Skip to content

AnazaoHealth Corporation

7465 W Sunset Rd Ste 1200, Las Vegas, Nevada, United States

FEI 3011152407

FDA has 5 inspections on file for AnazaoHealth Corporation in Las Vegas, Nevada (FEI 3011152407), from 2015 to 2025. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

FDA has issued 2 warning letters under this FEI, the latest on (CDER · Division of Pharmaceutical Quality Operations IV). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
5, 2015–2025
5 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
4 of 5
3 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
7 posted
Requested under FOIA
2 requests, latest Jul 25, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    3. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    4. Complaint Investigation/Follow-Up Findings

      Complaint records are deficient in that they do not include the findings of the investigation and follow-up.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate investigation documentation

      Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, A. On April 12, 2024, your control testing laboratory analyzed the potency of riboflavin in your human sterile drug product PlenishIV Nutrient Cocktail lot (B)(4) and found that the chromatogram of the sample "showed different peaks" than the standard chromatogram, resulting in superpotent results of 130.2%. The control testing laboratory did not investigate this out of specification event, but instead obtained a new "standard" from your firm and reperformed analysis with this new "standard" to obtain results within specifications. Your firm relied on these new results to approve the release and distribution of this drug product lot. B. On April 18, 2024, your control testing laboratory obtained subpotent Pyridoxine HCl results for three lots of your human sterile drug product PlenishIV Nutrient Cocktail (lots (B)(4), (B)(4), and (B)(4)). The control testing laboratory appeared to perform a preliminary investigation and reported their conclusion to your firm on April 22, 2024, that the OOS root cause was an analyst preparing the samples incorrectly but did not provide a scientific rationale to support this conclusion. On April 30, 2024, the control testing laboratory obtained results within specifications from newly prepared samples, and confirmed the OOS results from the original samples. Your firm relied on the new results to invalidate the original results and approve the release and distribution of these three human drug product lots.

    2. Observation 2

      Broken vial inserts / glass contamination

      Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product. Specifically, Your firm has not ensured that the glass insert in the container closure system of your implantable pellets remains integral throughout shipment and storage of these sterile human drug products. Between October 31, 2022 and June 19, 2024, your firm received 8 complaints related to glass fragments found inside the pellet container closure system from the broken vial inserts. Glass fragments introduce potential risks to patients if the glass contamination is undetected.

    Show observation 3
    1. Observation 3

      Missing adverse-event reporting info on labels

      The containers of your outsourcing facility’s drug products do not include information required by section 503B(a)(10)(B). Specifically, your containers do not include the following information to facilitate adverse event reporting: www.fda.gov/medwatch and 1-800-FDA-1088. Examples of your container labels that do not contain this information: + Testosterone 75 mg/Anastrazole 4 mg pellet • Testosterone 87.5 mg pellet • Testosterone 50 mg pellet

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Quality unit not reviewing sterility data packets

      The quality unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred. Specifically, the firm has not been reviewing sterility test data packets from their contract testing laboratory for all drug products produced as part of their batch release process for the (b) (4) Suite since January 20, 2015 and for the (b) (4) Suite built in August 2020. Examples of drug products produced in these areas include, but are not limited to (b) (4) Nutrient Cocktail Injection 50mL in Clean Rooms (CRs) (b) (4) Thiamine HCl/Pyridoxine HCl 20/100mg/mL Injection 30mL in CRs (b) (4) and Testosterone Cypionate 200mg/mL Injection 5mL, 10mL and 30mL in CR (b) (4)

    2. Observation 2

      Inadequate validation of implantable hormone pellets

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, during the validations of your Testosterone 200 mg and Estradiol 6 mg implantable pellets, your firm's sampling plan did not include a sufficient number of samples during potency testing to provide statistical confidence of quality within a batch and between batches. Further, your firm has not demonstrated in these validations that your products safely deliver a constant rate of these hormones over an extended period of time, instead of having immediate release characteristics. Between November 18, 2019 and March 31, 2022, your firm received approximately 26 reports of adverse events related to your Testosterone and Estradiol implantable pellets, including reports of death, heart attack, stroke, embolism, and breast cancer.

    Show observations 3 to 5
    1. Observation 3

      Failure to thoroughly investigate complaints and sterility failure

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) your firm received approximately 26 reports of adverse events related to your Testosterone and Estradiol implantable pellets, including reports of death, heart attack, stroke, and breast cancer. However, your firm's investigations into these complaints did not include consideration of additional testing to determine whether these finished drug products have the strength and quality that they purport or are represented to possess. Additionally, 24 out of 26 of these complaint investigations did not include the findings of the investigations, specifically your firm's determination about whether your drug products may have caused or contributed to these adverse events. B) sterility failure identified by Event 2022-0788 during production of (b) (4) Nutrient Cocktail, Batch (b) (4), 50 mL vials, using (b) (4) as per (b) (4) (b) (4) Received Date 5/13/2022 has not been completed in a timely manner and is under investigation. This investigation must assess the hazards of the aseptic filling operation and determine whether other batches produced on the same production line were affected.

    2. Observation 4

      Unvalidated rapid sterility test method unsuitable

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented. Specifically, on May 19, 2022, your contract testing laboratory detected visual turbidity in the sterility testing (b) (4) for your (b) (4) Nutrient Cocktail lot (b) (4), and confirmed that this turbidity was caused by microbial contamination with Staphylococcus epidermidis. However, your contract testing laboratory failed to detect this microbial contamination in lot (b) (4) using the (b) (4) method, which indicates that this rapid microbiological test method may be unsuitable for performing sterility testing on your drug products. The (b) (4) test method was also used to perform sterility testing on approximately (b) (4) lots of the following drug products between July 1, 2021 and July 1, 2022: 1. (b) (4) 2. Ascorbic Acid (PF/Non-Corn) 500mg/mL 3. Ascorbic Acid (PRESERVED/Non-Corn) 500 mg/mL 4. B-COMPLEX 5. B-NICOTINAMIDE ADENINE DINUCLEOTIDE 125 mg/mL 6. COMPOUNDED (b) (4) 50 MG/ML 7. COMPOUNDED (b) (4) 50 MG/ML 8. EDETATE DISODIUM (PF) 150mg/mL 9. GLUTATHIONE (PF) 200 MG/ML 10. GLUTATHIONE (PRESERVED) 200 mg/mL 11. L-CARNITINE 500 MG/ML 12. LIPOIC ACID 25 mg/mL 13. LYSINE HCL 100 mg/mL 14. METHIONINE/INOSITOL/CHOLINE 25/50/50 MG/ML 15. METHYLCOBALAMIN 10,000 MCG/ML 16. METHYLCOBALAMIN 5,000 MCG/ML 17. MIC W/CYANOCOBALAMIN 25/50/50/1 MG/ML 18. (b) (4) Nutrient Cocktail 19. THIAMINE HCL 20 MG/PYRIDOXINE HCL 100 MG/ML

    3. Observation 5

      Deficient cleaning system for aseptic processing areas

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, your firm stores equipment with difficult to clean surfaces inside the ISO 7 areas surrounding the ISO 5 aseptic processing areas, such as surfaces that are porous, particle-generating, or visibly dirty. Examples include the following: A) a clear plastic storage bin in the ISO 7 area of Clean Room (b) (4) with a (b) (4) sticker on the outside; larger plastic storage bins with (b) (4) (b) (4); and a (b) (4) trash can. B) a stepstool that is stored under Biological Safety Cabinet (BSC) (b) (4) in ISO 7 area of Clean Room (b) (4) with various stickers and a chair used by (b) (4) with sticker on the back. I also observed stains on the (b) (4) used during mixing in BSC (b) (4) C) cracked front shields (sashes) on (b) (4) Hoods ((b) (4)) (b) (4) in ISO 7 area of CR used to (b) (4) for further (b) (4). The firm does not know when these cracks occurred and any negative effects on its products.

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    2. Product flow through building is inadequate

      The flow of components, drug product containers, closures and in-process materials though the building is not designed to prevent contamination.

  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  7. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 25, 2025.

  • Inspection ending Sep 23, 2024OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 25, 2025FDA-FOIA-2025-9094Form 483Withdrawn
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Oct 24, 2024FDA-FOIA-2024-9483Inspection records· 1 of 7 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011152407 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011152407. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.