Skip to content

Vita Pharmacy, LLC dba Talon Pharmacy of Boerne Form 483, November 2021

FDA issued this Form 483 to Vita Pharmacy, LLC dba Talon Pharmacy of Boerne in Boerne, Texas (FEI 3015826784) at the end of a drug inspection that ended November 2, 2021. It lists 6 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on August 30, 2022.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Feb 4, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Nov 2, 2021
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Feb 4, 2022
94 days after the inspection
Facility
FEI 3015826784
Boerne, Texas

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Facility airflow and integrity problems

    OBSERVATION #1 Your facility design may allow the influx of poor quality air into a higher classified area. Specifically, A. The I (5) (4) used to separate the ISO 5 area from the ISO 7 room is attached to the top of the ISO 5 area with double sided mounting strips. A visible gap was observed between the ceiling and the r (o) (4) l where the mounting strips are attached. There is no assurance that the current configuration prevents the ingress of ISO 7 air into the ISO 5 area. B. OCo) (4) ,_J doors are designed with no safeguards in place to detect and notify of changes in differential pressure in the event that the doors are opened simultaneously. C. A crack was observed in the r(b) (4) l wall of the ISO 7 cleanroom thereby allowing the possible ingress of air from the ISO 8 area. D. A power cord from the i(l5f(4) I in the ISO 8 area was connected to an outlet inside the ISO 7 cleanroom through one of the exhaust vent flaps. In this case, the vent was unable to fully close due to obstruction from the cord. In addition, dust was observed in the ISO 8 area in close proximity to the vent flaps thereby allowing possible ingress into the ISO 7 cleanroom.

  2. 2

    Inadequate hazardous drug containment

    OBSERVATION #2 You produced hazardous drugs without providing adequate containment and segregation to prevent cross contamination. Specifically, your ISO 5 Biological Safety Cabinet used for the compounding of hazardous sterile drug products is located in the ISO 7 cleanroom in close proximity to the ISO 5 workbench area.

  3. 3

    HEPA grille had dark residue

    OBSERVATION #3 On 10/27/2021, I observed a dark residue on the plastic grille enclosing the HEPA filter located in the ISO 5 workbench area.

  4. 4

    Materials not re-disinfected before use

    OBSERVATION #4 Materials and supplies were not disinfected prior to entering the aseptic processing areas. Specifically, on 10/25/2021, during the aseptic processing of MICB12 15/50/100/1 mg/ml Injectable, lot # 10252021@1, I observed that the operator sanitized the surface of a package containing a vent needle and placed it on the stainless steel table outside the ISO 5 area. After about 10 minutes, the package containing the vent needle was used in the ISO 5 area without being re-sanitized.

  5. 5

    Inadequate ISO 5 certification/smoke studies

    OBSERVATION #5 The certification of the ISO 5 areas was inadequate. Specifically, A. Smoke studies were not conducted on the ISO 5 Biological Safety Cabinet to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions. B. Smoke studies within the ISO 5 classified area failed to demonstrate adequate product protection. Specifically, the smoke generator was not positioned properly to allow an assessment of airflow to the critical area where aseptic operations were being simulated.

  6. 6

    Inadequate media fill simulation

    OBSERVATION #6 Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your current media fill test using a (b)(4) [illegible] consists of aseptically transferring (I:>) (4) into a mini bag. Review of media fills conducted since 8/2020 revealed that the media fills were not representative in that your firm failed to simulate actual production processes. For example, a lot of Methylcobalamin 1 mg/ml, lot # 10132021@4 consisted of (b)<>ml, or (b) (4) ml vials.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3015826784, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.