Skip to content

Huons Co., Ltd.

100 Bio-Valley-Ro, Jecheon, Korea (the Republic of)

FEI 3007163376DUNS 631099384

FDA has 6 inspections on file for Huons Co., Ltd. in Jecheon, Korea (the Republic of) (FEI 3007163376), from 2014 to 2025. The latest ended on and was classified NAI, no action indicated. FDA issued a warning letter on (CDER).

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

The most recent OAI inspection ended on Nov 21, 2025. 58 import refusals are filed under this FEI, the latest on . FDA’s Red Lists for Import Alerts 66-40 and 89-04 name this firm at this address. FDA printed no FEI on the entries. No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is Huons Co., Ltd. (D-U-N-S 631099384).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
6, 2014–2025
1 OAI · 4 VAI · 1 NAI
Inspections with 483 observations shown
3 of 6
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jul 1, 2026
Import refusals
58 refusals
Import alerts
66-40, 89-04Red List
Matched on FDA’s firm name and street address
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete lab records and data manipulation

      Laboratory records do not include complete data derived from all tests, examinations, and assay necessary to assure compliance with established specifications and standards. Specifically, A. During review of the bioburden and endotoxin tests performed on 11/03/2025 for the (b)(4) Line media fill (b)(4) samples, we found the following. a) The (b)(4) Tank and Tank Transfer Line samples endotoxin out of specification (OOS) results obtained on 11/03/2025 were not recorded and reported. They were later replaced with the within acceptance results from different samples by QC Microbiology Team Lead. The passing results were reported in the final certificate of analysis (COA). b) The media plates that showed alert level colony forming units (CFU) at the completion of incubation on 11/10/2025 were discarded. No worksheet was generated to document the positive bioburden data. On 11/12/2025 when inquired by the FDA investigator, the QC Microbiology Team Lead changed camera time and date to take photos of the plates with microbial growth. She also instructed a team member to create worksheets by backdating test information. B. The Incubator Usage Record logbook (INC-3127) was manipulated to remove two entries of bioburden (b)(4) samples collected for deviation investigation regarding (b)(4) sterilization in the Vial Line. The samples of concern were for Huons (b)(4) Injection (b)(4) Batch (domestic market). Specifically, on 10/31/2025 pages 60 to 62 of the logbook containing (b)(4) information of the deviation samples were removed by the QC Microbiology Team Lead. She replaced the torn out pages with blank forms and instructed a team member to backfill log information, excluding information for the deviation samples. C. During the microbiology laboratory walkthrough on 11/12/2025, over thirty (30) different uncontrolled current good manufacturing practice (CGMP) blank document form types were identified as well as forms filled with original, raw data. Each blank form could be assessable to any personnel who had access to the microbiology laboratory without any additional controls and traceability. For example, one of the documents identified was a completed endotoxin gel clot test form (Analysis No. R251020004) for the following active pharmaceutical ingredient (API), (b)(4) Batch (b)(4). According to the laboratory personnel, the person identified an issue with the weight collected for the gel clot (power of 10), and the test was redone with a new, blank form two (2) days later. The original test form was not included with the test package for the raw material, there was no deviation or quality event initiated for the event, and no one reviewed the original form (no review signature). Batch (b)(4) was released for use, and the API batch was utilized for at least batches that were intended for the U.S. Market such as (b)(4) Vials and (b)(4) Ampoule (b)(4).

    2. Observation 2

      Inadequate complaint investigations for ineffectiveness

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. Specifically, From 01/2023 to date, a total of 39 complaints from the U.S. market were received regarding (b)(4) Injection USP being ineffective. No root cause was assigned for drug ineffectiveness. (b)(4) batches In 2022, out of the total received ineffective complaints (each batch can receive multiple complaints). Additionally in 2023, out of the (b)(4) batches received complaints. (b)(4) is administered total (b)(4) batches manufactured and shipped [to] the U.S., (b)(4). Your firm's complaint investigations are inadequate in that to date no root cause(s) have been identified to assure product quality and patient safety.

    Show observations 3 to 6
    1. Observation 3

      Inadequate OOS investigations and review

      There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. The firm's OOS investigation OS-LC23-006 was inadequate. OS-LC23-006 was initiated following an OOS result for unknown substance in finished product (b)(4) Injection (b)(4) Batch (b)(4). The OOS for Batch (b)(4) found unknown purity of (b)(4) [illegible]. The firm's Phase I investigation assigned dirty glassware being the root cause. However, no scientific evidence was provided to confirm contaminated glassware was the cause for the OOS data. A new sample was tested using a "clean" glassware, the result was within acceptance, and the batch was released to the U.S. in 05/17/2023. Batch (b)(4) was manufactured in 04/05/2023 with an expiration date of (b)(4). B. The firm's OOS investigation OOS OS-LC23-010 was inadequate. OS-LC23-010 was initiated following (b)(4) impurity in (b)(4) Injection (b)(4) ml USP (b)(4) Batch (b)(4). The OOS for the above batch was (b)(4) ppm (acceptance is (b)(4) or less). The firm's Phase I investigation assigned insufficient (b)(4) time being the root cause. However, the firm's conclusion was based on a previous OOS investigation occurred in 10/12/2022. The firm has no scientific evidence to show insufficient (b)(4) was the cause for the current OOS result. A new sample was tested and the batch was released to the U.S. market in 10/18/2023. Batch (b)(4) was manufactured in 08/31/2023 with an expiration date of (b)(4). C. Your Quality Control (QC) team failed to thoroughly document laboratory investigations such as, but not limited to Column Failure and Device Malfunction. Additionally, there is no documentation available to demonstrate that your Quality Assurance (QA) team reviewed and evaluated the laboratory investigations at the form utilized to document the investigation, at the batch release review and release stage, and the annual product quality review.

    2. Observation 4

      Inadequate aseptic process validation smoke studies

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, During the inspection, we watched videos of airflow visualization studies (smoke studies) performed for the Ampoule Line (b)(4) dated 08/03/2025 and for the Vial Filling Line dated 05/08/2025. The above filling lines manufacture injectable products for the U.S. market. The lack of adequate smoke coverage, turbulent airflow, or poor aseptic practice were observed. Examples including but were not limited to: A. The static smoke studies were not performed under true static conditions. Specifically, you captured and evaluated the airflow between filling machine movement and called it static conditions. You failed to provide a comprehensive baseline study of your cleanroom design and cleanroom airflow before personnel and operations were introduced. [Interventions performed:] a) Video TEC-25051-FIL-1001-A01/B01 (Setting of filling machine) showed turbulent airflow inside the Grade B zone within the (b)(4) RABS enclosure. You failed to demonstrate that there was no ingress of the Grade B air into the Grade A filling line. b) Video TEC-25051-FIL-1001-A02/B02 (Breakage of ampoule during filling) showed an operator's head and upper body extended inside of the Grade A area while performing intervention. This video also [showed updraft in] (b)(4) area in the Grade B room. You failed to demonstrate that the updraft airflow did not result in the ingress of the Grade B air into the Grade A filling line. c) Video TEC-25051-FIL-1001-A04/B04 (Resetting change part) showed an operator's head and upper body inside the Grade A area while performing this intervention. d) Video TEC-25051-FIL-1001-A07/B07 (Resetting of (b)(4)) showed an operator's head and upper body inside the Grade A area while performing intervention "Remove rack for material" and intervention "Re-setting of (b)(4)". C. Per Vial Filling Line intervention performed: a) Video TEC-25051-FIL-1002-A02/B02 (Replacement of (b)(4)) showed the operator brought a (b)(4) replacement from the Grade B room to inside of the Grade A filling area. The replacement (b)(4) was neither contained in a bag nor sanitized before moving into the Grade A filling line. b) Video TEC-25051-FIL-1002-A03/B03 (Resetting on (b)(4) stopper) showed an operator's head, arm, and shoulder inside the Grade A area while performing intervention. c) Video TEC-25051-FIL-1002-A04/B04 (Insertion of (b)(4) stoppers) showed addition of (b)(4) stoppers. In this video, we observed the operator placed the bag containing sterile stoppers directly over the stopper bowl blocking the clean first air. We also observed the outside surface of the bag touching the sterile stoppers inside the bowl. The firm confirmed the stoppers are single bagged. There was no video showing how the bags were transferred to the LAF (b)(4). d) Video TEC-25051-FIL-1002-A05/B05 (Operator is moved under the conveyor belt) showed an operator crawling underneath the conveyor line inside the Grade A filling area. The firm stated this activity was conducted during machine setup. This operator was to transfer a (b)(4) to the other side of the filling line where a (b)(4) unit was located. This video did not show the operator carrying a (b)(4). Thus, the airflow cannot be adequately reviewed. e) Video TEC-25051-FIL-1002-A06/B06 (Re-setting (b)(4)) showed an updraft of airflow to the left side of the conveyor line carrying stoppered vials in the Grade A area. There was no evaluation of the non-laminar airflow. This video also showed a wrench was brought inside the Grade A area without being sanitized. f) Video TEC-25051-FIL-1002-A07/B07 (Fallen vials on (b)(4)) showed operator's hand and arm directly over sterile open vials on the (b)(4). Impacted vials were not rejected. g) Video TEC-25051-FIL-1002-A08/B08 (Fallen vials on conveyor) showed operator's hand and arm directly over sterile o

      Shortened here; the PDF has the full text.

    3. Observation 5

      Inadequate audit trail review procedures

      Batch production and control records do not include complete information relating to the production and control of each batch. Electronic records are used, but they do not meet audit trail requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records. Specifically, Your Audit Trail Review procedure and practice is inadequate. The checklist currently utilized for (b)(4) audit trail reviews do not specifically require the identification and tracking of events logged within the audit trail such as, but not limited to abortion of injections. The audit trail log printout attached to each final product release record is incomplete where only the beginning of the laboratory testing is printed. There are no audit trail log printouts dedicated to stability testing. Additionally, the written procedure for audit trail reviews prior to July 2023 only require random equipment and time length of audit trail logs reviewed. There are a number of batches intended for the U.S. Market and within expiry where the audit trail review was not conducted to verify the reported laboratory data aligns with the audit log record.

    4. Observation 6

      Deficient cleaning disinfection of gloves

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, Your firm lacked adequate justification for washing and sterilizing (b)(4) gloves only To (b)(4) is used. Also, (b)(4) is used as needed and (b)(4) (a sporicide) is used (b)(4). However, there is no written procedure on how to clean (b)(4) gloves. You also have no study to monitor cleaning effectiveness. At the end of each batch production, only the (b)(4) glove is sampled per viable EM procedure. No fingers are monitored. You lacked justification for not monitoring gloves that are used during production and not sampling glove fingers.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Design control - no procedures

      Procedures for design control have not been established.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been adequately established.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 1, 2026.

  • Inspection ending Nov 21, 2025OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Feb 26, 2026FDA-FOIA-2026-2002Inspection recordsRecords released
  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 on Jul 22, 2026. FDAgent holds no copy that FDA posted.

    1. Jul 1, 2026FDA-FOIA-2026-6245Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 6 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3007163376, one row per refused product line.

58 refusals from 2018-07-10 to 2026-06-24 · charged DRUG GMPS on 53, NO ENGLISH on 3 · no FDA sample analysis

FDA firm profile
  • 2026-06-24

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-7232546-4/480002/1

  • 2026-06-24

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-7232546-4/220002/1

  • 2026-04-29

    SODIUM CHLORIDE (REPLENISHER)65RCY19

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1774224-5/540002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172898-9/7140002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172898-9/3230002/1

Show 53 more
  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172898-9/2790002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172886-4/780002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172886-4/5930002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172886-4/2960002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172886-4/280002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172855-9/880002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172855-9/2970002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172819-5/6120002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172819-5/5590002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172819-5/5160002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172819-5/3490002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172819-5/3290002/1

  • 2026-04-28

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172819-5/2980002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-7230541-7/160002/1

  • 2026-04-27

    BUPIVACAINE HYDROCHLORIDE (ANESTHETIC)60QCK79

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-7230541-7/10002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-7230513-6/740002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1773531-4/1330002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172926-8/500002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172926-8/3860002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172926-8/3280002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172926-8/3060002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172868-2/670002/1

  • 2026-04-27

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southwest Imports800-1172654-6/930002/1

  • 2026-04-22

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1774238-5/640002/1

  • 2026-04-22

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1773525-6/210002/1

  • 2026-04-22

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1773516-5/450002/1

  • 2026-04-22

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports92J-3546020-9/900002/1

  • 2026-04-22

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports92J-3546020-9/560002/1

  • 2026-04-22

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports92J-3546020-9/250002/1

  • 2026-04-22

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172955-7/2690002/1

  • 2026-04-22

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172955-7/2320002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1774310-2/3790002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1774301-1/3800002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1774278-1/460002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest ImportsWC1-1772378-1/800002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172893-0/900002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172893-0/8740002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172893-0/560002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172878-1/4750002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172878-1/4250002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172878-1/3750002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172878-1/3250002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172878-1/2750002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172869-0/1270002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172816-1/4310002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172816-1/2720002/1

  • 2026-04-17

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172816-1/2440002/1

  • 2026-04-15

    LIDOCAINE HCL (ANESTHETIC)60QCK40

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports800-1172831-0/2420002/1

  • 2024-03-21

    EPINEPHRINE (ADRENERGIC)60CCK04

    NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-9681206-1/11/3A

  • 2024-03-21

    SODIUM CHLORIDE (REPLENISHER)65RCK19

    NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING

    Division of Southeast Imports799-9681206-1/11/2A

  • 2022-12-23

    MISCELLANEOUS PATENT MEDICINES, ETC.66VDK99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-2502572-5/21/1

  • 2019-06-21

    IMPLANT, DERMAL, COLLAGEN FOR AESTHETIC USE79LMH

    NO PMA 501(f)(1)(B), 801(a)(3); ADULTERATION

    Division of West Coast Imports799-1130869-8/31/2

  • 2018-07-10

    MISCELLANEOUS PATENT MEDICINES, ETC.66VIP99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING

    RX LEGEND 502(a) & (f)(1), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAEK-4632568-1/61/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 89-04Red ListDetention Without Physical Examination of Devices from Firms that Have not met Device Quality System RequirementsImport alert pageAlert on fda.gov

    Date published 2026-07-02

    FDA’s entry
    Huons Co., Ltd. · 100 Bio-Valley-Ro, Jecheon, Chungcheongbuk KOREA (THE REPUBLIC OF)
    FDA’s inspection record for FEI 3007163376
    Huons Co., Ltd. · 100 Bio-Valley-Ro, Jecheon, Korea (the Republic of)

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    1 product

    • 80 N - - GTDevice, Flush, Vascular Access
  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2026-04-03

    FDA’s entry
    Huons Co., Ltd. · 100 Bio-Valley-Ro, Jecheon, Chungcheongbuk KOREA (THE REPUBLIC OF)
    FDA’s inspection record for FEI 3007163376
    Huons Co., Ltd. · 100 Bio-Valley-Ro, Jecheon, Korea (the Republic of)

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    16 products

    • 54 - - I --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Vegan Capsules
    • 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
    • 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
    Show 13 more products
    • 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
    • 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
    • 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2027
Registrant
Huons Co., Ltd.D-U-N-S 631099384

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3007163376 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3007163376. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.