Skip to content

People’s Custom Rx and Clinical Care, LLC Form 483, July 2019

FDA issued this Form 483 to People’s Custom Rx and Clinical Care, LLC in Memphis, Tennessee (FEI 3003780900) at the end of a drug inspection that ended July 24, 2019. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 1, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 24, 2019
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 1, 2019
69 days after the inspection
Facility
FEI 3003780900
Memphis, Tennessee

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Glove sanitization lapses

    Personnel did not disinfect gloves to prevent contamination. Specifically, on 7/16/2019, during the aseptic processing of Tri-Mix, lot #07162019@34, an operator was observed placing her gloved hands outside the ISO 5 area and not consistently re-sanitizing prior to placing her gloved hands under the ISO 5 hood. THIS IS A REPEAT OBSERVATION

  2. 2

    Non-sterile wipes used

    The cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, on 7/16/2019, an operator was observed using a non-sterile wipe to apply sterile, (b)(4) to the exterior of the HEPA filter inside the ISO 5 hood in the cleanroom.

  3. 3

    Smoke study not dynamic

    Review of the certification report for the cleanrooms dated 3/28/19 revealed that smoke studies in the ISO 5 hood were not performed under dynamic conditions.

  4. 4

    Inadequate cleaning for potent drugs

    Your firm produced highly potent drugs without providing adequate cleaning of work surfaces to prevent cross contamination. Specifically, All hazardous, non-sterile drug products including Progesterone and Estriol are produced under a common (b)(4) hood. Your firm uses (b)(4) to clean the work surface in the hood between preparations. Your firm has no evidence to show that the use of (b)(4) will effectively remove residues which might be present on the hood surface after production.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3003780900, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.