The plant itself: building design and repair, air handling, pressure differentials, temperature and humidity. FDAgent finds 160 such observations in 121 Form 483s issued to 117 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
160
Each quoted below
Form 483s
121
Posted by FDA
Facilities
117
Distinct FEIs
Most recent
Sep 10, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 49 in 2026

Facilities and HVAC observations in Form 483s by inspection year
YearObservations
20081
20091
20100
20110
20121
20131
20148
20157
20164
20176
20189
20199
20202
20218
202215
20238
202418
202513
202649

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.4221 CFR 211.4421 CFR 211.4621 CFR 211.4821 CFR 211.5021 CFR 211.5221 CFR 211.58

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“HVAC” · “air handl*” · “AHU*” · “pressure differential*” · “differential pressure*” · “temperature and humidity” · “humidity control*” · “humidity monitor*” · “air change*” · “air filtration” · “state of repair” · “ceiling tile*” · “peeling” · “flaking” · “water leak*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 160 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 1

    … e) Your firm is not following SOP 206.113 Brisbane Stability Oven Operation, Rev 0 issued 08AUG2022 regarding (b) (4) downloading and review of the temperature and humidity readings from the data loggers for the stability chambers. The data loggers reached their maximum storage capacity on October 6, 2022 and has not recorded temperature or humidity in the stability chambers since that date.

    Contains “temperature and humidity”Read the Form 483 →

  2. Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 9

    Your firm has not fully qualified the stability chambers used for long term (30C/65%RH - Oven ID O-0007) and accelerated stability studies. The chambers were installed in April 2022. The Operational Qualification (OQ) report approved on August 15, 2022 by QA contains no information about the actual operation of the chambers including no temperature and humidity readings, no verification documentation that the digital read out of the temperature …

    Contains “temperature and humidity”Read the Form 483 →

  3. Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 1

    … that "all equipment used in the manufacturing, processing, packaging, or holding of Drug Substance, Drug Product, or Medical Devices is maintained in a good state of repair" (§6.3.2.2).

    Contains “state of repair”Read the Form 483 →

  4. Sumitomo Osaka Cement Co., LtdInspection ended Oct 27, 2023 · FEI 3003943727 · Observation 4

    … Deviation DV22002 and DV22003 was initiated for excursions in humidity (74%) for (b)(4) and for temperature and humidity (35.8C and 70.4% RH) for (b)(4) in the 25C/60%RH stability chamber. However, no CAPA was initiated. 5. The analytical method for the raw material (b)(4) used in the manufacturing of (b)(4) API is not verified. The firm does not perform testing of assay and instead confirm assay with the COA of supplier to ensure if the results …

    Contains “temperature and humidity”Read the Form 483 →

  5. Linhai Tianyu Pharmaceutical Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3013345425 · Observation 2

    … by 2-inch pan-like item placed under the utility pipes that connect to the (b) (4) station and (b) (4) tanks 2) a ~2 feet by 1 foot reddish/brown area of peeling floor under utility pipes that connect to the (b) (4) station 3) a drooping clear coil with reddish/brown residue that connects to utility pipes that connect to the (b) (4) station (b) (4) 217 with a drooping clear coil with reddish/brown residue that carries (b) (4) to utility pipes …

    Contains “peeling”Read the Form 483 →

  6. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 4

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, a) Not all locations on Workshop (b) (4) filling line, used for filling products (b) (4) Injection and (b) (4) Suspension, shows adequate air flow without turbulence during smoke studies. 1) The (b) (4) area next to the Workshop (b) (4) filling line with Grade A airflow is used for opening the LAF (b) (4) …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  7. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 6

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) Operators performing critical (b) (4) interventions on aseptic filling lines in Workshops (b) (4) and (b) (4) are not monitored after completing the intervention on the Grade A filling line. For example, 1) SOP #PO-3 112 005-012, SOP for Filling Operations of Workshop (b) (4) does not require monitoring of gloved hands after each …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  8. Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Monitoring of nonviable particles on Unit (b) (4) filling line of Workshop (b) (4) is not located within (b) (4) of the vial track where (b) (4) vials move towards the (b) (4) The point where vials turn left towards the (b) (4) is monitored by an online nonviable particle port that is located (b) (4) from the vial track. b. …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  9. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 8

    … identification of environment isolate aids in the evaluation of cleaning/ sanitization effectiveness, personnel training, deterioration and malfunction of AHU system and facilities." The EM and personnel monitoring samples for the Grade B area is described in the Frequency of Microbial Isolate Exhibit-II i.e., for routine plates observation to (b) (4) (b) (4) (b) (4) The Assistant Manager QC Microbiology explained the EM samples are visually …

    Contains “AHU*”Read the Form 483 →

  10. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 16

    As confirmed by the Assistant General Manager Project & Engineering Department, there are no Architectural Layouts (As Build) engineering diagrams for the HVAC units in (b) (4) manufacturing facilities. In addition, a. There is not Architectural Layouts for the (b) (4) Restricted Access Barrier System ((b) (4) RABS) that is used to aseptically manufacture (b) (4) finished drug products in the (b) (4) aseptic fill line in (b) (4) (b) (4) or for …

    Contains “HVAC”Read the Form 483 →

  11. Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. OPGInspection ended Dec 16, 2022 · FEI 3002809097 · Observation 1

    … The plant (b)(4) period that occurs for (b)(4) Environmental and HEPA air filtration systems, monitoring is not conducted during the plant (b)(4) period. (b)(4) (b)(4) for controlled spaces are not maintained. Cleaning and plant (b)(4) occurs after this (b)(4) plant (b)(4) Cleaning validations are not assured as accurate and continuously valid as environmental (b)(4) are not collected and tested for during the plant (b)(4) period. B. The firm's …

    Contains “air filtration”Read the Form 483 →

  12. Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 5

    … There are (b) (4) individual HVAC Units that are used to provide HEPA filtered high quality air for the Formulation Manufacturing operations [i.e. (b) (4) form]. The Senior Manager of Engineering confirmed that there are no As Built diagrams/drawings for the (b) (4) HVAC units. b. There are no As Built diagrams/drawings for the (b) (4) system that is used for the manufacture of (b) (4) forms. c. There is an Isometric diagram (drawing number …

    Contains “HVAC”Read the Form 483 →

  13. Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 12

    … Cleaning of (b) (4) and Handling of Material Collected from (b) (4) document number SOP MDP MAM 019216, dated 06 Oct 2022, establishes to "check the differential pressure across the (b) (4) filter (It should less than (b) (4) mmwc)" and "If the differential pressure across the (b) (4) filter is found (b) (4) mmwc then rectify it before use". The standard procedure's "(b) (4) mmwc" is inconsistent with the OEM's specification of between (b) …

    Contains “differential pressure*”Read the Form 483 →

  14. Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 14

    … There are (b) (4) individual HVAC Units that are used to provide HEPA filtered high quality air for the Grade D (ISO 8) API (b) (4) manufacturing areas. The Senior Executive of Engineering confirmed that there are no updated As Built engineering diagrams/drawings for the (b) (4) HVAC units. b. There are numerous pipes for the various manufacturing utilities and piping connections for the (b) (4) and vessels that are used for the manufacture of …

    Contains “HVAC”Read the Form 483 →

  15. QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 1

    … Your firm did not evaluate the room environmental conditions, such as temperature and humidity, as part of the investigation. Additionally, no second person verification of (b) (4) colony counts is conducted and no other information, such as the morphology and/or Gram stain, about the second isolated CFU is available; your firm deemed the lot of Oxytocin eligible for release and distributed this product over the period of 03/25/2022 - 03/29/2022. …

    Contains “temperature and humidity”Read the Form 483 →

  16. QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 2

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, Your firm's environmental and personnel monitoring program does not include sampling of all potential routes of microbial contamination. For example: A) On 08/16/2022, during our observation of sterile filling of Epinephrine, Preservative Free (PF), 10mcg/ml in 10ml Dextrose 5% in (b) (4) (D5W) Syringe, Lot# (b) (4), Expiration Date: …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  17. Meiji Seika Pharma Co., Ltd.Inspection ended Sep 2, 2022 · FEI 3008927877 · Observation 3

    Failure to properly maintain buildings and facilities used in the manufacture and storage of intermediates and API. Specifically, Raw Material warehouse No. 1 used to store raw materials and intermediates for the use in production of (b) (4) has water leak damage and mold growth on ceiling tile over (b) (4) lot number (b) (4)

    Contains “water leak*”Read the Form 483 →

  18. Carolina InfusionInspection ended Aug 12, 2022 · FEI 3015826782 · Observation 4

    Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, your sterile compounding cleanroom did not meet the differential specification of (b)(4) in. W.G. or greater during verification testing per [illegible]. It is adjacent to a hallway which is neutral pressure and has no evidence of ISO certification. The compound room was measured as requiring a [illegible] reading using …

    Contains “pressure differential*”Read the Form 483 →

  19. AnazaoHealth CorporationInspection ended Jul 29, 2022 · FEI 3011152407 · Observation 5

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, your firm stores equipment with difficult to clean surfaces inside the ISO 7 areas surrounding the ISO 5 aseptic processing areas, such as surfaces that are porous, particle-generating, or visibly dirty. Examples include the following: A) a clear plastic storage bin in the ISO 7 area of …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  20. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 6

    Unsealed, loose ceiling tiles were observed in your cleanroom. Specifically, I observed an exposed/unsealed fire sprinkler head within your firm's ISO 8 Ante Room/Gowning, and ISO 7 HD Anteroom/Prep Room, and ISO 7 Buffer Room/Cleanroom along with unsealed ceiling tiles.

    Contains “ceiling tile*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about facilities and HVAC in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.