Millers of Wyckoff, Inc Form 483, October 2020
FDA issued this Form 483 to Millers of Wyckoff, Inc in Wyckoff, New Jersey (FEI 3004600183) at the end of a drug inspection that ended October 9, 2020. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Dec 22, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Oct 9, 2020
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Dec 22, 2020
- 74 days after the inspection
The 2 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate cleaning of potent-drug utensils
Hazardous drugs were produced without providing adequate cleaning to prevent cross contamination. Specifically, your firm produces potent drugs including, but not limited to, Progesterone, Testosterone, and other potent Active Pharmaceutical Ingredients (APIs), or a combination of these drug products. Utensils used in the production of these potent drugs, such as spatulas, jars and glass beakers, are not dedicated and not cleaned with a process that utilizes an agent to deactivate residual APIs. Your firm utilizes a store-bought brand liquid dish detergent and potable water for cleaning of utensils in the processing of potent APIs. The following potent drug products were prepared and produced using the non-sterile hazardous production room on 09/17/2020: A) Testosterone Topical 50 mg/gm 15% Cream BUD: 10/22/2020, Date Made: 09/17/20 B) BIEST ( ) ( ) Progesterone 2 mg/100 mg, Rx: Date Made: 09/17/2020 C) BIEST ( ) ( ) Progesterone 2.5 mg/125 mg, BUD: 12/16/2020, Date Made: 09/17/2020
- 2
Inadequate cleanroom pressure differentials
Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, your records of differential room pressure are inadequate in that you do not record the quantitative value of the pressures. Additionally, your records did not document pressure excursions for your Sterile Hazardous Room in the following instances. Your most recent cleanroom certification report for the Hazardous Room (ISO 7) pressure was recorded at (negative) -0.064" w.c. According to your specification, the acceptance range for differential pressure [illegible]. In this instance, the report recorded the differential pressure reading was out of specification. However, you continued to use this room as well as adjacent cleanrooms for production of sterile drug products. In addition, on 09/25/2020, I observed that the Magnahelic equipment used to monitor the differential reading for the Hazardous Room was (negative) -0.11" w.c., which was not within specifications.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3004600183, newest first.
- Form 483, May 2017Inspection ended May 18, 2017 · Posted Jan 17, 2024OAI
- Form 483, July 2015Inspection ended Jul 16, 2015 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.