People's Custom Rx and Clinical Care, LLC

785 E Brookhaven Cir, Memphis, Tennessee, United States

FEI 3003780900

FDA has 4 inspections on file for People's Custom Rx and Clinical Care, LLC in Memphis, Tennessee (FEI 3003780900), from 2015 to 2021. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Jul 2, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2015–2021
2 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
4 of 4
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
4 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate media fills for worst-case conditions

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, the firm compounds sterile drug products which involves several aseptic manipulation steps. The firm's sterile drug product batch size can range up to (b) (4) for the sterile drug product Cyclosporine 1%. The current media fills are performed only with (b) (4).

    2. Observation 2

      Pressure differentials not monitored during production

      Pressure differentials between areas with different air classifications were not monitored prior or during sterile drug production. Specifically, there is no verification of the pressure differentials before or during sterile drug production. Pressure differentials are measured with (b) (4) which are not visible from within the cleanroom. The firm has no alarm system that would signal if room pressures were out of specification. Pressure differential values are only recorded (b) (4).

    Show observation 3
    1. Observation 3

      Drug residue on non-sterile area light fixtures

      Non-microbial contamination was observed in your non-sterile drug production area. Specifically, on 07/13/2021, we observed what appeared to be drug product residue on two ceiling light fixtures in the firm's non-sterile compounding area. These light fixtures were directly above the firm's non-sterile benchtop drug product staging areas. The firm was continuously processing non-sterile drug products in this area during this inspection. On 07/16/2021, we observed that this residue was still on the light fixtures.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Glove sanitization lapses

      Personnel did not disinfect gloves to prevent contamination. Specifically, on 7/16/2019, during the aseptic processing of Tri-Mix, lot #07162019@34, an operator was observed placing her gloved hands outside the ISO 5 area and not consistently re-sanitizing prior to placing her gloved hands under the ISO 5 hood. THIS IS A REPEAT OBSERVATION

    2. Observation 2

      Non-sterile wipes used

      The cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, on 7/16/2019, an operator was observed using a non-sterile wipe to apply sterile, (b)(4) to the exterior of the HEPA filter inside the ISO 5 hood in the cleanroom.

    Show observations 3 to 4
    1. Observation 3

      Smoke study not dynamic

      Review of the certification report for the cleanrooms dated 3/28/19 revealed that smoke studies in the ISO 5 hood were not performed under dynamic conditions.

    2. Observation 4

      Inadequate cleaning for potent drugs

      Your firm produced highly potent drugs without providing adequate cleaning of work surfaces to prevent cross contamination. Specifically, All hazardous, non-sterile drug products including Progesterone and Estriol are produced under a common (b)(4) hood. Your firm uses (b)(4) to clean the work surface in the hood between preparations. Your firm has no evidence to show that the use of (b)(4) will effectively remove residues which might be present on the hood surface after production.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Operator introduced exposed skin into ISO 5

      On 6/25/18, during the aseptic processing of Dexamethasone NaPO4 24 mg/mL Injectable, lot #06252018@1, an operator was observed placing her gloved hands outside the ISO 5 area and not re-sanitizing prior to placing her gloved hands under the ISO 5 hood. The same operator was observed wearing a face mask and hairnet which left the skin of her forehead partially exposed. The operator was observed to introduce the exposed skin of her forehead inside the ISO 5 hood.

    2. Observation 2

      No endotoxin testing for intrathecal products

      You have no assurance that the endotoxin level of your intrathecal drug products are safe, since you do not have any endotoxin data and your firm doesn't perform endotoxin testing for the finished product. These preparations are made using non-sterile starting material. Furthermore, there is no endotoxin testing data for your APL. In addition, the stock solution for Baclofen (Baclofen USP Powder and Sodium Chloride) is [illegible] and never tested for sterility or endotoxin after repeated use. The stock solution of Papaverine/Phentolamine is also [illegible] which are initially tested for sterility only and then not re-tested after repeated use. Your firm produced [illegible] lots of intrathecal drug products between 3/25/18-6/26/18 which were not tested for endotoxin prior to being dispensed to patients. For example, Baclofen Intrathecal 1000 mcg/ml Injectable, lot #05072018@71 was produced on 5/7/18 under Rx [illegible] for patient [illegible].

    Show observations 3 to 5
    1. Observation 3

      Broken/zero differential pressure gauges

      On 6/27/18, I observed that the magnahelic gauge monitoring differential pressure between the ISO 8 anteroom and unclassified area was at "0". In addition, the gauge used to monitor the pressure between the ISO 7 cleanroom and ISO 8 anteroom was not working. During this time, an operator was preparing the following two lots of intrathecal drug product under the ISO 5 hood which were dispensed to patients: A. Morphine/Baclofen Intrathecal 35 mg-100 mcg/ml Injectable, lot #06272018@14 (Rx [illegible]); B. Morphine/Bupivacaine Intrathecal 40 mg-20 mg/ml Injectable, lot #06272018@3 [illegible].

    2. Observation 4

      SOP lacks disinfectant contact time

      SOP #3.300.303 entitled "Disinfectant Solution and [illegible]" (Effective date: 9/11/17) does not identify the contact time used for the [illegible] disinfectants. In addition, there is no documentation to substantiate the [illegible] minute contact time currently in use.

    3. Observation 5

      Unverified depyrogenation process/location

      Your firm uses [illegible] for the depyrogenation of glassware used in the production of sterile, injectable drug products. The (b)(4) used for depyrogenation for [illegible] minutes has never been verified. In addition, the [illegible] is located in an area which is not in close proximity to the ISO 5 hood. In this case, the (b)(4) is located in the ISO 8 anteroom which requires that depyrogenated glassware be transferred through a door leading into the ISO 7 cleanroom for subsequent storage.

  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.

    3. Temperature / Humidity Controls

      Aseptic processing areas are deficient regarding temperature controls.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    5. Calibration/Inspection/Checking not done

      Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

    Show 7 more citations
    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    2. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    4. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    5. Product flow through building is inadequate

      The flow of components, drug product containers, closures, in-process materials, and drug products though the building is not designed to prevent contamination.

    6. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    7. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.

Regulations FDA cited here

The 6 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 4 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003780900 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003780900. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.