Skip to content

Millers of Wyckoff, Inc.

678 Wyckoff Ave, Wyckoff, New Jersey, United States

FEI 3004600183

FDA has 3 inspections on file for Millers of Wyckoff, Inc. in Wyckoff, New Jersey (FEI 3004600183), from 2015 to 2020. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

The most recent OAI inspection ended on May 18, 2017. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2015–2020
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
1 request, latest Jul 8, 2022
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate cleaning of potent-drug utensils

      Hazardous drugs were produced without providing adequate cleaning to prevent cross contamination. Specifically, your firm produces potent drugs including, but not limited to, Progesterone, Testosterone, and other potent Active Pharmaceutical Ingredients (APIs), or a combination of these drug products. Utensils used in the production of these potent drugs, such as spatulas, jars and glass beakers, are not dedicated and not cleaned with a process that utilizes an agent to deactivate residual APIs. Your firm utilizes a store-bought brand liquid dish detergent and potable water for cleaning of utensils in the processing of potent APIs. The following potent drug products were prepared and produced using the non-sterile hazardous production room on 09/17/2020: A) Testosterone Topical 50 mg/gm 15% Cream BUD: 10/22/2020, Date Made: 09/17/20 B) BIEST ( ) ( ) Progesterone 2 mg/100 mg, Rx: Date Made: 09/17/2020 C) BIEST ( ) ( ) Progesterone 2.5 mg/125 mg, BUD: 12/16/2020, Date Made: 09/17/2020

    2. Observation 2

      Inadequate cleanroom pressure differentials

      Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, your records of differential room pressure are inadequate in that you do not record the quantitative value of the pressures. Additionally, your records did not document pressure excursions for your Sterile Hazardous Room in the following instances. Your most recent cleanroom certification report for the Hazardous Room (ISO 7) pressure was recorded at (negative) -0.064" w.c. According to your specification, the acceptance range for differential pressure [illegible]. In this instance, the report recorded the differential pressure reading was out of specification. However, you continued to use this room as well as adjacent cleanrooms for production of sterile drug products. In addition, on 09/25/2020, I observed that the Magnahelic equipment used to monitor the differential reading for the Hazardous Room was (negative) -0.11" w.c., which was not within specifications.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No stability data for expiration date

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use. Specifically, the firm has no stability data to support the 90 day beyond use date for Coenzyme Q-10 in Oil 25 mg/ml injectable lot #02062017@21 (coenzyme Q10).

    2. Observation 2

      Drug products not potency tested

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release. Specifically, a. Coenzyme Q-10 in Oil 25 mg/ml injectable lot #02062017@21 (coenzyme Q10), produced on 2/6/2017 and dispensed on an unknown date was not tested for potency. b. Mineral Mix lot #03152017@50 (b) (4) produced on 3/15/2017 and delivered on 3/16/2011 was not tested for potency. c. Custom Compound (b) (4) Modified Capsule lot #03082017@1 (b) (4), produced on 3/8/2017 and delivered on 3/8/2017, was not tested for potency. d. Adrenal Capsule lot #01182017@50 (b) (4), produced on 1/19/2017 and delivered on 1/25/2017, was not tested for potency. e. Acetylcysteine/CoQ10/Lipoic Acid/Vitamin D3 250 mg/75 mg/50 mg/1000U Capsule lot #02082017@79 (coenzyme Q10), produced on 2/13/2017 and dispensed on an unknown date, was not tested for potency.

    Show observations 3 to 6
    1. Observation 3

      Sterility and endotoxin not tested

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements. Specifically, Coenzyme Q-10 in Oil 25 mg/ml injectable lot #03272017@78, produced on 2/6/2017 and Mineral Mix lot #03152017@50, produced on 3/15/2017 were not tested for sterility and endotoxin.

    2. Observation 4

      Components not identity-tested

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist. Specifically, there is no identity testing of the following active ingredients: a. Coenzyme Q10 used for the sterile production of Coenzyme Q-10 in Oil 25 mg/ml injectable lot #02062017@21 on 2/6/2017 and Acetylcysteine/Co-Q10/Lipoic Acid/Vitamin D3 250 mg/75 mg/50 mg/1000U Capsule lot #02082017@79 on 2/13/2017. b. (b) (4) used for the sterile production of Mineral Mix lot #03152017@50 on 3/15/2017. c. (b) (4) used for the production of Custom Compound Modified Capsule lot #03082017@1 on 3/8/2017. d. (b) (4) used for the production of Adrenal Capsule lot #01182017@50 on 1/19/2017.

    3. Observation 6

      Inadequate use of disinfecting agents

      The firm's use of disinfecting agents in the cleanroom and ISO 5 areas is inadequate and infrequent. Specifically, there is no data to support the contact times for the cleaning agents in the ISO 5 (b) (4) and ISO 7 cleanroom. Examples of cleaning agents and contact times are as follows: (b) (4) [illegible]

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

    4. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.

    5. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function.

    Show 7 more citations
    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    4. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    6. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

    7. Product flow through building is inadequate

      The flow of components, drug product containers, in-process materials, and drug products though the building is not designed to prevent contamination.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jul 8, 2022. It asked for a Form 483.

  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Jul 8, 2022FDA-FOIA-2022-4957Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.

Show all 9

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004600183 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004600183. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.