Skip to content

Qilu Antibiotics Pharmaceutical Co. , Ltd.

No 849, Licheng District, Jinan, China

FEI 3009831352DUNS 527271779

FDA has 5 inspections on file for Qilu Antibiotics Pharmaceutical Co. , Ltd. in Jinan, China (FEI 3009831352), from 2013 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Qilu Antibiotics Pharmaceutical Co., Ltd. (D-U-N-S 527271779).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
5, 2013–2026
0 OAI · 3 VAI · 2 NAI
Inspections with 483 observations shown
1 of 5
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
1 request, latest Jul 21, 2026
Warning letters
None on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Aseptic process simulations not representative

      Procedures designed to prevent microbiological contamination of drug product purporting to be sterile are not followed. Specifically, a. The process simulations do not represent actual production operations for your sterile API in Unit (b) (4) of Workshop (b) (4) APIs filled in Unit (b) (4) (Sterile (b) (4) and Sterile (b) (4) are used to manufacture sterile injectable products distributed to the U.S. market. (b) (4) Sterile (b) (4) batches were manufactured in manufacturing campaign from 13 June 2022 to 25 August 2022 (74 days) without cleaning or sterilization of manufacturing equipment. At the end of the campaign and prior to initiation of Media fill #(b) (4) equipment with sterile product contact surfaces were cleaned by (b) (4) i. The (b) (4) cycle on 26 August 2022 for (b) (4) 33105 was (b) (4) and (b) (4) 3106 was (b) (4) (b) (4) using (b) (4) of (b) (4) for each. ii. The (b) (4) cycle on 28 August 2022 for (b) (4) 33101, (b) (4) 33102, (b) (4) 33103, and (b) (4) 33104 ranged from (b) (4) to (b) (4) using (b) (4) of (b) (4) for each. iii. The (b) (4) cycle on 29 August 2022 for (b) (4) tank and API filling line was (b) (4) using (b) (4) of (b) (4) iv. After (b) (4) an additional (b) (4) was added to equipment and this volume was used to calculate the level of residue and the quantity of (b) (4) b. For Media fill #(b) (4) (b) (4) were reportedly placed in the drains to capture (b) (4) for the above listed equipment and subsequently emersed into (b) (4) nedia for media simulation incubation. There were no instructions and no documentation in the batch records for the ad c. For Media fill #(b) (4) two separate preparations of non-sterile (b) (4) were dissolved in (b) (4) and used for contact with (b) (4) 33105 and (b) (4) 33106 (without (b) (4) After contact with equipment, all of the (b) (4) were (b) (4) (b) (4) and emersed into (b) (4) canisters of (b) (4) media for media simulation incubation. There were no instructions and no documentation in the batch records for the (b) (4) to each canister of (b) (4) to inhibit the antibiotic residues in production equipment. d. For Media fill #(b) (4) two separate preparations of non-sterile (b) (4) were dissolved in (b) (4) and transferred to the (b) (4) The sterile (b) (4) preparations were dissolved using (b) (4) further transferred to the (b) (4) and transferred to the (b) (4) tank as (b) (4) The (b) (4) were filled on the Unit (b) (4) Sterile API filling line into canisters. Two separate preparations of sterilized (b) (4) media, with (b) (4) were (b) (4) filled into canisters, and incubated for media simulation. No (b) (4) was added to the (b) (4) encountering product contact surfaces. e. For Media fill #(b) (4) incubation records for (b) (4) in (b) (4) media are lacking testing details. i. The dates of incubation at (b) (4)C and movement to (b) (4)C were not documented in media fill testing records. ii. The growth promotion records do not have documentation of inoculum verification. f. The process simulations do not represent actual production operations for aseptic filling of finished product in Unit (b) (4) of Workshop (b) (4) Unit (b) (4) was used to fill (b) (4) batches, (b) (4) Injection. i. Two preparation of (b) (4) was prepared for Media Fill #(b) (4) filled on 24 March 2023. The first preparation, (b) (4) was (b) (4) and filled starting from 8:26 am. The second preparation, (b) (4) was (b) (4) and filled starting from 2:03 pm. The firm reported preparing two media batches to prevent microbial build up for the expected (b) (4) filling operation, but this is not a practice performed for routine production. ii. Not all filled vials are incubated. Media Fill #(b) (4) conducted a fill of (b) (4) vial, but only incubated (b) (4) (b) (4) filled vials were not processed through the (b) (4) because the firm only planned for filling (b) (4) (b) (4) and the remaining vials were rejected. iii. Not all media prepared are incubated as required by SOP # QUAL1009.B, Guideline of Ase

      Shortened here; the PDF has the full text.

    2. Observation 2

      Smoke studies do not demonstrate unidirectional airflow

      Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination might occur during production. a. Smoke studies performed in Unit (b) (4) of Workshop (b) (4) do not demonstrate airflow without turbulence. The filling line was used to fill (b) (4) batches of (b) (4) product (b) (4) Injection. For example, i. The dynamic smoke study videos showed the (b) (4) of vials, vials traveling on the vial track line, movement of (b) (4) stoppering action, and travel out of the filling line, but the video view is narrow. The videos show closeup views of the vials and do not demonstrate smoke from (b) (4) to the vial filling line is without turbulence. ii. The study does not show the impact on smoke flow during (b) (4) manipulations. 15 (b) (4) manipulations were demonstrated during the smoke study, but the flow of smoke is not near the (b) (4) where the operator is performing an intervention. iii. The smoke study videos showed allowed interventions using (b) (4) but the view is narrow (only a closeup view of vials) and does not demonstrate the flow of smoke is without turbulence from (b) (4) to the vial filling line. iv. Personnel are required to pass through the Grade A filling line to access the backside of the filling line for every filling operation. The intervention requires (b) (4) lifting the vial track line, walking through to the other side, and (b) (4) to access the backside of the filling line. No smoke study was performed demonstrating the impact of (b) (4) lifting the vial track line, or a person walking through the Grade A filling line. b. Smoke studies performed in Unit (b) (4) of Workshop (b) (4) do not demonstrate airflow without turbulence. The filling line was used to fill (b) (4) batches of (b) (4) product (b) (4) Injection. For example, i. The dynamic smoke study videos showed the (b) (4) of vials, vials traveling on the vial track line, movement of (b) (4) stoppering action, and travel out of the filling line, but the video view is narrow. The videos show closeup views of the vials and do not demonstrate smoke from (b) (4) to the vial filling line is without turbulence. ii. The study does not show the impact on smoke flow during (b) (4) manipulations. 10 (b) (4) manipulations were demonstrated during the smoke study, but the flow of smoke is not near the (b) (4) where the operator is performing an intervention. iii. The flow of smoke over (b) (4) vials on the path to the (b) (4) were not covered by smoke study. (b) (4) vials travel a distance of (b) (4) before reaching (b) (4) # (b) (4) 37101; (b) (4) vials travel a distance of (b) (4) before reaching (b) (4) # 37102; and (b) (4) vials travel a distance of (b) (4) before reaching (b) (4) # 37103. iv. The smoke studies for the loading of (b) (4) vials for (b) (4) #(b) (4) 37102 and (b) (4) (b) (4) 37103 is insufficient to demonstrate the impact of airflow during movement of vials into the

    Show observations 3 to 5
    1. Observation 3

      Deficient environmental monitoring system

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Monitoring of nonviable particles on Unit (b) (4) filling line of Workshop (b) (4) is not located within (b) (4) of the vial track where (b) (4) vials move towards the (b) (4) The point where vials turn left towards the (b) (4) is monitored by an online nonviable particle port that is located (b) (4) from the vial track. b. Personnel working in the aseptic filling lines are not required to monitor gloves and gown for each exit as required by SOP QCJ723L, Microbiological Monitoring of Aseptic Processing Environments, which requires for Grade A and Grade B personnel, "before exiting from the aseptic room, the operator will be sampled". Operators in all the FDF filling suites are allowed to exit as needed but are only required to sample upon final exit. c. (b) (4) used in the formulation of sterile FDF product in Unit (b) (4) of Workshop (b) (4) is not monitored at point of use. (b) (4) (b) (4) is collected in a (b) (4) tank and the (b) (4) from this tank is used for compounding (b) (4) product (b) (4) Injection. The point of use is not monitored.

    2. Observation 4

      Laboratory controls lack sound test procedures

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, a. Sterility testing of sterile injectable products distributed to the U.S. market requires determination of microbial growth in (b) (4) canisters. There is no requirement to document a check for the (b) (4) for each read and also at final evaluation for microbial growth. b. Environmental monitoring samples, water samples, and product bioburden samples are incubated on (b) (4) plates which are placed in the incubators stored in plastic bags. The firm has not conducted a study which demonstrates no impact on the growth of environmental isolates and other stressed organisms. c. Growth promotion testing of media fill samples do not have verification of the inoculum of microbial organisms.

    3. Observation 5

      QC training procedures missing for operators

      The responsibilities and procedure applicable to the quality control unit are not in writing. Specifically, Your firm does not have established training procedures to oversee the initial and requalification of aseptic filling operators and visual inspection personnel for workshop (b) (4) units (b) (4) A. Your firm has one SOP titled QUAL116.P "Training for Manufacturing and Quality System Personnel" governing the training program in workshop (b) (4) units (b) (4) This procedure lacks quality oversight in the qualification process for aseptic filling personnel's gowning qualification and media fill participation requirements and qualification of visual inspection personnel. The procedure fails to establish set requirements for each specified training, identify the process for qualification and delegate the responsibilities to each department reviewing and approving personnel qualifications. B. Your Quality Manager recognized that the qualification record for visual inspection personnel is solely the completion of the (b) (4) defect test form number PLA1160.ATCH-02-F03. The reviewer signature is not always the QA personnel and visual inspection personnel can be approved for requalification by production workshop personnel. C. The (b) (4) eye exam record received from the doctor does not provide details on the test evaluation preformed. The test does not discuss if personnel was tested for far-sight or near sight vision. Additionally, there are no procedures discussing the review of this record for the qualification of visual inspection. Quality Manager confirmed that the eye exam information is not reviewed to qualify personnel. D. Review of the media fill batch record (b) (4) dated 06/01/2022 and batch record 01/12/23 showed an aseptic operator not receiving sampling training for either media fill conducted within (b) (4) The simulation protocol and report for unit (b) (4) workshop (b) (4) dated 01/18/2023 indicates that the operator is required to complete the sampling training but does not show as completed over the last two media fills. The operator is still participating in aseptic filling activities as an operator since 01/18/2023. There is no procedure establishing operators as different roles and tasks and needing different media fill requirements.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jul 21, 2026. It asked for a Form 483.

  • Inspection ending Apr 28, 2021

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Jul 30, 2026. FDAgent holds no copy that FDA posted.

    1. Jul 21, 2026FDA-FOIA-2026-6930Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3009831352, one row per refused product line.

1 refusal on 2019-11-21 · charged DIRECTIONS on 1 · no FDA sample analysis

FDA firm profile
  • 2019-11-21

    CEFEPIME HYDROCHLORIDE (CEPHALOSPORINS)56CIY53

    DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING

    Division of Southeast Imports799-4369113-7/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Qilu Antibiotics Pharmaceutical Co., Ltd.D-U-N-S 527271779

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009831352 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009831352. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.