AnazaoHealth Corporation Form 483, July 2022
FDA issued this Form 483 to AnazaoHealth Corporation in Las Vegas, Nevada (FEI 3011152407) at the end of a drug inspection that ended July 29, 2022. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 21, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 29, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Nov 21, 2022
- 115 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Quality unit not reviewing sterility data packets
The quality unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred. Specifically, the firm has not been reviewing sterility test data packets from their contract testing laboratory for all drug products produced as part of their batch release process for the (b) (4) Suite since January 20, 2015 and for the (b) (4) Suite built in August 2020. Examples of drug products produced in these areas include, but are not limited to (b) (4) Nutrient Cocktail Injection 50mL in Clean Rooms (CRs) (b) (4) Thiamine HCl/Pyridoxine HCl 20/100mg/mL Injection 30mL in CRs (b) (4) and Testosterone Cypionate 200mg/mL Injection 5mL, 10mL and 30mL in CR (b) (4)
- 2
Inadequate validation of implantable hormone pellets
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, during the validations of your Testosterone 200 mg and Estradiol 6 mg implantable pellets, your firm's sampling plan did not include a sufficient number of samples during potency testing to provide statistical confidence of quality within a batch and between batches. Further, your firm has not demonstrated in these validations that your products safely deliver a constant rate of these hormones over an extended period of time, instead of having immediate release characteristics. Between November 18, 2019 and March 31, 2022, your firm received approximately 26 reports of adverse events related to your Testosterone and Estradiol implantable pellets, including reports of death, heart attack, stroke, embolism, and breast cancer.
- 3
Failure to thoroughly investigate complaints and sterility failure
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) your firm received approximately 26 reports of adverse events related to your Testosterone and Estradiol implantable pellets, including reports of death, heart attack, stroke, and breast cancer. However, your firm's investigations into these complaints did not include consideration of additional testing to determine whether these finished drug products have the strength and quality that they purport or are represented to possess. Additionally, 24 out of 26 of these complaint investigations did not include the findings of the investigations, specifically your firm's determination about whether your drug products may have caused or contributed to these adverse events. B) sterility failure identified by Event 2022-0788 during production of (b) (4) Nutrient Cocktail, Batch (b) (4), 50 mL vials, using (b) (4) as per (b) (4) (b) (4) Received Date 5/13/2022 has not been completed in a timely manner and is under investigation. This investigation must assess the hazards of the aseptic filling operation and determine whether other batches produced on the same production line were affected.
- 4
Unvalidated rapid sterility test method unsuitable
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented. Specifically, on May 19, 2022, your contract testing laboratory detected visual turbidity in the sterility testing (b) (4) for your (b) (4) Nutrient Cocktail lot (b) (4), and confirmed that this turbidity was caused by microbial contamination with Staphylococcus epidermidis. However, your contract testing laboratory failed to detect this microbial contamination in lot (b) (4) using the (b) (4) method, which indicates that this rapid microbiological test method may be unsuitable for performing sterility testing on your drug products. The (b) (4) test method was also used to perform sterility testing on approximately (b) (4) lots of the following drug products between July 1, 2021 and July 1, 2022: 1. (b) (4) 2. Ascorbic Acid (PF/Non-Corn) 500mg/mL 3. Ascorbic Acid (PRESERVED/Non-Corn) 500 mg/mL 4. B-COMPLEX 5. B-NICOTINAMIDE ADENINE DINUCLEOTIDE 125 mg/mL 6. COMPOUNDED (b) (4) 50 MG/ML 7. COMPOUNDED (b) (4) 50 MG/ML 8. EDETATE DISODIUM (PF) 150mg/mL 9. GLUTATHIONE (PF) 200 MG/ML 10. GLUTATHIONE (PRESERVED) 200 mg/mL 11. L-CARNITINE 500 MG/ML 12. LIPOIC ACID 25 mg/mL 13. LYSINE HCL 100 mg/mL 14. METHIONINE/INOSITOL/CHOLINE 25/50/50 MG/ML 15. METHYLCOBALAMIN 10,000 MCG/ML 16. METHYLCOBALAMIN 5,000 MCG/ML 17. MIC W/CYANOCOBALAMIN 25/50/50/1 MG/ML 18. (b) (4) Nutrient Cocktail 19. THIAMINE HCL 20 MG/PYRIDOXINE HCL 100 MG/ML
- 5
Deficient cleaning system for aseptic processing areas
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, your firm stores equipment with difficult to clean surfaces inside the ISO 7 areas surrounding the ISO 5 aseptic processing areas, such as surfaces that are porous, particle-generating, or visibly dirty. Examples include the following: A) a clear plastic storage bin in the ISO 7 area of Clean Room (b) (4) with a (b) (4) sticker on the outside; larger plastic storage bins with (b) (4) (b) (4); and a (b) (4) trash can. B) a stepstool that is stored under Biological Safety Cabinet (BSC) (b) (4) in ISO 7 area of Clean Room (b) (4) with various stickers and a chair used by (b) (4) with sticker on the back. I also observed stains on the (b) (4) used during mixing in BSC (b) (4) C) cracked front shields (sashes) on (b) (4) Hoods ((b) (4)) (b) (4) in ISO 7 area of CR used to (b) (4) for further (b) (4). The firm does not know when these cracks occurred and any negative effects on its products.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3011152407, newest first.
- Form 483, August 2025Inspection ended Aug 8, 2025 · Posted Sep 2, 2025OAI
- Form 483, September 2024Inspection ended Sep 23, 2024 · Posted Feb 7, 2025OAI
- Form 483, September 2019Inspection ended Sep 19, 2019 · Posted Nov 27, 2019OAI
- Form 483, May 2017FDA record date May 15, 2017 · Posted Jan 17, 2024
- Form 483, April 2017FDA record date Apr 28, 2017 · Posted Jan 17, 2024
- Form 483, July 2015FDA record date Jul 23, 2015 · Posted Jan 17, 2024
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.