Skip to content

Biomylz Private Limited Form 483, February 2026

FDA issued this Form 483 to Biomylz Private Limited in Bengaluru, India (FEI 3013697420) at the end of a drug inspection that ended February 9, 2026. It lists 7 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on July 13, 2026.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 22, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 9, 2026
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Oct 22, 2026
255 days after the inspection
Facility
FEI 3013697420
Bengaluru, India

The 7 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Failure to investigate data integrity breaches

    Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed. On January 22, 2026, your firm terminated the former Plant Manager due to repeated and ongoing data integrity violations, including, but not limited to, destruction of batch production records, destruction of laboratory-controlled records, and documentation of false production and laboratory data. According to your Quality Head, employees working in the production and laboratory areas were instructed by the former Plant Manager to destroy, alter, or manipulate records and felt compelled to comply due to his supervisory authority. This inadequate practice was also observed and confirmed by your Operations Manager to whom the former Plant Manager reported to. Despite these identified data integrity concerns, your firm did not initiate an investigation or conduct a comprehensive evaluation of manufacturing and laboratory records associated with OTC drug products manufactured for the U.S. market to determine the extent and impact of the data integrity breaches. In addition, your firm did not perform reconciliation of incoming raw materials, finished drug products manufactured and released, inventory records, equipment usage logbooks, laboratory test results, sample collection records, or batch production records to determine whether additional discrepancies or undocumented activities occurred. In addition, your firm did not implement interim controls to prevent recurrence of data integrity failures. The former Plant Manager oversaw production operations from June 2019 through January 2026. Since March 2024, your firm has manufactured (b)(4) lots of (b)(4) intended for the U.S. market, all of which remain within their expiration dates. Moreover, on February 4, 2026, during the initial inspectional walkthrough of your facility, the following data integrity deficiencies were observed: A. Destroyed controlled records containing raw data were observed inside a trash bag located in the scrap room. The recovered documents included, but were not limited to, executed production batch records; media preparation, incubation, and sterilization cycle logbook pages; finished product sample collection forms; environmental monitoring sample forms; and change control log forms. B. The Incubation Usage Log, Book Number (b)(4) Reference SOP: QCD-M/007 & III, contained (b)(4) entries (Serial Numbers (b)(4) through (b)(4)) that were signed by the analyst (QC Microbiologist) and verified by a second person (QC Chemist) despite incubation end date not being reported. C. Controlled documents issued by Quality Assurance were not adequately controlled or reconciled. Specifically, your firm did not perform document retrieval as required by logbook (Book Number: (b)(4) titled "Formats/Document Issuance & Retrieval Log", Reference SOP: QAD/004 II, to ensure that all controlled printed copies were returned to Quality Assurance and reconciled. D. The Media Preparation Sterilization and Weight Balance Log, Book Number (b)(4) Reference SOP: QCD-M/001 & I), contained (b)(4) media volume entries recorded in pencil rather than permanent ink. According to the analyst, entries were initially recorded in pencil and later overwritten in ink after completion of weight checks. These entries were signed (QC Microbiologist) and verified by a second person (QC Chemist) despite media weight not being reported and media volume documented in pencil. E. Laboratory logbooks used to document media preparation, pH meter equipment usage, incubator usage, sterilization (b)(4) activities, conductivity meter calibration, and pH meter calibration were observed with pages that were not numbered in advance. As a result, there is no assurance that pages cannot be removed, replaced, or altered without detection, and that laboratory records are complete and reliable.

  2. 2

    No process validation and stability procedures

    There are no written procedures for production and process controls designed to assure that the OTC products have the identity, strength, quality and purity they purport or are represented to possess. A. For example, your firm has not performed the process validation for (b)(4) OTC product. Nevertheless, your firm has been releasing (b)(4) commercial batches (i.e., (b)(4) Exp Date respectively) to be distributed in the USA market. B. Your firm has not established stability studies for (b)(4) OTC products distributed to the U.S. market. Specifically, firm management assigned a (b)(4) expiration date for (b)(4) OTC products. However, your firm lacks supporting stability data or other scientifically sound evidence to demonstrate that these products will meet established quality attributes throughout their shelf life.

  3. 3

    Incomplete laboratory records missing raw data

    Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Your firm failed to maintain complete laboratory records, including raw data, for laboratory analyses conducted on commercial drug products. Specifically, raw data supporting laboratory test results used to release commercial batches, to validate the commercial manufacturing process, and/or in house (b)(4) system were not retained or were unavailable for review.

  4. 4

    Quality unit responsibilities not fully followed

    The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, A. There is no assurance that laboratory testing used to determine raw material suitability and finished drug product quality is performed in accordance with applicable cGMP requirements. For example, your firm uses contracted laboratories that are not registered or inspected by the agency to perform incoming raw material and finished OTC drug product testing, including the Certificate of Analysis (CoA) used to support the release decision. In addition, no Quality Agreements have been established between your firm and the contracted laboratories to define roles, responsibilities, and oversight related to testing, data integrity, and compliance with cGMP requirements. Moreover, no documented evidence was provided, which demonstrates that the selected contracted laboratories have been inspected by your Quality Unit to assess their compliance with applicable cGMP requirements. B. A quality agreement has not been established between your firm and the owner of the U.S.-marketed (b)(4) OTC product. As a result, there is no assurance that effective quality systems and controls are consistently implemented, as the roles and responsibilities of each party involved in contract manufacturing, packaging, testing, release, and post-distribution quality activities are not clearly defined. These deficiencies may adversely affect your firm's ability to adequately oversee cGMP activities and to promptly identify, investigate, and address potential quality issues affecting products distributed to the U.S. market. C. Your firm was unable to provide the corrective and preventive action (CAPA) reports generated by your Quality Unit in response to the seventeen (17) objectionable conditions documented in the FDA Form 483 issued during the previous inspection on July 2, 2020.

  5. 5

    No written equipment cleaning procedures

    Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, your firm failed to develop and approve cleaning procedures describing in sufficient detail the methods, equipment and materials to be used for cleaning the production equipment (i.e., (b)(4) tank, holding tank and filling line) and utensils or auxiliary equipment (e.g., transfer lines and filling hoses) used in the manufacture of your (b)(4) OTC product. As per your Quality Manager, your cleaning procedures are executed (b)(4)

  6. 6

    Facility not maintained in good repair

    Your firm failed to maintain buildings used in the manufacture, processing, packing, or holding of drug products in a good state of repair. On February 4, 2026, during the initial inspectional walkthrough of your facility, we observed that the valve (b)(4) of your (b)(4) system was leaking from the bottom and at the (b)(4) piping connection. Your firm did not perform any corrective actions to repair the (b)(4) at the time of the inspection. (b)(4) by this system is used as a raw material in the formulation of (b)(4) OTC product. In addition, (b)(4) is used as a cleaning agent for equipment and utensils (b)(4) that come into direct contact with the OTC finished product during manufacturing operations.

  7. 7

    Reserve samples not examined annually

    Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration. Specifically, according to your procedure titled "Procedure for Collection and Storage of Control Sample", SOP Number: QCD/009, Version: R04, Effective Date: April 07, 2025, Section 5.1.1 states, "The control sample shall be collected from each batch of finished goods manufactured and from each batch of raw material ingredient received". However, no examination is performed at least once a year to determine if (b)(4) product deterioration in U.S. marketed OTC products that include (b)(4) has occurred.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.