Vital Care of Dickson, LLC. Form 483, March 2020
FDA issued this Form 483 to Vital Care of Dickson, LLC. in Dickson, Tennessee (FEI 3015826069) at the end of a drug inspection that ended March 11, 2020. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 20, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 11, 2020
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 20, 2020
- 254 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Unverified APIs may carry endotoxin
Compounding with APIs that have not been verified to assure that they do not contribute endotoxin contamination that may be objectionable given the product's intended use. Specifically, the Certificate of Analysis for the APIs that the firm uses do not document if endotoxin tests have been performed and the firm has not performed any endotoxin testing on APIs or finished sterile drug products which are for intrathecal administration.
- 2
Inadequate media fill studies
Failure to conduct media fill studies that closely simulate aseptic processing operations under the worst-case, most-challenging and stressful conditions. Specifically, the firm compounds TPN products which involves several timely aseptic manipulation steps. The current media fills are performed only with a few aseptic manipulation steps.
- 3
Pressure differentials not monitored
Pressure differentials are not monitored in areas where aseptic processing occurs. Specifically, A) Pressure differentials between areas with different air classifications (ISO 6 cleanroom and ISO 7 anteroom) are not routinely monitored/documented prior or during sterile drug production. A review of the firm's compounding records noted that the firm does not routinely document pressure differentials. B) Pressure differentials are measured with wall-mounted manometers which are not visible from within the cleanroom. For example, I observed the firm performing sterile compounding on 03/05/2020 and I observed that the differential pressure gauge readings between the cleanroom and the anteroom were not within acceptable ranges. The cleanroom reading was .015 and the anteroom reading was .025. The firm was processing patient specific sterile drug products which included Morphine Sulfate 7.5 mg/ml and Morphine Sulfate 12 mg/mL both with a BUD of 03/05/2020 and for intrathecal administration.
- 4
Non-sealed gaps around light fixtures
Procedures designed to prevent insanitary conditions are not established or followed. Specifically, on 03/05/2020, I observed non-sealed air gaps around the light fixtures in the firm's anteroom and cleanroom. The firm was processing patient specific sterile drug products which included Morphine Sulfate 7.5 mg/ml and Morphine Sulfate 12 mg/ml both with a BUD of 03/05/2020 and for intrathecal administration.
- 5
Non-sterile disinfectant used
Disinfecting agents used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, the disinfectant C(b)(4) used by the firm is non-sterile.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.