BioMylz Pvt. Ltd.
Building No.1, #21-D, 2nd Phase, Peenya Industrial Area, Bengaluru, India
FEI 3013697420DUNS 860479936
FDA has 2 inspections on file for BioMylz Pvt. Ltd. in Bengaluru, India (FEI 3013697420), from 2020 to 2026. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. Three FOIA requests have asked FDA for this inspection's 483.
4 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 66-41 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is BioMylz Pvt Ltd. (D-U-N-S 860479936).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2020–2026
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Aug 14, 2026
- Warning letters
- · CDER ↗
- Import refusals
- 4 refusals
- Import alerts
- 66-41Red List
- Matched on FDA’s firm name and street address
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate data integrity breaches
Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed. On January 22, 2026, your firm terminated the former Plant Manager due to repeated and ongoing data integrity violations, including, but not limited to, destruction of batch production records, destruction of laboratory-controlled records, and documentation of false production and laboratory data. According to your Quality Head, employees working in the production and laboratory areas were instructed by the former Plant Manager to destroy, alter, or manipulate records and felt compelled to comply due to his supervisory authority. This inadequate practice was also observed and confirmed by your Operations Manager to whom the former Plant Manager reported to. Despite these identified data integrity concerns, your firm did not initiate an investigation or conduct a comprehensive evaluation of manufacturing and laboratory records associated with OTC drug products manufactured for the U.S. market to determine the extent and impact of the data integrity breaches. In addition, your firm did not perform reconciliation of incoming raw materials, finished drug products manufactured and released, inventory records, equipment usage logbooks, laboratory test results, sample collection records, or batch production records to determine whether additional discrepancies or undocumented activities occurred. In addition, your firm did not implement interim controls to prevent recurrence of data integrity failures. The former Plant Manager oversaw production operations from June 2019 through January 2026. Since March 2024, your firm has manufactured (b)(4) lots of (b)(4) intended for the U.S. market, all of which remain within their expiration dates. Moreover, on February 4, 2026, during the initial inspectional walkthrough of your facility, the following data integrity deficiencies were observed: A. Destroyed controlled records containing raw data were observed inside a trash bag located in the scrap room. The recovered documents included, but were not limited to, executed production batch records; media preparation, incubation, and sterilization cycle logbook pages; finished product sample collection forms; environmental monitoring sample forms; and change control log forms. B. The Incubation Usage Log, Book Number (b)(4) Reference SOP: QCD-M/007 & III, contained (b)(4) entries (Serial Numbers (b)(4) through (b)(4)) that were signed by the analyst (QC Microbiologist) and verified by a second person (QC Chemist) despite incubation end date not being reported. C. Controlled documents issued by Quality Assurance were not adequately controlled or reconciled. Specifically, your firm did not perform document retrieval as required by logbook (Book Number: (b)(4) titled "Formats/Document Issuance & Retrieval Log", Reference SOP: QAD/004 II, to ensure that all controlled printed copies were returned to Quality Assurance and reconciled. D. The Media Preparation Sterilization and Weight Balance Log, Book Number (b)(4) Reference SOP: QCD-M/001 & I), contained (b)(4) media volume entries recorded in pencil rather than permanent ink. According to the analyst, entries were initially recorded in pencil and later overwritten in ink after completion of weight checks. These entries were signed (QC Microbiologist) and verified by a second person (QC Chemist) despite media weight not being reported and media volume documented in pencil. E. Laboratory logbooks used to document media preparation, pH meter equipment usage, incubator usage, sterilization (b)(4) activities, conductivity meter calibration, and pH meter calibration were observed with pages that were not numbered in advance. As a result, there is no assurance that pages cannot be removed, replaced, or altered without detection, and that laboratory records are complete and reliable.
- Observation 2
No process validation and stability procedures
There are no written procedures for production and process controls designed to assure that the OTC products have the identity, strength, quality and purity they purport or are represented to possess. A. For example, your firm has not performed the process validation for (b)(4) OTC product. Nevertheless, your firm has been releasing (b)(4) commercial batches (i.e., (b)(4) Exp Date respectively) to be distributed in the USA market. B. Your firm has not established stability studies for (b)(4) OTC products distributed to the U.S. market. Specifically, firm management assigned a (b)(4) expiration date for (b)(4) OTC products. However, your firm lacks supporting stability data or other scientifically sound evidence to demonstrate that these products will meet established quality attributes throughout their shelf life.
Show observations 3 to 7
- Observation 3
Incomplete laboratory records missing raw data
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Your firm failed to maintain complete laboratory records, including raw data, for laboratory analyses conducted on commercial drug products. Specifically, raw data supporting laboratory test results used to release commercial batches, to validate the commercial manufacturing process, and/or in house (b)(4) system were not retained or were unavailable for review.
- Observation 4
Quality unit responsibilities not fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, A. There is no assurance that laboratory testing used to determine raw material suitability and finished drug product quality is performed in accordance with applicable cGMP requirements. For example, your firm uses contracted laboratories that are not registered or inspected by the agency to perform incoming raw material and finished OTC drug product testing, including the Certificate of Analysis (CoA) used to support the release decision. In addition, no Quality Agreements have been established between your firm and the contracted laboratories to define roles, responsibilities, and oversight related to testing, data integrity, and compliance with cGMP requirements. Moreover, no documented evidence was provided, which demonstrates that the selected contracted laboratories have been inspected by your Quality Unit to assess their compliance with applicable cGMP requirements. B. A quality agreement has not been established between your firm and the owner of the U.S.-marketed (b)(4) OTC product. As a result, there is no assurance that effective quality systems and controls are consistently implemented, as the roles and responsibilities of each party involved in contract manufacturing, packaging, testing, release, and post-distribution quality activities are not clearly defined. These deficiencies may adversely affect your firm's ability to adequately oversee cGMP activities and to promptly identify, investigate, and address potential quality issues affecting products distributed to the U.S. market. C. Your firm was unable to provide the corrective and preventive action (CAPA) reports generated by your Quality Unit in response to the seventeen (17) objectionable conditions documented in the FDA Form 483 issued during the previous inspection on July 2, 2020.
- Observation 5
No written equipment cleaning procedures
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, your firm failed to develop and approve cleaning procedures describing in sufficient detail the methods, equipment and materials to be used for cleaning the production equipment (i.e., (b)(4) tank, holding tank and filling line) and utensils or auxiliary equipment (e.g., transfer lines and filling hoses) used in the manufacture of your (b)(4) OTC product. As per your Quality Manager, your cleaning procedures are executed (b)(4)
- Observation 6
Facility not maintained in good repair
Your firm failed to maintain buildings used in the manufacture, processing, packing, or holding of drug products in a good state of repair. On February 4, 2026, during the initial inspectional walkthrough of your facility, we observed that the valve (b)(4) of your (b)(4) system was leaking from the bottom and at the (b)(4) piping connection. Your firm did not perform any corrective actions to repair the (b)(4) at the time of the inspection. (b)(4) by this system is used as a raw material in the formulation of (b)(4) OTC product. In addition, (b)(4) is used as a cleaning agent for equipment and utensils (b)(4) that come into direct contact with the OTC finished product during manufacturing operations.
- Observation 7
Reserve samples not examined annually
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration. Specifically, according to your procedure titled "Procedure for Collection and Storage of Control Sample", SOP Number: QCD/009, Version: R04, Effective Date: April 07, 2025, Section 5.1.1 states, "The control sample shall be collected from each batch of finished goods manufactured and from each batch of raw material ingredient received". However, no examination is performed at least once a year to determine if (b)(4) product deterioration in U.S. marketed OTC products that include (b)(4) has occurred.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance17 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions.
Washing and toilet facilities are deficient
Washing and toilet facilities lack hot and cold water.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful and specific test methods.
Reprocessing procedures not written or followed
Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing and instructions.
Show 12 more citations
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Calibration/Inspection/Checking not done
Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Establish reliability of supplier's C of A
Establishment of the reliability of the container and closure supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Description of containers, labels, et. al.
Master production and control records lack a specimen or copy of each label and all other labeling.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Accurate reproduction included
Batch production and control records for each batch of drug product produced do not include an accurate reproduction of the appropriate master production or control record which was checked for accuracy, dated and signed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Cleaning/maintenance records not kept
Records are not kept for the maintenance, cleaning and inspection of equipment.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Aug 14, 2026. Each one asked for a Form 483.
Inspection ending Feb 9, 2026OAI
3 requests. In the inspection history above. FDA has posted its Form 483.
- Aug 14, 2026FDA-FOIA-2026-7888Form 483· 1 of 5 sitesRecords released
- May 25, 2026FDA-FOIA-2026-5261Form 483· 1 of 2 sitesRecords released
- May 25, 2026FDA-FOIA-2026-5250Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.52Washing and toilet facilities1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.111Time limitations on production1 of 1
Show all 14
- 21 CFR 211.115Reprocessing1 of 1
- 21 CFR 211.122Materials examination and usage criteria1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.186Master production and control records1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3013697420, one row per refused product line.
4 refusals from 2021-05-07 to 2024-08-22 · charged UNAPPROVED on 4 · no FDA sample analysis
FDA firm profile- 2024-08-22
EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YCY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-5632988-9/11/1
- 2024-04-24
MISCELLANEOUS PATENT MEDICINES, ETC.66VDH99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast ImportsDP4-8633726-5/11/2
- 2024-04-24
MISCELLANEOUS PATENT MEDICINES, ETC.66VDH99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast ImportsDP4-8633726-5/11/1
- 2021-05-07
ANTI-INFLAMMATORY N.E.C.62GBY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsE9G-7003293-2/11/1
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 66-41Red ListDetention Without Physical Examination of Unapproved New Drugs Promoted In The U.S.Import alert pageAlert on fda.gov
Date published 2024-04-24
- FDA’s entry
- BioMylz Pvt. Ltd. · Building No.1, #21-D, 2nd Phase, Peenya Industrial Area, Bengaluru, Karnataka INDIA
- FDA’s inspection record for FEI 3013697420
- BioMylz Pvt. Ltd. · Building No.1, #21-D, 2nd Phase, Peenya Industrial Area, Bengaluru, India
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
6 products
- 54 E - - 99Herbals & Botanical Teas, N.E.C.
- 54 E - - 99Herbals & Botanical Teas, N.E.C.
- 54 F - - 99Herbals & Botanicals (not Teas), N.E.C.
Show 3 more products
- 54 F - - 99Herbals & Botanicals (not Teas), N.E.C.
- 66 V - - 99Miscellaneous Patent Medicines, Etc.
- 66 V - - 99Miscellaneous Patent Medicines, Etc.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- BioMylz Pvt Ltd.D-U-N-S 860479936
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013697420 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013697420. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.