stopper into the vial. You then (b)(4) of the vials with (b)(4) (b)(4) the (b)(4) and take them out of the cleanroom. They may be stored overnight in the (b)(4). (b)(4) of the vials, which is the final step to finish the closing of the vials, occurs in the unclassified area of the (b)(4).

  8. 8

    Media fills do not simulate worst-case production

    Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, typical batch sizes for Semaglutide/Niacinamide and Tirzepatide/Niacinamide drug products are (b)(4) vials. Vial sizes can range from 1mL to 5mL for GLP1 products and up to 10mL for other drug products. Production includes (b)(4) the drug product into a sterile (b)(4), and then manually filling vials from the (b)(4) of (b)(4) drug product using a (b)(4) placing stoppers on the vials. During a media fill, per your Quality Assurance/Compliance Pharmacy Technician, your firm fills (b)(4) vials. Your firm takes prepared media from a vial, draws it into a (b)(4), and then fills the vials using the (b)(4). Your firm also does not document the number of vials filled, incubated and read in the paperwork for the media fills.

  9. 9

    Non-pharmaceutical grade ingredients in sterile drugs

    Use of ingredients not intended for pharmaceutical use in sterile drug production. Specifically, your firm is using active pharmaceutical ingredients and excipients that are not always USP/NF grade or are non-pharmaceutical grade. For example, a) The Certificate of Analysis (CoA) for lot #(b)(4) of Methylcobalamin states "For R&D only". Your firm has made approximately (b)(4) lots of Methylcobalamin 5mg/mL using lot #(b)(4). b) The CoA for lot #(b)(4) of Tirzepatide states it is for "R&D only". Your firm has made approximately (b)(4) lots of Tirzepatide/Niacinamide 10/2 mg/mL and 4 lots of Tirzepatide/Niacinamide 20/2 mg/mL using lot #(b)(4) of Tirzepatide. c) The CoA for lot #(b)(4) of Sermorelin states "This product is intended for scientific research use only". Your firm has made approximately (b)(4) lots of Sermorelin 1mg/mL using lot #(b)(4). d) The CoA for lot #(b)(4) of Semaglutide API states it is for "R&D only". Your firm has made at least (b)(4) lots of Semaglutide/Niacinamide 2.5/2 mg/mL and (b)(4) lots of Semaglutide/Niacinamide 5/2 mg/mL using lot #(b)(4). e) The CoA for lot #(b)(4) of Nicotinamide Adenine Dinucleotide+ (NAD+) states "For Laboratory Use Only!". Your firm has made at least (b)(4) of Nicotinamide Adenine Dinucleotide+ 100 mg/mL using (b)(4). f) The CoA for lot #(b)(4) of Niacinamide, USP is not pharmaceutical grade as the USP monograph is a dietary supplement monograph. Your firm uses niacinamide in all GLP1 formulations and has used this specific lot to make all Semaglutide/Niacinamide and Tirzepatide/Niacinamide for at least the last (b)(4) months.

  10. 10

    Moldy dripping vent adjacent to cleanroom

    Contamination was observed in your areas adjacent to production areas. Specifically, a ceiling vent just outside the cleanroom has water stains and what appears to be mold. On August 24, 2026, the vent was dripping condensate near the area where items to be taken into the cleanroom were wiped down for use in making lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL.

  11. 11

    Residue-leaving cleaners on product contact equipment

    Use of cleaning and disinfecting agents that may leave residues or not adequately rinsing such agents from containers, closures, or equipment that come into direct contact with drug products. Specifically, your firm uses (b)(4) and tap water to wash equipment used to make sterile drug products, including glass beakers, stir bars, and graduated cylinders. Your firm rinses the equipment with (b)(4) sterile water and then wipes the beakers and stir bars with (b)(4). There is no wiping down of the inside of the graduated cylinders with (b)(4). The graduated cylinders are used to measure out liquids such as the sterile water used during the production of sterile drug products. On August 24, 2026, we watched the cleaning of equipment to be used in the making of lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL, using this process.

  12. 12

    Non-sterile equipment used for sterile products

    Sterile products were exposed to non-sterile or non-depyrogenated supplies. Specifically, your firm does not sterilize/depyrogenate the glass beakers, (b)(4) graduated cylinders, and stir bars used to make sterile drug products. On August 24, 2026, we watched the preparation of lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL. The glass beakers, (b)(4) graduated cylinders and stir bars were not sterilized/depyrogenated before use.

  13. 13

    No biological indicators for sterilization verification

    Biological indicators were not used to verify the adequacy of the sterilization cycle. Specifically, your firm has not validated nor do you use a biological indicator (BI) when (b)(4) the (b)(4) and (b)(4) used in the preparation of sterile drug products. The (b)(4) are used to place sterile stoppers onto the filled vials. (b)(4) are used to (b)(4) the (b)(4) of sterile water used in the formulation of sterile drug products.

  14. 14

    APIs not stored per labeled conditions

    Your firm is not storing active pharmaceutical ingredients (API) per the labeled storage conditions. All APIs are stored in a (b)(4) refrigerator. Examples of APIs used in the production of sterile drug products that are not stored according to the labeled storage conditions include the following. Sterile drug products made with these APIs have been released and distributed. a) The CoA for lot #(b)(4) of Semaglutide API states to store at (b)(4). Your firm has made at least (b)(4) lots of Semaglutide/Niacinamide 2.5/2 mg/mL and (b)(4) lots of Semaglutide/Niacinamide 5/2 mg/mL using lot #(b)(4). b) The CoA for lot #(b)(4) of Tirzepatide API states to store at (b)(4). Your firm has made approximately (b)(4) lots of Tirzepatide/Niacinamide 10/2 mg/mL and (b)(4) lots of Tirzepatide/Niacinamide 20/2 mg/mL using lot #(b)(4) of Tirzepatide. c) The CoA for lot #(b)(4) of Tirzepatide API states to store at (b)(4). d) The CoA for lot #(b)(4) of Sermorelin API states to store at (b)(4). e) The CoA for lot #(b)(4) of Nicotinamide Adenine Dinucleotide+ (NAD+) states to store in (b)(4). Your firm has made at least (b)(4) of Nicotinamide Adenine Dinucleotide+ 100 mg/mL using (b)(4).

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.