Imprimis NJOF LLC
New Jersey
FEI 3013024146
FDA has 4 inspections on file for Imprimis NJOF LLC in New Jersey (FEI 3013024146), from 2017 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent has not read its observations yet; the PDF has them.
The most recent OAI inspection ended on Apr 3, 2024. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 4, 2017–2026
- 3 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 4
- 1 PDF not read yet · 1 posted 483 not matched to an inspection
- Requested under FOIA
- 2 requests, latest Mar 11, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Released OOS products not rejected
Drug products failing to meet established specifications are not rejected. Specifically, The firm received Out-of-Specification (OOS) results for stability or retain samples for the lots listed in the table below which remained in the market through their Beyond Use Dates. The investigations remained open although Change Controls had been initiated, and closed, to change the BUD for the subject products from 360 Days to 180 or 150 days without scientific rationale. mg/mL), Lidocaine (01AUG2024) Specification: (B)(4) for Retain Sample at day 197 (BUD: 360 Days) (LIR-24-015) (30AUG2024) Specification: (B)(4) for Retain Sample at Day 168 (BUD: 360 Days) Prednisolone (1%) - Moxifloxacin (0.5%), Bromfenac (0.075%) (PMB) (09MAR2024) Bromfenac Potency OOS (Result: 82.5%; Specification: (B)(4) for (B)(4) Temp Stability Sample (BUD: 360 Days) Change Control CC-GEN-OCT2023008 changed BUD from 360 Days to 150 days. Sterile Ophthalmic Solution (LIR-23-5) (09MAR2024) Bromfenac Potency OOS (Result: 86.3%; Specification: (B) for (B) (BUD: 360 Days) (B) Bromfenac Potency OOS (Result: 88.7%; (03JUL2024) Specification: (B)(#) for Retain Sample at Day 185 (BUD: 360 Days)
- Observation 2
Incomplete investigation of inspection failures
There is a failure to thoroughly review any unexplained discrepancy, the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, 1) The firm's visual inspection process governed by SOP# VV-QUAL-00606 “(b)(4) Visual Inspection”, Version 16.0, Effective Date: 1/4/2024 is deficient in that the SOP does not require the initiation of an investigation after a failure of the 100% visual inspection (deviation initiated only if inspection fails). The current acceptance limits for 100% visual inspection are (B)(@)IN critical or major defects, and (B)(@) minor defects. The firm's investigation process is also deficient in that identification of particulates is not required until they are found in the AQL inspection process. Examples of products released that initially failed 100% visual inspection for critical defects, and for which no deviation was initiated include, but are not limited to, the following lots of Dexamethasone (1 mg/mL) - Moxifloxacin (0.5 mg/mL) - Ketorolac (0.4 mg/mL) (DMK) Preservative Free (PF) Ophthalmic Injection and Dexamethasone (1 mg/mL) - Moxifloxacin (5 mg/mL) (DM) Solution Sterile Ophthalmic Injection: Product No. | Results of 100% Inspection | Results of (B)(4) Inspection | Results of (B)(#) Inspection DM E — Critical (58% Fail: [B] units for Particles, [B] units for Fibers) - Minor (0% Pass) | Critical (20% Fail: [B] units for Particles, [B] units for Fibers) - Major (0% Pass) | Critical (Pass) - Minor (0% Pass) DMK - Critical (28% Fail: [B] units for Particles, [B] units for Fibers) - Minor (0% Pass) | Critical (Pass) - Major (0% Pass) | N/A DMK - Critical (20% Fail: [B] units for Particles, [B] units for Fibers, [B] units for Crimp Defects) - Minor (0% Pass) | Critical (Pass) | N/A DMK - Critical (8% Fail: [B] units for Particles, [B] units for Fibers, [B] units for Crimp Defects (Functional)) - Minor (8% Fail: [B] units for Crimp Defects (Cosmetic)) | Critical (2% Fail: [B] units for Particles, [B] units for Fibers, [B] units for Crimp Defects) | Critical (0% Pass) DMK Critical (4% Fail: [B] units for Cracked/Damaged vial, [B] units for Crimp Defect) - Minor (0% Pass) | Critical (10% Pass) - Major (0% Pass) | N/A DM Critical (40% Fail: [B] units for Particles, [B] units for Fibers) - Minor (0% Pass) | Critical (8% Pass) | N/A DM Critical (14% Fail: [B] units for Particles, [B] units for Fibers) - Minor (0% Pass) | Critical (5% Fail: [B] units for Particles, [B] units for Fibers) - Major (0% Pass) | Critical (Pass) Additionally, the firm conducted a Process Verification (PV) study to assess whether the usage of [illegible] of the [B] was effective in reducing the defect rate for particles/fibers in the filling process of DMK, DM and Moxifloxacin (4 mg/0.8 mL) Preservative Free Injection. The PV DMK Lot 1 failed 100% visual inspection for Critical defects (4% Fail ([B] for fibers, [B] for particles)) and inspection for Critical defects (2% Fail ([B] for fibers, [B] for particles)); no deviation was initiated for failing 100% inspection and no investigation was conducted to identify the source of the particles. The (B)(@) inspection (Critical & Pass) ([B] for fibers, [B] particles) and AQL Passed. 2) No confirmatory testing was conducted for particles observed during retain sample inspection of four (4) out of five (5) lots of Triamcinolone-Moxifloxacin HCl (TM) (15/1) mg/mL PF Ophthalmic Injection (Suspension product), associated with ADE# 2022124 (9 cases of increased inflammation after injections). During visual inspection of the retain samples, the visual inspector identified the particles as API residue in the vials in TM Lot #'s (B)(@) and (B)(Y). However, visual inspectors are not trained on identification of API residue during visual inspection qualification. 3) During the deviation investigation QF-000142, no impact and risk analysis was conducted for glass particle found during the (B)(#) AQL visual ins
Shortened here; the PDF has the full text.
Show observations 3 to 5
- Observation 3
Aseptic processing and media fill deficiencies
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established or followed. Specifically, 1) Although all approved reports of the Airflow Visualization Studies (AVS), conducted in September 2023, within the ISO 5 filling machines documented adequate air flow, the following deficiencies were identified: a) During the review of the AVS (Number: VV-QUAL-01987), Approved: 1/10/2024, for the (B)(4) Aseptic Filling line (Equipment #: (B)(4)) we observed: i) The volume and/or location of the smoke was not sufficient to visualize the airflow pattern during the following interventions: (1) Aseptic connection of sterile tubing to the (B)(@) during set up of the equipment. (2) Change filling tubing set and the needle. b) During the review of the AVS (Number: VV-QUAL-01988), Approved: 1/10/2024, for the (B) Aseptic Filling Line (Equipment #: (B)(4)) we observed: i) The AVS was not conducted under dynamic conditions; the filling line remained static and did not simulate the commercial filling operations. ii) The volume and/or location of the smoke was not sufficient to visualize the airflow pattern over tubing set up during equipment set up. iii) Turbulent and/or upward moving air was observed during the following interventions: (1) [B] tubing set up during equipment set up. (2) Change of the (B)(4) tubing set and the (B)(#). c) During the review of the AVS (Number: VV-QUAL-01989), Approved: 1/10/2023, for the (B)(@) Aseptic Filling line (Equipment #: (B)(@)) within the ISO 5 Laminar Flow Hood (LFH) (Equipment # LFH#) we observed: i) The volume and/or location of the smoke was not sufficient to visualize the airflow pattern during the following interventions: (1) Open cap/tip bag and load filling cap bowl. (2) Placement of tip/cap onto bottle. 2) During observation of aseptic filling operations, the following deficiencies in aseptic behaviors were observed: a) On 03/12/2024, during the aseptic filling of Prednisolone-Moxifloxacin-Nepafenac Sterile Ophthalmic Suspensions (1%, 0.5%, 0.1%), Lot# (B)(@), on the (B)(4) filling machine (Equipment #: (B)(#)), within the ISO located in Room (ISO 7), we observed operators open the door of the (B)(#) of the (B)(4) and enter the ISO 5 filling area with their whole body to perform intervention to remove jammed tip. SOP VV-QUAL-00342 “Filling Procedure for Filling Machine”, Version 4.0, Effective Date: 10/04/2023 does not include instructions for rejection or line clearance after performing the routine intervention “Tip Jam in the Tip Rail”. No environmental monitoring is performed in the area where operators enter the ISO 5 filling area to perform interventions such as loading the bottle, tip and cap hoppers. b) On 03/19/2024, during the aseptic filling of Klarity-C 0.1% Sterile Ophthalmic Emulsion, Preservative Free, Lot# (B)(@), on the (B)(#) (Equipment #: (B)(#)) filling machine, within the ISO 5 Laminar Flow Hood (LFH) (Equipment # LFH-8), located in room (ISO 7), we observed operators cross over open dropper bottles, approximately 4 times, while performing interventions of removing jammed/fallen dropper bottles. The droppers were not rejected, as required by section 10.4 of SOP# VV-QUAL-00339 “Filling for (B)(4) Procedure”, Version 7.0, Effective 10/4/2023, which states “If at any time after bottles are introduced into the LFH any intervention is performed where the first air flow is disrupted between the HEPA filters and the opening of the bottles, the bottles must be rejected”. Additionally, the bowl which contains the tips was placed close to the front of the FH and operators were observed reaching inside the bowl for the caps and the bag for the bottles with their gloved hands. c) During the aseptic filling observed on the [B] and [B] filling machines, forceps and/or scissors that are used to perform interventions, during filling operations were observed placed tip down in the forceps storage jar, preventing the tips of th
Shortened here; the PDF has the full text.
- Observation 4
Missing impurity/degradant testing
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, All drug products manufactured at the firm are not tested for impurities/degradants at release or during stability. Examples of drug products that have been released include: 1. Prednisolone Sodium Phosphate (1%) - Moxifloxacin (0.5%) - Bromfenac (0.075%) Sterile Ophthalmic Solution, Lot# (B)(4) 2. Epinephrine (0.25 mg/mL) - Lidocaine (7.5 mg/mL) Solution Sterile Injectable, Lot# (B)(4) 3. Prednisolone acetate (1%) - Moxifloxacin (0.5%) Suspension Sterile Ophthalmic Drop, Lot (B)(4)
- Observation 5
Equipment not properly cleaned/maintained
Equipment and utensils are not cleaned, maintained, sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality, or purity of the drug product. Specifically, On 03/22/2024, the sterile bottle hopper lid of the (B)(4) filling machine (Equipment #: (B)(@)), within the ISO 5 (B)(4) system, appeared to have a visible orange, brown to black residue on the metal hinges that spanned the length of approximately 8 inches in between the wall and plexiglass barrier of the ISO 5 area. The status of the ISO 5 (B)(4) filling machine on 03/22/2024 was “clean”; firm's management was not aware of the residue or how long the residue had been present on the filling machine. Similar residue was observed in the sterile bottle hopper during smoke studies conducted in September 2023. Approximately [illegible] lots of products were filled on the (B)(#) and released for commercial distribution since September 2023; these include, but are not limited to, the following: - Prednisolone-Moxifloxacin-Bromfenac Sterile Ophthalmic Suspension (1%, 0.5%, 0.075%) Lot # (B)(4) (Date of Manufacturing: 02/05/2024, BUD: 09/01/2024). - Prednisolone Acetate 1% - Moxifloxacin 0.5% - Nepafenac 0.1% Sterile Ophthalmic Suspension Lot # (B)(@) (Date of Manufacturing: 02/01/2024, BUD: 07/29/2024). - Klarity Preservative Free Ophthalmic Solution Lot # (B)(#) (Date of Manufacturing: 01/31/2024, BUD: 01/24/2025).
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 12 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to review discrepancies and failures
(REPEAT OBSERVATION) There is a failure to thoroughly review any unexplained discrepancy, the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) During the review of Adverse Event Investigation ADE2020081 and associated batch record for Dexamethasone/Moxifloxacin, 1/5 mg/ml, PF Injectable solution, lot #(b) (4) it was discovered that the product lot was released for commercial distribution despite multiple failures in routine production in-process and AQL quality checks. Out of (b) (4) boxes ((b) (4) vials) manufactured, (b) (4) boxes ((b) (4) vials) were released into commercial distribution. The summary of the repeated production in-process and AQL quality checks are as follows: Batch Record Package Page Numbers 71, 72 Inspected by Production, (b) (4)% Total Rejects 64 Rejects (Theoretical Batch size (b) (4) vials) Defects Found -11 fiber particles -46 bad crimps (non-leaking) -5 missing caps -1 empty vial -1 scratched, marked or scuffed surface Inspection Results (Pass/Fail) Pass. 73 AQL by Quality 8 Rejects (Batch size (b) (4) vials) -2 bad caps (non-leaking) -6 bad crimps (non-leaking) Fail. 74, 75 Production, (b) (4)% 466 Rejects (Batch size (b) (4) vials) -3 glass particles -10 fiber particles -2 other particles -442 bad caps (non-leaking) -2 embedded particles -7 scratched, marked or scuffed surface Fail. 76, 77 Production, (b) (4)% 42 Rejects (Batch size (b) (4) vials) -32 fiber particles -8 other particles -1 missing cap -1 scratched, marked or scuffed surface Pass. 78 AQL by Quality 10 Rejects (Batch size (b) (4) vials) -3 other particles -3 bad crimps (non-leaking) [Note: initial AQL failed with 13 bad crimps. Subsequently count corrected to 3 with Passing AQL] -4 dirty vials Pass. SOP # PDR-GEN-IPG-013, Inspection Technique, in 5.1.21 states that, "(b) (4)". However, your firm initiated a (b) (4)% inspection after failed AQL for bad crimps, which is not classified as a critical defect. After a (b) (4)% inspection by production, critical defect (3 glass particles) were found, but the firm deviation # AUG2020025 was titled for major defect limit 5.41% (exceeding allowed (b) (4) limit). The final AQL by the Quality group was performed and initial AQL failed with 13 bad crimps. Subsequently, the count was corrected to 3 with passing AQL results. None of the currently applicable SOP indicate that multiple AQL inspections are allowed. The firm continued inspection of the product lot until it passed. The firm had a remaining inventory of (b) (4) boxes ((b) (4) vials) at the time of current inspection. B) Your firm's investigations did not include monitoring of personnel performing critical interventions on sterile products during production including, but not limited to, the following examples where personnel monitoring revealed microbial action limit excursions after performing production operations of products intended to be sterile. These batches have been released after concluding that the product sterility was not affected by the microbial excursions. Review of your investigations since 2019 have uncovered multiple instances where the product sterility may have been compromised. For example: (1) Deviation MAY2020012 was opened on May 14, 2020 because operator (b) (6) had a microbial action limit excursion of 1 cfu on her left hand during the sterile filling of Prednisolone Acetate (1%) / Moxifloxacin (0.5%) sterile ophthalmic suspension, lot: (b) (4). The action limit for gloved fingertips inside the ISO 5 area is (b) (4). This product was filled on the firm's (b) (4) filling machine ((b) (4)), where operators must (b) (4) place the empty bottles in the turntable and (b) (4) cap the bottles using (b) (4). As part of the investigation you verified cleaning records for the filling line, differential pressure of the room throughout the run, environmental monitoring results (air monitoring, personnel monitoring, and surfac
Shortened here; the PDF has the full text.
- Observation 2
No procedures for production process controls
(REPEAT OBSERVATION) There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, The process validation for Prednisolone Acetate/Bromfenac (1/0.075) % Sterile Ophthalmic Suspension, product code (b) (4), is deficient. Process Validation lots (b) (4) were manufactured in 2020 according to process validation protocol PPC-VAL-NJR-047. The (b) (4) PV lot (b) (4) failed specification limits according to the COA provided by the external testing lab when results for sample representing (b) (4) the batch for Bromfenac potency failed the test with a value of 110.4% against a specification limit of (b) (4)%. The firm accepted the failing results and counted the batch as an acceptable PV lot. In addition, the firm rejected the (b) (4) PV batch (b) (4) when potency values (for Prednisolone Acetate) were found OOS for samples representing (b) (4) the batch. The resulting OOS investigation concluded that the lower amount of bulk suspension left over for this batch (i.e. (b) (4) ml) contributed to the lower potency results. However, the firm failed to scientifically explain how the (b) (4) PV lot (b) (4) that has a comparatively similar bulk leftover of (b) (4) ml had passing results. The summary of bulk left over in (b) (4) batches are presented below: Lot Number (b) (4) Bulk Left Over (b) (4) Total Number of Units Filled Average Fill weight Comments Counted towards PV; (b) (4) Lot rejected. Not counted towards PV.; (b) (4) Counted towards PV; (b) (4) Counted towards PV. Failed potency on COA from external lab. Furthermore, additional deficiencies were found during review of PV documents include, but are not limited to: Firm failed to initiate a deviation or investigate when the operators allegedly did not stop the filling process during the (b) (4) PV batch after filling (b) (4) units. Batch records used to document bulk hold time (using the same PV protocol) incorrectly referenced Moxifloxacin and Bromfenac Phase and wrong lot number (b) (4) throughout the batch records for Phase A (Bromfenac). This was neither caught nor corrected during quality review of the batch records. PV batches (b) (4) were released for commercial distribution. In addition, approximately more commercial batches were released for commercial distribution after the process validation batches.
Show observations 3 to 12
- Observation 3
No procedures to prevent microbiological contamination
(REPEAT OBSERVATION) Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established: Specifically, A) The media fill performed does not represent the number and complexity of routine and nonroutine interventions that occur during production of commercial sterile injectable products. B) A procedure is not established to determine the number of open vials inside the (b) (4) system to be rejected after a filling equipment downtime or nonroutine intervention. For example: During the production of Prednisolone Acetate (1%)/Bromfenac (0.075%) Sterile Ophthalmic Suspension, Lot: (b) (4), on (b) (4), the filling line was stopped due to mechanical challenges for a total downtime of 57 minutes. Throughout the 57 minute downtime there were various interventions performed by the mechanic and operator inside the ISO 5 (b) (4) system. The firm's procedure does not require the operators to account or document the type and complexity of interventions performed during a filling run. The media fill performed by the firm only includes routine interventions (b) (4) per media fill run. Since the number and types of interventions are not documented during production, there is no assurance that the media fill studies performed accurately represent production conditions. In addition, the firm does not reject open units inside the filling line that could be potentially exposed to microbial contamination during routine interventions, non-routine interventions, or equipment stoppage.
- Observation 4
Adverse event reports not timely submitted
Your outsourcing facility has not submitted an adverse event report to FDA in accordance with the content and format requirements established through guidance or regulation under 21 CFR 310.305 as required by section 503B(b)(5). Specifically, The following Adverse Event Reports were not reported to FDA in 15 calendar days after first receiving information about the adverse event: ADE Number 2017012 Product Triamcinolone (15mg/mL)-Moxifloxacin (1mg/mL) Suspension Injection ADE Received 8/1/2017 ADE Reported to FDA 8/18/2017 (17 days); 2017014 Triamcinolone (15mg/mL)-Moxifloxacin (1mg/mL) Suspension Injection 8/10/2017 9/20/2017 (40 days); 2017015 Triamcinolone (15mg/mL)-Moxifloxacin (1mg/mL)-Vancomycin (10mg/mL) Suspension Injection 8/11/2017 9/18/2017 (37 days); 2017016 Triamcinolone (15mg/mL)-Moxifloxacin (1mg/mL) Suspension Injection 9/4/2017 10/2/2017 (28 days); 2017017 Prednisolone (1%)-Gatifloxacin (0.5%)-Nepafenac (0.1%) Suspension 9/20/2017 10/31/2017 (41 days); 2019003 Moxifloxacin 1mg/mL Solution Injection (b) (4) 8/28/2019 9/24/2019 (26 days); 2019015 Triamcinolone (15mg/mL)-Moxifloxacin (1mg/mL) Suspension Injection 11/8/2019 11/27/2019 (19 days); 2019027 Triamcinolone (15mg/mL)-Moxifloxacin (1mg/mL) Suspension Injection 12/4/2019 12/20/2019 (16 days); 2020005 Moxifloxacin 5mg/mL Solution Injection 10/9/2019 3/30/2020 (170 days); 2020081 Dexamethasone (1mg/mL)-Moxifloxacin (5mg/mL) Solution Injection 10/4/2020 11/12/2020 (38 days). In addition, the following Adverse Event Reports received in 2018-2019 were not reported to FDA in 15 calendar days after first receiving information about the adverse event. The following Adverse Events were retrospectively investigated in response to the Warning Letter the firm received in 2019. Each retrospective complaint investigation which was determined to be an adverse drug event was reported to the FDA in 2020 upon completion of the firm's investigation. ADE Number Product Lot Number ADE Received ADE Reported to FDA** 2020020 Triamcinolone (15mg/mL)/Moxifloxacin (1mg/mL) Suspension Injection and Prednisolone/Gatifloxacin-Bromfenac Suspension (b) (4) 5/16/2019 7/9/2020; 2020021 Moxifloxacin 5mg/mL Solution Injection 3/26/2019 7/9/2020; 2020022 Dexamethasone (1mg/mL)/Moxifloxacin (5mg/mL) Solution Injection 2/18/2019 7/9/2020; 2020023 Prednisolone (1%)/Bromfenac (0.075%) Suspension 5/2/2019 7/9/2020; 2020024 Triamcinolone (15mg/mL)/Moxifloxacin (1mg/mL) Suspension Injection (b) (4) 5/20/2019 7/9/2020; 2020025 Dexamethasone (1mg/mL)/Moxifloxacin (5mg/mL) Solution Injection 6/24/2019 7/9/2020; 2020027 Midazolam/Ketamine/Ondansetron (3/25/2) mg Troche 5/29/2019 7/9/2020; 2020028 Triamcinolone (15mg/mL)/Moxifloxacin (1mg/mL) Suspension Injection 11/6/2018 7/9/2020; 2020029 Prednisolone (1%)/Moxifloxacin (0.5%)/Nepafenac (0.075%) Suspension 7/15/2019 7/9/2020. **reported after retrospective investigation following the last FDA inspection.
- Observation 5
Quality unit lacks authority to reject
(REPEAT OBSERVATION) The quality control unit lacks the responsibility and authority to reject all in process materials and drug products. Specifically, During inspectional walkthrough on 09/29/2020, 11 lots of expired compounded sterile drug products were found on "HOLD" status in the Distribution Room #(b) (4) for released product. Part Number (b) (4) Part Description Triamcinolone Acetonide (15 MG)/Moxifloxacin Hydrochloride (1mg/mL) Lot Number (b) (4) Quantity in Quarantine 3 vials Expiry Date 07/02/2020 Days Expiration Overdue 88; (b) (4) Prednisolone Sodium Phosphate (1%)/Bromfenac (0.075%) - 20 5mL Bottles/Box 105 boxes 12/06/2019 297; (b) (4) Prednisolone Acetate/Moxifloxacin/Nepafenac (1/0.5/0.1)% 5 mL Bottles 20 per box 96 boxes 04/27/2020 154; (b) (4) Prednisolone Acetate/Moxifloxacin/Nepafenac (1/0.5/0.1)% 5 mL Bottles 20 per box 98 boxes 08/22/2020 37; (b) (4) Prednisolone Acetate/Moxifloxacin/Nepafenac (1/0.5/0.1)% 5 mL Bottles 20 per box 87 boxes 08/22/2020 37; (b) (4) Prednisolone Acetate/Moxifloxacin/Nepafenac (1/0.5/0.1)% 5 mL Bottles 20 per box 99 boxes 08/23/2020 36; (b) (4) Prednisolone Acetate/Moxifloxacin/Nepafenac (1/0.5/0.1)% 5 mL Bottles 20 per box 100 boxes 07/27/2020 63; (b) (4) Prednisolone - Nepafenac Ophthalmic Drops (1/0.1)% (5 mL) Box of 20 Bottles (b) (4) 52 boxes 06/08/2020 112; (b) (4) Prednisolone - Nepafenac Ophthalmic Drops (1/0.1)% (5 mL) Box of 20 Bottles 63 boxes 06/22/2020 98; (b) (4) Prednisolone - Nepafenac Ophthalmic Drops (1/0.1)% (5 mL) Box of 20 Bottles 63 boxes 07/08/2020 82; (b) (4) Prednisolone - Nepafenac Ophthalmic Drops (1/0.1)% (5 mL) Box of 20 Bottles 96 boxes 07/10/2020 80. The expired lots are required to be rejected and documented according to SOP #PRD-GEN-NJR-009, Compounded Drug Product Release and Reporting to FDA, Section 6.12. (b) (4) " Once rejected, it will be prepared for destruction according to SOP #SCM-GEN-NJR-007, Material Destruction Procedure. However, SOP SCM-GEN-NJR-007 does not provide a timeline for disposition or instructions on how the expired material should be removed from Released Product Distribution Room #(b) (4) and prepared for destruction. The firm does not have clear procedures in place to monitor the product in the distribution center for expiry or have specific instructions for Quality to update a disposition to Rejected. In addition, the firm's current material management procedures do not have any provision for tracking inventory of expired materials. Furthermore, 5 unlabeled totes with sterile drug products were found in the same room on 9/29/2020 as summarized below: Totes 1-3 UNLABELED Klarity-C (Cyclosporine) Emulsion Eye Drops, (b) (4), (b) (4) units (b) (4) bags with (b) (4) units per bag finished product to be distributed to (b) (4). Totes 4-5 UNLABELED Multiple single unit finished product, left over, not packaged in (b) (4) boxes Miscellaneous products and lot numbers, including: Prednisolone/Moxifloxacin/Nepafenac; Prednisolone/Moxifloxacin/Bromfenac; Triamcinolone/Moxifloxacin; Moxifloxacin; Tropicamide/Phenylephrine; Klarity-C; Tropicamide/Proparacaine/Phenylephrine/Ketorolac; and other products. The firm has no specific procedures to dictate how individual totes with multiple left over finished compounded products are handled. In addition, the firm has no written procedures to dictate the final disposition of unreleased left-over compounded drug products.
- Observation 6
Lack of sanitation cleaning procedures
There is a lack of written procedures assigning responsibility, providing cleaning schedules describing in sufficient detail the methods, equipment and materials to be used for sanitation. Specifically, The current facility certification is provided by an external contractor. The firm's quality unit is not involved in the review, and approval of the firm's facility certification. No written procedures are established to cover this task. For example, Return Air ducts in all production rooms including ISO 5, ISO 7, and ISO 8 are not covered during the facility certification process. During inspectional walkthrough on 10/06/2020, return air duct in Room #(b) (4) (ISO 7) was found visibly dirty with unknown residue. The firm was on active shut down from (b) (4), where facility cleaning and certification took place. In addition, there is no established frequency for preventative maintenance and no records are available for cleaning of air ducts on periodic basis. The firm's Preventative Maintenance Program for facilities and manufacturing is incorporated in (b) (4) Management Software. It was noted that (b) (4) Management Software Installation Qualification (IQ) was completed in (b) (4), however, post implementation of Software, a PQ was not performed. The firm's SOP #EQU-UMR-NJR-007, Cleaning, Disinfection, and Sterilization of Classified Areas and Equipment, in 6.4 provides Cleaning Frequency Table for (b) (4) cleaning equipment and areas in ISO5, ISO7 and ISO 8, which includes floors, wall, ceiling, and other surfaces and equipment. However, neither Preventative Maintenance Program SOP # FAC-GEN-NJR-012 nor SOP #EQU-UMR-NJR-007, Cleaning, Disinfection, and Sterilization of Classified Areas and Equipment include air duct cleaning.
- Observation 7
Inadequate laboratory sampling plans
(REPEAT OBSERVATION) Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, the number of units analyzed for endotoxin testing is not representative of the entire commercial batch size. Four examples of compounded sterile drug products are listed below: a) Moxifloxacin intraocular injection (0.5%) (5mg/mL), lot #(b) (4) had a batch size of (b) (4) units released for commercial distribution. The sample size for sterility was (b) (4) vials and (b) (4) vial was analyzed for endotoxin testing. b) Prednisolone Acetate/Bromfenac ophthalmic drops (1/0.075)%, lot #(b) (4) had a batch size of (b) (4) units released for commercial distribution. The sample size for sterility was (b) (4) bottles and (b) (4) bottle was analyzed for endotoxin testing. c) Dexamethasone/Moxifloxacin intraocular injection (1/5 mg/ml), lot #(b) (4) had a batch size of (b) (4) units released for commercial distribution. The sample size for sterility was (b) (4) vials and only (b) (4) vials were analyzed for endotoxin testing. d) Prednisolone Acetate/Moxifloxacin/Bromfenac ophthalmic drops (1/0.5/0.075)%, lot #(b) (4), had a batch size of (b) (4) units released for commercial distribution. The sample size for sterility testing was (b) (4) bottles and only (b) (4) bottles was analyzed for endotoxin testing.
- Observation 8
Compounding withdrawn unsafe Bromfenac products
Your outsourcing facility compounds drug products that have been withdrawn or removed from the market because such drugs or components of such drugs have been found to be unsafe or not effective. Specifically, Your firm compounded the following drug products as topical ophthalmic suspension drugs with Bromfenac Sodium as an active ingredient. Approximately (b) (4) lots were manufactured since October 2017. Approximately (b) (4) lots were released to commercial distribution. Product (Suspension Eye Drops) Prednisolone Acetate/Bromfenac (1/0.075)% Product Code (b) (4) (discontinued) No. of Lots Compounded (b) No. Lots Released (b) Fill Volume 3.5 mL; Prednisolone Acetate/Bromfenac (1/0.075)% (b) (4) (discontinued) (b) (4) (b) (4) 3.5 mL; Prednisolone Acetate/Bromfenac (1/0.075)% (b) (4) (b) (4) (b) 5 mL; Prednisolone Acetate/Moxifloxacin/Bromfenac (1/0.5/0.075)% (b) (4) (b) (4) (b) (4) 5 mL; Prednisolone Acetate/Moxifloxacin/Bromfenac (1/0.5/0.075)% (b) (4) (b) (4) (b) 8 mL.
- Observation 9
Compounding essentially copies of approved drugs
You compound drugs that are essentially a copy of one or more approved drugs within the meaning of sections 503B(a)(5) and 503B(d)(2). Specifically, You compound drug products that: (a) are identical or nearly identical to an approved drug that is not on the drug shortage list in effect under section 506E at the time of compounding, distribution, and dispensing; or (b) are not identical or nearly identical to an approved drug but contain a bulk drug substance that is also a component of an approved drug, and for which there is no change that produces for an individual patient a clinical difference, as determined by the prescribing practitioner, between the compounded drug and the comparable approved drug. Examples of compounded drug products that are essentially a copy of one or more approved drugs include: Drug Name (Product Code) Product Strength Dosage Form Route of Administration Moxifloxacin ((b) (4)) 1 mg/mL Solution/Injections Intraocular; Moxifloxacin ((b) (4)) 5 mg/mL Solution/Injections Intraocular; Epinephrine/Lidocaine ((b) (4)) 0.25/7.5 mg/ml Solution/Injections Intraocular; Prednisolone Acetate ((b) (4)) 1% Suspension/Drops Ophthalmic; Cyclosporine ((b) (4)) 0.10% Emulsion/Drops Ophthalmic; Phenylephrine/Lidocaine ((b) (4)) 15/10 mg/ml Solution/Injections Intraocular; Prednisolone Acetate/Bromfenac ((b) (4)) 1/0.075% Suspension/Drops Ophthalmic; Tropicamide/Proparacaine/Phenylephrine Ketorolac ((b) (4)) 1/0.5/2.5/0.5% Solution/Drops Ophthalmic; Tropicamide/Phenylephrine ((b) (4)) 1/2.5% Solution/Drops Ophthalmic; Prednisolone Acetate/Moxifloxacin/Nepafenac ((b) (4)) 1/0.5/0.1% Suspension/Drops Ophthalmic; Dexamethasone/Moxifloxacin ((b) (4)) 1/5 mg/ml Solution/Injections Intraocular; Triamcinolone/Moxifloxacin ((b) (4)) 15/1 mg/ml Suspension/Injections Intraocular; Dexamethasone/Moxifloxacin/Ketorolac ((b) (4)) 1/0.5/0.4 mg/ml Solution Injections Intraocular.
- Observation 10
Annual product reviews not performed
Records are not maintained so that data therein can be reviewed (b) (4) to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures. Specifically, The firm has not generated (b) (4) product reviews for 17 out of (b) (4) current compounded active drug products released in commercial distribution. The firm has failed to follow the applicable procedures for (b) (4) product review delineated in SOP # AUD-POL-NJR-001, (b) (4) Product Quality Review. The following are the only (b) (4) Product Reviews completed since 2017: Product Code (b) (4) Product Name Dexamethasone (1mg/ml)-Moxifloxacin (5mg/mL) Solution Injection (b) (4) Time Frame Product Status Active; (b) (4) Prednisolone(1%)-Gatifloxacin(0.5%) Suspension Drops Discontinued (August 2019); (b) (4) Triamcinolone Acetonide (15mg/ml)-Moxifloxacin HCl (1mg/ml) Suspension Injection Active; (b) (4) Moxifloxacin (5mg/ml) Injection Active; (b) (4) Dexamethasone (1mg/ml)-Moxifloxacin (0.5mg/ml)-Ketorolac (0.4mg/ml) Solution Injection Active; (b) (4) Hyaluronidase (175units/ml) PF, Solution Injection Discontinued (March 2020); (b) (4) Phenylephrine (15mg/ml)-Lidocaine (10mg/ml) Solution Injection Active; (b) (4) Epinephrine (0.25mg/ml)-Lidocaine (7.5mg/ml) Solution Injection Active.
- Observation 11
Failed to report compounded drugs semiannually
Your outsourcing facility did not submit a report to FDA identifying the drugs compounded during the previous six-month period. Specifically, the following product, Klarity PF, Product Code (b) (4), Solution, Ophthalmic Eye Drops, was compounded and not identified on your report dated June 2020, or December 2020 report.
- Observation 12
Using unauthorized bulk drug substance
Your outsourcing facility compounds drug products using bulk drug substances that cannot be used in compounding under section 503B because they (a) are not used to compound drug products that appear on the drug shortage list in effect under section 506E of the Act and (b) do not appear on a list developed by FDA of bulk drug substances for which there is a clinical need. Specifically, Chondroitin Sodium is listed as an ingredient in Klarity PF, Product Code (b) (4), Solution, Ophthalmic Eyedrops.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Environmental monitoring deficiencies
OBSERVATION 1 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. The following batches of ophthalmic sterile drug products that were manufactured, released, and distributed to the market were not environmentally monitored for non-viable and viable airborne particles during manufacturing operations; the [illegible] were not operational. Additionally, the media fill operations of the below lots were also not environmentally monitored for non-viable and viable airborne particle counts. Product Prednisolone (1.0%)/Gatifloxacin (0.5%)/Nepafenac (0.1%) (PGN) - Droppers Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL) (TM) - vials for injection Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL)/Vancomycin (10 mg/mL) (TMV) - vials for injection Media Fills - Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL), [illegible] with regard to foreign particles. - Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL), [illegible] with regard to a patient who developed endophthalmitis and clinical laboratory.
- Observation 2
Inadequate smoke study/airflow validation
OBSERVATION 2 Procedures designed to prevent microbiological contamination are deficient, including the validation of the sterilization process. Specifically, the smoke study of the ISO 5 laminar air flow hood failed to demonstrate that the HEPA filtered air supply can maintain aseptic conditions. a. The initial visualization of the unidirectional air flow (smoke study) for the ISO 5 laminar airflow hood during [illegible] was not provided during the inspection. b. The air flow pattern visualization (smoke study) conducted [illegible] activities, such as product filling and manipulation by operators in the laminar air flow hood. The smoke study was conducted without the [illegible] that holds the bulk product while [illegible] and failed to demonstrate a continued pattern of unidirectional airflow.
Show observations 3 to 12
- Observation 3
Deficient cleaning/disinfection procedures
OBSERVATION 3 Written procedures for cleaning and maintenance fail to include description of materials used. Specifically, cleaning procedure EQU-UMR-NJR-007, Cleaning, Disinfection, and Decontamination of Clean Rooms and Equipment, fails to describe sufficient methods to clean and disinfect the laminar air flow hood (ISO 5), and fails to describe the method used to clean various fixtures, doors, and piping located on the wall. In addition, the effectiveness of the sanitization procedures before and after cleaning and disinfection of the ISO 7 and laminar airflow hood (ISO 5) areas has not been demonstrated through surface samples.
- Observation 4
Insufficient complaint investigations
OBSERVATION 4 There is a failure to thoroughly review any unexplained discrepancy whether associated with the manufacture or distribution of drug products. Specifically, thorough investigations for the following customer complaints were not conducted and corrective actions were not implemented or documented. a. On 04/04/2017, a consumer complaint reported the presence of black/grey particles in Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL), lot numbers JAN026 and FEB011, which were commercially distributed to approximately [illegible] customers. Non-viable and viable airborne particle counts during the filling operation were not monitored because the [illegible] and the [illegible] were not operational. Additionally, the retain samples were not evaluated to determine if they were contaminated with particles. The investigation into Lot JAN026 was not extended to other batches that were also processed without non-viable and viable airborne particle monitoring. The black/grey particles were not analyzed by a laboratory to determine their identity. The cause was not identified and corrective and preventive actions were not put into place. b. On 04/28/2017, a consumer complaint reported the presence of [illegible] in Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL), lot number [illegible], which was distributed to approximately [illegible] customers without environmental monitoring of non-viable and viable airborne particle counts during the filling operation because the [illegible] were not operational. The retain sample was not evaluated to determine if it was contaminated with particles. The action to obtain the vials with particles was not completed as of 05/30/2017 despite receiving the complaint over 1 month ago. No corrective and preventive actions were put into place. c. In March 2017, Moxifloxacin 5 mg/mL (0.5%) Injectable lot MAR034 designated as the first validation lot was manufactured and rejected due to unknown crystallization present in the process. The visual inspection was stopped, the batch record was not finished, no investigation was initiated, and no root cause has been determined. The second Moxifloxacin 5 mg/mL validation lot MAR035 was manufactured using an identical process as MAR034, released, and commercially distributed to the market without assurance that it might not be impacted by the same root cause.
- Observation 5
Missing production/process control procedures
OBSERVATION 5 There are no written procedures for production and process controls to assure the identity, strength, quality, and purity they purport or are represented to possess. Specifically, there is no established procedure that details how to conduct the I (D) (4) test for Moxifloxacin 5 mg/mL (0.5%) Injectable as well as what equipment and materials are needed for the test. The gauge of the [illegible] used to perform this test is not calibrated and there is no established calibration procedure.
- Observation 6
Poor personnel sanitation/hygiene
OBSERVATION 6 Production personnel were not practicing good sanitation and hygiene. Specifically, on 04/26/2017, during the filling operation for Prednisolone (1.0%)/Gatifloxacin (0.5%)/Nepafenac (0.1%) - Droppers lot APR024, we observed on two occasions personnel move from the ISO 7 to the ISO 5 area without spraying their gloved hands with sterile [illegible].
- Observation 7
Incoming container/closure examination lacking
OBSERVATION 7 Examination of a lot of a component, drug product container or closures liable to contamination with extraneous adulterant is deficiently examined against established specifications for such contamination. Specifically, there is no assurance that the incoming plastic bottles sterilized following finished drug products are free of (b)(4) testing or have documentation to show that they are free. • Prednisolone (1.0%)/Gatifloxacin (0.5%)/Nepafenac (0.1%) • Prednisolone (1.0%)/Gatifloxacin (0.5%) - Droppers • Prednisolone (1.0%)/Nepafenac (0.1%) - Droppers
- Observation 8
API identity not verified
OBSERVATION 8 The identity of each component of a drug product is not verified by conducting specific identity tests if they exist. Specifically, the following lots of API were used to manufacture sterile drug products without having a certificate of analysis from the supplier and their identification was not verified. a. Vancomycin Hydrochloride, lot number [illegible], used in Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL)/Vancomycin (10 mg/mL) drug product was commercially distributed in [illegible]. b. Vancomycin Hydrochloride, lot number [illegible], used in Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL)/Vancomycin (10 mg/mL) lot numbers JAN022, JAN023, FEB006, FEB007, and FEB008. These finished drug products were distributed in March 2017.
- Observation 9
Contract lab capabilities not assured
OBSERVATION 9 Adequate lab facilities for testing and approval or rejection of finished drug products and media fills are not assured. Specifically, contract laboratory facilities have not been audited for suitability for testing of drug products and media fills: a. There are no agreements or procedures in place (chemical and microbiological) to inform Imprimis about issues that occur during laboratory testing such as deviations and out of specification (OOS) results. b. There is no assurance that the contract laboratory used for sterility and endotoxin testing for Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL)/Vancomycin (10 mg/mL) Injectable lot numbers [illegible] and endotoxin testing for Prednisolone (1.0%)/Gatifloxacin (0.5%)/Nepafenac APR024 has the capability to perform the required testing. c. There is no assurance that the contract laboratory used for the determination and identification of microbiological growth in media fill batches (e.g., JAN025, FEB061, MAR002, and MAR003) can perform the analyses in an accurate, precise, and reliable way.
- Observation 10
Inadequate sampling and lab controls
OBSERVATION 10 Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, the number of finished product samples taken per batch is dictated by the contract laboratory. There is no Imprimis procedure or sampling plan that is used to determine if a representative quantity of drug product was taken. The following sterile drug products were involved and Staphylococcus epidermidis was identified by a hospital clinical laboratory. a. Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL) (lot JAN021) distributed to the market to approximately [illegible] customers. The sample size for chemical analysis (potency) was [illegible] vials; the sample size for sterility and endotoxin testing was [illegible] vials. b. Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL) (lot JAN026) distributed to the market to approximately [illegible] customers. The sample for chemical analysis (potency) was [illegible] vials; the sample size for sterility and endotoxin testing was [illegible] vials. c. Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL) (lot FEB036) distributed to the market to approximately [illegible] customers. The sample for chemical analysis (potency) was [illegible] vials; the sample size for sterility and endotoxin testing was [illegible] vials. d. Triamcinolone (15 mg/mL)/Moxifloxacin HCl (1 mg/mL) (lot FEB037) distributed to the market to approximately [illegible] customers. The sample for chemical analysis (potency) was [illegible] vials; the sample size for sterility and endotoxin testing was [illegible] vials.
- Observation 11
Container closure supplier not qualified
OBSERVATION 11 Establishment of the reliability of the container closure supplier's report of analysis (COA) has not been appropriately validated at appropriate intervals. Specifically, the suppliers of the following container closure systems have not been qualified or audited. In addition, there has not been any testing conducted of these containers and closures to demonstrate reliability of the supplier's COA. a. The supplier that provides the 2 mL amber vials and [illegible]. b. The supplier that provides the plastic bottles and [illegible].
- Observation 12
Quality unit lacked authority/actions
OBSERVATION 12 The quality control unit lacks the responsibility and authority to approve or reject all packaging material. Specifically, the quality unit failed to identify discrepancies in [illegible] lot numbers [illegible] and [illegible] used for sterile drug products containing Prednisolone. The label indicates sterilization by (b)(4); however, during the inspection, the supplier stated that the sterilization method was actually (b)(4). On 05/10/2017, we observed the above deficiency which had not been identified during the incoming inspection and release of this component. No explanation regarding the discrepancy in sterilization methods was provided.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Mar 11, 2026. Each one asked for a Form 483.
Inspection ending Apr 3, 2024OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jun 6, 2024FDA-FOIA-2024-4969Form 483· 1 of 4 sitesClosed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Mar 11, 2026FDA-FOIA-2026-2389Form 483 + EIRClosed, no reply from requester
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013024146 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013024146. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.