Buildings, facilities and HVAC in FDA Form 483 observations
The plant itself: building design and repair, air handling, pressure differentials, temperature and humidity. FDAgent finds 160 such observations in 121 Form 483s issued to 117 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 160
- Each quoted below
- Form 483s
- 121
- Posted by FDA
- Facilities
- 117
- Distinct FEIs
- Most recent
- Sep 10, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 49 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 1 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 1 |
| 2013 | 1 |
| 2014 | 8 |
| 2015 | 7 |
| 2016 | 4 |
| 2017 | 6 |
| 2018 | 9 |
| 2019 | 9 |
| 2020 | 2 |
| 2021 | 8 |
| 2022 | 15 |
| 2023 | 8 |
| 2024 | 18 |
| 2025 | 13 |
| 2026 | 49 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.4221 CFR 211.4421 CFR 211.4621 CFR 211.4821 CFR 211.5021 CFR 211.5221 CFR 211.58
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“HVAC” · “air handl*” · “AHU*” · “pressure differential*” · “differential pressure*” · “temperature and humidity” · “humidity control*” · “humidity monitor*” · “air change*” · “air filtration” · “state of repair” · “ceiling tile*” · “peeling” · “flaking” · “water leak*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 160 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 3
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. The firm's environmental monitoring and personnel monitoring procedures are inadequate. For example: 1. Your firm failed to analyze raw Environmental Monitoring data for patterns (e.g., increasing CFUs) that indicate a loss of control in aseptic areas. Data trending is not performed and compiled (b)(4) in accordance with …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Almon Healthcare Private LimitedInspection ended Feb 13, 2026 · FEI 3030509366 · Observation 5
… Additionally, it was also noted that your firm turned the air handling unit (AHU) on and off based on production activities. According to your Executive QA, a minimum of (b)(4) is required to recover the ISO 8 (Class D) condition. However, the recovery time was not mentioned in the test report. APIs, including (b)(4) inside this room, shipped to the US market were (b)(4). c. The following areas in the cleanroom facility for processing and packing …
Contains “air handl*”Read the Form 483 →
Biomylz Private LimitedInspection ended Feb 9, 2026 · FEI 3013697420 · Observation 6
Your firm failed to maintain buildings used in the manufacture, processing, packing, or holding of drug products in a good state of repair. On February 4, 2026, during the initial inspectional walkthrough of your facility, we observed that the valve (b)(4) of your (b)(4) system was leaking from the bottom and at the (b)(4) piping connection. Your firm did not perform any corrective actions to repair the (b)(4) at the time of the inspection. …
Contains “state of repair”Read the Form 483 →
SNJ Labs Private Ltd.Inspection ended Feb 6, 2026 · FEI 3026587575 · Observation 4
… Clean room (b) (4) Plant (b) showed (b) (4) material spots on the ceiling (approximately (b) (4) above the (b) (4) Floors had stains and peeling seals between the floor and wall behind the (b) (4) Room corners near the ceiling showed dust-like material and cracks on February 2, 2026. The (b) (4) cleaning record showed that the room was last cleaned on (b) (4) and there was no documentation on the logbook for (b) (4) cleaning of ceiling. b. Clean …
Contains “peeling”Read the Form 483 →
Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 3
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Your firm does not have a risk assessment to justify the environmental monitoring and personal monitoring locations and frequencies. 1. There is no surface monitoring on the Grade A aseptic filling line. ge used to fill the ge drug. While reviewing machine set up of the media fill dated September 15, 2025, and while observing …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 11
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair. Specifically, On 01/21/2026, visible damage and black/brown stains were observed on the HEPA filters on the ceiling in Compression Room ^(b) (4) above the ^(b) (4) Tooling Tablet Press (b) (4) which was used to compress (b) (4) tablets Lot #(b) (4). No preventative maintenance program exists for the HEPA filters.
Opens with FDA's citation wording for 21 CFR 211.58Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 2
… been documented as work orders without a corresponding deviation: Work Order Number 3296872 Opened January 09, 2025 Description "Investigation/Actions - A water leak was identified on the (b) (4) (b) (4) On investigation it was found that the (b) (4) was found to not be (b) (4) and was leaking." Work Order Number 3296870 Opened January 09, 2025 Description "Investigation/Actions - Water was visible on the ground at the (b) (4) (b) (4) On …
Contains “water leak*”Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 3
Buildings used in the manufacturing, processing and holding of a drug product are not maintained in a good state of repair. Specifically, the following conditions were observed in your fill/finish manufacturing areas during the current inspection: A) On January 13, 2026, in Room (b) (4) (Fill Line (b) (4)) the (b) (4) exhibited two "X" shaped cracks that were actively extruding water during the (b) (4) operations utilizing (b) (4) The …
Opens with FDA's citation wording for 21 CFR 211.58Read the Form 483 →
US Specialty Formulations LLCInspection ended Jan 14, 2026 · FEI 3010680515 · Observation 3
… The stability sam temperature and humidity control and therefore are
Contains “temperature and humidity”Read the Form 483 →
Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 5
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. A. Personnel monitoring program has not been implemented for any aseptic operations. Personnel monitoring regarding aseptic connections has never been conducted. B. Surface monitoring has never been performed on any equipment surfaces including critical product contact surfaces such as (b)(4) product contact locations including (b)(4). C. Active …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 6
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, Your firm lacked adequate justification for washing and sterilizing (b)(4) gloves only To (b)(4) is used. Also, (b)(4) is used as needed and (b)(4) (a sporicide) is used (b)(4). However, there is no written procedure on how to clean (b)(4) gloves. You also have no study to monitor cleaning …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →
Sun Pharmaceuticals Medicare Ltd.Inspection ended Sep 19, 2025 · FEI 3002957541 · Observation 2
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. During review of the environmental and personnel monitoring (EM and PM), the following was noted: A. From 01/2023 to date, a total of (4) batches were rejected due to EM or PM excursions. (4) of the rejections involved manufacturing Block (b)(4) PM excursions (Action limits for Grade A: (b)(4) Grade B: (4) cfu/plate or NMT (b)(4) cfu (b)(4) gown …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Hikma Injectables USA Inc.Inspection ended Aug 8, 2025 · FEI 3022897129 · Observation 3
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, The firm's procedure for collecting active viable air within the ISO-5 laminar airflow hood is not representative of the full duration of the sterile production process. The firm will only collect [illegible] of air within approximately [illegible] and that the production process within the laminar airflow hood lasts approximately …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 2
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, A. I observed apparent white colored residue and apparent brown or red colored stains on your work surfaces in your ISO 5 hood. The apparent white colored residue is also apparent throughout your ISO 5 environment affecting approximately all hoods. The design with the approximate of your working …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →
Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 3
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient. Specifically, A. The design of your facility allows for operations to include material flows directly between unclassified areas and your ISO 7 sterile compounding room, "Room [illegible]". Specifically, materials flow from your non-classified "Prep Room" to your ISO 7 compounding room, "Room [illegible]" and from "Room [illegible]" to …
Opens with FDA's citation wording for 21 CFR 211.42(c)Read the Form 483 →
Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 4
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Personnel and environmental monitoring during and after your aseptic connection as well as throughout aseptic production is not scientifically performed. 1. The system by which you conduct personnel monitoring is not scientifically established. I observed personnel enter your ISO 5 environment with their hands and arms. You do not …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Nanjing Cuccess Pharmaceutical Co., LtdInspection ended Mar 21, 2025 · FEI 3027129265 · Observation 2
… chamber requalification protocol VP1026-24-01-00 and report VR1026-24-01-00 indicate the chamber must be in a full load configuration prior to initiating the temperature and humidity mapping for. Validation personnel confirmed they added large boxes to the chamber to fill the shelves before the most recent qualification in about June 2024. Your firm did not provide written scientific justification to add non-stability study materials to the …
Contains “temperature and humidity”Read the Form 483 →
Emcure Pharmaceuticals LimitedInspection ended Feb 25, 2025 · FEI 3005782879 · Observation 1
… Maintenance and Equipment Integrity Issues: (b)(4) showed physical deterioration (paint chips, rust, peeling) and [illegible] maintenance "KEM-008/06, Preventive Maintenance for [illegible] (b)(4) Effective Date: 06 Aug 2024" did not require inspection for such damage. (b)(4) with numerous [illegible] and (b)(4) #1402 had (b)(4) dents; cleaning validation did not address potential residue in hard-to-clean areas nor incorporate dent study results.
Contains “peeling”Read the Form 483 →
Shouguang Fukang Pharmaceutical Co., Ltd.Inspection ended Feb 21, 2025 · FEI 3003941038 · Observation 9
Adequate lighting is not provided in all areas. Specifically, on 2/17/2025, inspection of the firm's raw material warehouse (b)(1) where raw materials for the API (b)(1) and (b)(1) are stored noted dim lighting conditions in this warehouse. These conditions hinder the proper monitoring of raw materials stored in this warehouse such as for temperature/humidity monitoring and identification of stored raw materials.
Opens with FDA's citation wording for 21 CFR 211.44Read the Form 483 →
Glenmark Pharmaceuticals Ltd.Inspection ended Feb 14, 2025 · FEI 3008565058 · Observation 2
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Separate or defined areas to prevent contamination are deficient re (bf(\.l ,.l.. mg products (CbH Tablets) at your facility. For example: A. You failed to ensure sampling, dispensing, [and] [illegible] for (6) (CbH Tablets) are carried out using dedicated [illegible] systems. For example: • Sampling areas, equipment, …
Opens with FDA's citation wording for 21 CFR 211.42(c)(5)Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.42Design and construction featuresIn this theme's rule60
- 21 CFR 211.58MaintenanceIn this theme's rule8
- 21 CFR 211.22Responsibilities of quality control unit4
- 21 CFR 211.113Control of microbiological contamination4
- 21 CFR 211.192Production record review4
- 21 CFR 211.44LightingIn this theme's rule1
- 21 CFR 211.52Washing and toilet facilitiesIn this theme's rule1
- 21 CFR 211.56Sanitation1
- 21 CFR 211.63Equipment design, size, and location1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1
Ask FDAgent about facilities and HVAC in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.