Buildings, facilities and HVAC in FDA Form 483 observations
The plant itself: building design and repair, air handling, pressure differentials, temperature and humidity. FDAgent finds 160 such observations in 121 Form 483s issued to 117 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 160
- Each quoted below
- Form 483s
- 121
- Posted by FDA
- Facilities
- 117
- Distinct FEIs
- Most recent
- Sep 10, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 49 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 1 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 1 |
| 2013 | 1 |
| 2014 | 8 |
| 2015 | 7 |
| 2016 | 4 |
| 2017 | 6 |
| 2018 | 9 |
| 2019 | 9 |
| 2020 | 2 |
| 2021 | 8 |
| 2022 | 15 |
| 2023 | 8 |
| 2024 | 18 |
| 2025 | 13 |
| 2026 | 49 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.4221 CFR 211.4421 CFR 211.4621 CFR 211.4821 CFR 211.5021 CFR 211.5221 CFR 211.58
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“HVAC” · “air handl*” · “AHU*” · “pressure differential*” · “differential pressure*” · “temperature and humidity” · “humidity control*” · “humidity monitor*” · “air change*” · “air filtration” · “state of repair” · “ceiling tile*” · “peeling” · “flaking” · “water leak*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 160 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Serum Institute of India Pvt. Ltd.Inspection ended Apr 19, 2022 · FEI 3020223359 · Observation 10
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) You do not perform identification each time action level is reached for each (b)(4) 100 b) Your [illegible] did not consider manufacturing operations when determining sample locations. c) You do not perform complete investigations when an action level is reached to include root cause and corrective action. d) You do not have a …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Cadila Healthcare LimitedInspection ended Mar 10, 2022 · FEI 3013712903 · Observation 3
OBSERVATION 3 Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, the Compounding Room used in the manufacturing of sterile injectable drugs is not maintained in a good state of repair to prevent contamination. On 3/2/2022, significant deficiencies were observed during the inspection of Compounding Room (ID: ffiH..f>7) associated with filling line. For example: A. A …
Opens with FDA's citation wording for 21 CFR 211.58Read the Form 483 →
Davis City Pharmacy Inc.Inspection ended Feb 18, 2022 · FEI 3016774626 · Observation 2
Unsealed, loose ceiling tiles were observed in your non-sterile "compounding lab". Specifically, On 2/15/2022, exposed blue wires were observed hanging in plain sight from a loose unsealed ceiling tile of the non-sterile "compounding lab" during the preparation of your non-sterile Testosterone Cream 2%, 20mg, Lot #2002152022 with a beyond use date of 03/15/2022.
Contains “ceiling tile*”Read the Form 483 →
Vita Pharmacy, LLC dba Talon Pharmacy of BoerneInspection ended Nov 2, 2021 · FEI 3015826784 · Observation 1
… OCo) (4) ,_J doors are designed with no safeguards in place to detect and notify of changes in differential pressure in the event that the doors are opened simultaneously. C. A crack was observed in the r(b) (4) l wall of the ISO 7 cleanroom thereby allowing the possible ingress of air from the ISO 8 area. D. A power cord from the i(l5f(4) I in the ISO 8 area was connected to an outlet inside the ISO 7 cleanroom through one of the exhaust vent …
Contains “differential pressure*”Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 7
… breakdown conducted on the - 200355914 initiated September 6, 2020, attributed to maintenance being performed potential root cause into the excursion was the pressure differential fluctuations prior to product filling. Your corrective action was to update work instruction impact assessment section. Environmental trending was not conducted to ensure your clean room was not trending out of environmental control. A scientific justification was not …
Contains “pressure differential*”Read the Form 483 →
STAQ Pharma, Inc.Inspection ended Sep 29, 2021 · FEI 3015144909 · Observation 2
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, There is no environmental monitoring, including but not limited to, the following ancillary equipment located inside the ISO 5 Laminar Flow Hood (LFH), which is located in (b)(4) Room: A) Non-viable (b)(4) and viable (b)(4) hoses feeding into the LFH through the (b)(4) B) Power cord from (b)(4) (pump located in ISO 7) (b)(4) Room …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
The Compounding PharmacyInspection ended Sep 29, 2021 · FEI 3009127876 · Observation 2
… The edge of the tape appears to be darker than the tape itself, and there is evidence of water leakage from under the tape potentially providing an ideal environment for microbial growth. b) your environmental monitoring process does not sample the AC units or the surrounding tape, and your procedures do not specifically call out that the units are cleaned. (b) (4) (b) (4) (b) (4) c) cleanroom and contain a mini-split type of air conditioning …
Contains “water leak*”Read the Form 483 →
People's Custom Rx and Clinical Care, LLCInspection ended Aug 5, 2021 · FEI 3003780900 · Observation 2
Pressure differentials between areas with different air classifications were not monitored prior or during sterile drug production. Specifically, there is no verification of the pressure differentials before or during sterile drug production. Pressure differentials are measured with (b) (4) which are not visible from within the cleanroom. The firm has no alarm system that would signal if room pressures were out of specification. Pressure …
Contains “pressure differential*”Read the Form 483 →
Med Shop Total Care Inc.Inspection ended Jul 27, 2021 · FEI 3002835459 · Observation 2
Your facility design allowed the influx of poor-quality air into a higher classified area. Specifically, a) You replaced the condenser and air handler to the sterile suite on the human side on June 25, 2021 and loss of pressure beginning Friday, 6/25/21 in (b)(4) room at 11:38 am until 06/27/21 at 14:00. You performed cleaning with (b)(4) on Monday, 6/28/21 after the installation but did not recertify the human side and continued to produce and …
Contains “air handl*”Read the Form 483 →
Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 2
… The painted floors in the warehouse were observed to be peeling on multiple days during the inspection. Large areas of the painted surface are missing in front of the (b) (4) and (b) (4) sampling rooms. The damaged floors and rough surfaces do not allow for adequate cleaning and sanitization. d. On 4/14/2021, the paint on the walls of the controlled not classified corridors surrounding the manufacturing rooms for Areas (b) (4) and (b) (4) were …
Contains “peeling”Read the Form 483 →
Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 1
… As part of the investigation you verified cleaning records for the filling line, differential pressure of the room throughout the run, environmental monitoring results (air monitoring, personnel monitoring, and surface sampling), and finish product sterility testing. Since the test results reviewed in your investigation were within specification the batch was released on July 07, 2020 with a BUD of April 30, 2021. However, the investigation did …
Contains “differential pressure*”Read the Form 483 →
Millers of Wyckoff, IncInspection ended Oct 9, 2020 · FEI 3004600183 · Observation 2
Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, your records of differential room pressure are inadequate in that you do not record the quantitative value of the pressures. Additionally, your records did not document pressure excursions for your Sterile Hazardous Room in the following instances. Your most recent cleanroom certification report for the Hazardous Room (ISO …
Contains “pressure differential*”Read the Form 483 →
Vital Care of Dickson, LLC.Inspection ended Mar 11, 2020 · FEI 3015826069 · Observation 3
Pressure differentials are not monitored in areas where aseptic processing occurs. Specifically, A) Pressure differentials between areas with different air classifications (ISO 6 cleanroom and ISO 7 anteroom) are not routinely monitored/documented prior or during sterile drug production. A review of the firm's compounding records noted that the firm does not routinely document pressure differentials. B) Pressure differentials are measured with …
Contains “pressure differential*”Read the Form 483 →
Surgery Pharmacy Services, Inc.Inspection ended Dec 6, 2019 · FEI 3010704905 · Observation 7
Pressure differentials between areas with different air classifications were not monitored prior to or during sterile drug production. Specifically, there is no verification of the pressure differentials before or during sterile drug production. Pressure differentials are measured with manometers which are not visible from within the cleanroom. The values are documented but not recorded [illegible].
Contains “pressure differential*”Read the Form 483 →
Rapid Equine Solutions, LLCInspection ended Aug 9, 2019 · FEI 3006708880 · Observation 4
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, a) Aseptic manipulations occur in the (b) (4) hood, model (b) (4) serial (b) (4) that is not ISO5 classified. In addition, the blending of ingredients for Aspirin 40% (Sodium Salicylate 400mg/mL) Batch # 20190724-2 and Folic Acid 50mg/mL Batch #20190724-3 was observed to occur on a …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →
Cipla Ltd. Virgonagar SiteInspection ended Jul 19, 2019 · FEI 3002806691 · Observation 1
… The root cause for the OOS was determined as "the higher temperature and humidity conditions are not favorable to retain the original characteristics of the (6)(4) USP material". Review of the overlays of the chromatographic data for 0 - 36 months stability testing for Lots: (6) 4) and (0) (4) shows that the main (0)(4) peak shifts from around (b)' minutes to around (8) © minutes for both lots during the 0 - 36 month period. However, you do not …
Contains “temperature and humidity”Read the Form 483 →
Cipla Ltd. Virgonagar SiteInspection ended Jul 19, 2019 · FEI 3002806691 · Observation 6
… Furthermore, your firm management informed us during the inspection that the packaging rooms are not controlled or monitored for temperature and humidity. As such, you have no way to identify or confirm if personnel are performing packaging of the intermediate under the specified conditions. Note that (0) (4) intermediate is temperature, moisture, and oxygen sensitive and can easily form degradation/decomposition products upon exposure to these …
Contains “temperature and humidity”Read the Form 483 →
Hieber’s PharmacyInspection ended Jul 17, 2019 · FEI 1000121499 · Observation 1
Procedures designed to identify and prevent insanitary conditions are not established and followed by your firm. Specifically, Your firm did not perform appropriate environmental monitoring in your aseptic processing areas. For example, pressure differentials between areas with different air classifications were not monitored before or during sterile drug production. The air pressure differential between the ISO 5 (b) (4) and the ISO 7 clean room …
Contains “pressure differential*”Read the Form 483 →
""ImprimisRx PharmacyInspection ended Apr 9, 2019 · FEI 3003348498 · Observation 1
The ISO 7 Filling Room is not adequately constructed to ensure aseptic processing conditions. Specifically, during the cleaning of the ISO 7 Filling Room, we observed that the ceiling tiles were moving up and down when the technicians were wiping them with a mop. Within the ISO 7 Filling Room, the ISO 5 Laminar Air Flow Hood is used for the filling of sterile ophthalmic and injectable drug products.
Contains “ceiling tile*”Read the Form 483 →
Metro Drugs 3rd Avenue CorpInspection ended Apr 5, 2019 · FEI 3011795133 · Observation 5
Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, pressure differential readings for (b) (4), which monitors the pressure from the ISO 7 Hazardous Prep Room to the ISO 8 Non-Hazardous Prep/Buffer Room (established negative pressure differential limit (b) (4)), were out of specification on 1/14/19 to 1/15/19, all of December 2018, and 11/1/18 to 11/27/18. Mixing of …
Contains “pressure differential*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.42Design and construction featuresIn this theme's rule60
- 21 CFR 211.58MaintenanceIn this theme's rule8
- 21 CFR 211.22Responsibilities of quality control unit4
- 21 CFR 211.113Control of microbiological contamination4
- 21 CFR 211.192Production record review4
- 21 CFR 211.44LightingIn this theme's rule1
- 21 CFR 211.52Washing and toilet facilitiesIn this theme's rule1
- 21 CFR 211.56Sanitation1
- 21 CFR 211.63Equipment design, size, and location1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1
Ask FDAgent about facilities and HVAC in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.