Skip to content

Strive Pharmacy Texas LLC dba Strive Pharmacy

1430 S Main St Ste 105, Boerne, Texas, United States

FEI 3015826784

FDA has 3 inspections on file for Strive Pharmacy Texas LLC dba Strive Pharmacy in Boerne, Texas (FEI 3015826784), from 2020 to 2023. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection. They are listed below. One FOIA request has asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER · Office of Pharmaceutical Quality Operations, Division II). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2020–2023
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
1 request, latest Nov 7, 2023
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Failure to clean and disinfect/sterilize equipment, ISO 5 area

      Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.

    2. FDCA 501(a)(2)(A)

      Facility design, influx of lesser quality air

      The facility design was observed to allow the influx of lesser quality air into a classified area containing higher quality air.

    3. FDCA 501(a)(2)(A)

      Personnel exposure during aseptic manipulations

      Personnel performed aseptic manipulations with exposed hair or skin.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Facility airflow and integrity problems

      OBSERVATION #1 Your facility design may allow the influx of poor quality air into a higher classified area. Specifically, A. The I (5) (4) used to separate the ISO 5 area from the ISO 7 room is attached to the top of the ISO 5 area with double sided mounting strips. A visible gap was observed between the ceiling and the r (o) (4) l where the mounting strips are attached. There is no assurance that the current configuration prevents the ingress of ISO 7 air into the ISO 5 area. B. OCo) (4) ,_J doors are designed with no safeguards in place to detect and notify of changes in differential pressure in the event that the doors are opened simultaneously. C. A crack was observed in the r(b) (4) l wall of the ISO 7 cleanroom thereby allowing the possible ingress of air from the ISO 8 area. D. A power cord from the i(l5f(4) I in the ISO 8 area was connected to an outlet inside the ISO 7 cleanroom through one of the exhaust vent flaps. In this case, the vent was unable to fully close due to obstruction from the cord. In addition, dust was observed in the ISO 8 area in close proximity to the vent flaps thereby allowing possible ingress into the ISO 7 cleanroom.

    2. Observation 2

      Inadequate hazardous drug containment

      OBSERVATION #2 You produced hazardous drugs without providing adequate containment and segregation to prevent cross contamination. Specifically, your ISO 5 Biological Safety Cabinet used for the compounding of hazardous sterile drug products is located in the ISO 7 cleanroom in close proximity to the ISO 5 workbench area.

    Show observations 3 to 6
    1. Observation 3

      HEPA grille had dark residue

      OBSERVATION #3 On 10/27/2021, I observed a dark residue on the plastic grille enclosing the HEPA filter located in the ISO 5 workbench area.

    2. Observation 4

      Materials not re-disinfected before use

      OBSERVATION #4 Materials and supplies were not disinfected prior to entering the aseptic processing areas. Specifically, on 10/25/2021, during the aseptic processing of MICB12 15/50/100/1 mg/ml Injectable, lot # 10252021@1, I observed that the operator sanitized the surface of a package containing a vent needle and placed it on the stainless steel table outside the ISO 5 area. After about 10 minutes, the package containing the vent needle was used in the ISO 5 area without being re-sanitized.

    3. Observation 5

      Inadequate ISO 5 certification/smoke studies

      OBSERVATION #5 The certification of the ISO 5 areas was inadequate. Specifically, A. Smoke studies were not conducted on the ISO 5 Biological Safety Cabinet to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions. B. Smoke studies within the ISO 5 classified area failed to demonstrate adequate product protection. Specifically, the smoke generator was not positioned properly to allow an assessment of airflow to the critical area where aseptic operations were being simulated.

    4. Observation 6

      Inadequate media fill simulation

      OBSERVATION #6 Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your current media fill test using a (b)(4) [illegible] consists of aseptically transferring (I:>) (4) into a mini bag. Review of media fills conducted since 8/2020 revealed that the media fills were not representative in that your firm failed to simulate actual production processes. For example, a lot of Methylcobalamin 1 mg/ml, lot # 10132021@4 consisted of (b)<>ml, or (b) (4) ml vials.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Aseptic practice breaches

      In regard to aseptic practice: A. On 1/23/20, during the aseptic processing of MicB Complex Injectable, lot #01232020@1, the operator was observed placing his gloved hands outside the ISO 5 workbench area to retrieve supplies. Upon re-entry into the ISO 5 workbench area with the supplies, he failed to re-sanitize his hands. B. On 1/23/20, during the (b)(4) of Methylcobalamin 1mg/ml for Injection, lot #01232020@2, I (Stephen Brown) noted that the pharmacist was performing the (b)(4) and filling of a vial outside the ISO 5 workbench area. C. I (Stephen Brown) noted that sterile wipes, stoppers, and vials were stored in the ISO 7 cleanroom in original packaging which was open to the environment.

    2. Observation 2

      Beakers not depyrogenated

      The glass beakers used in the production of sterile, injectable drug products are not depyrogenated prior to use. The glass beakers are cleaned with household detergent, washed in a dishwasher, and stored uncovered in a drawer prior to use. The same beakers are also used in the production of hazardous, non-sterile drug products.

    Show observation 3
    1. Observation 3

      HEPA filter residue observed

      On 1/24/20, I (Stephen Brown) observed brownish residue on a corner of the HEPA filter located in the ISO 5 workbench area.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Nov 7, 2023. It asked for a Form 483.

  • Inspection ending Sep 8, 2023OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Nov 7, 2023FDA-FOIA-2023-9905Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3015826784 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3015826784. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.