Skip to content

Med Shop Total Care Inc.

470 E Loop 281, Longview, Texas, United States

FEI 3002835459

FDA has 3 inspections on file for Med Shop Total Care Inc. in Longview, Texas (FEI 3002835459), from 2018 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published one citation from this inspection. It is listed below.

The most recent OAI inspection ended on Jul 27, 2021. FDA has issued 2 warning letters under this FEI, the latest on (CDER · Office of Pharmaceutical Quality Operations, Division II). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2018–2023
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
1 request, latest Sep 12, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 citation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Lack of/inadequate, environmental monitoring

      Lack of routine environmental monitoring in the classified areas.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate response to microbial contamination

      You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, you had several environmental monitoring results in the ISO 5 environment where you did not identify the microorganism and continued to produce and distribute sterile drug products without a complete investigation and corrective action taken. Surface EM - Human 4 6/3/2021 2 cfu ISO5 (b)(4) center of LFH Fingertips - Human 5/25/2021 4 cfu Left hand 6/18/2021 1 cfu Right hand (b)(6) 6/21/2021 1 cfu Left hand Fingertips - Human 3/19/2021 1 cfu Left hand (b)(6) 4/16/2021 1 cfu Right hand 4/16/2021 1 cfu Left hand 4/16/2021 2 cfu Right hand 4/19/2021 1 cfu Left hand 4/19/2021 1 cfu Right hand 4/20/2021 3 cfu Left hand 4/20/2021 1 cfu Right hand 5/10/2021 3 cfu Left hand 5/10/2021 2 cfu Right hand 5/17/2021 1 cfu Left hand 5/19/2021 2 cfu Left hand 5/20/2021 1 cfu Left hand 6/9/2021 3 cfu Right hand 6/10/2021 1 cfu Right hand 6/15/2021 1 cfu Left hand 6/16/2021 2 cfu Left hand 6/16/2021 1 cfu Left hand 6/18/2021 1 cfu Left hand 6/18/2021 1 cfu Right hand 6/21/2021 3 cfu Left hand 6/23/2021 1 cfu Left hand 6/23/2021 1 cfu Left hand **This is a repeat observation.**

    2. Observation 2

      Poor facility air control / loss of pressure

      Your facility design allowed the influx of poor-quality air into a higher classified area. Specifically, a) You replaced the condenser and air handler to the sterile suite on the human side on June 25, 2021 and loss of pressure beginning Friday, 6/25/21 in (b)(4) room at 11:38 am until 06/27/21 at 14:00. You performed cleaning with (b)(4) on Monday, 6/28/21 after the installation but did not recertify the human side and continued to produce and distribute sterile drugs. b) Doors between rooms are not fully closed to prevent air flow between classified areas.

    Show observations 3 to 7
    1. Observation 3

      Non-microbial contamination on HEPA screen

      Non-microbial contamination was observed in your production area. Specifically, the metal screen in front of the HEPA filter for hood, identified as (b)(4), has brownish residue on the lower left portion.

    2. Observation 4

      Insufficient disinfectant dwell time and coverage

      Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, during the [illegible] cleaning of the clean room I observed on July 9, 2021, the dwell time for [illegible] solution made with (b)(4) does not stay wet for the recommended labeled time of (b)(4) on LFHs (CTSO 5): carts, walls and floors and other items located in the ISO 7 area allowing a dwell time of less than (b)(4).

    3. Observation 5

      Gloved personnel touched non-sterile surfaces

      Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves. Specifically, on July 6, 2021, I observed personnel touch the keyboard or other surfaces multiple times located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves.

    4. Observation 6

      Inadequate media fill simulation

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, a) Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. You do not include the largest batch size and different container types (vials). b) The employee who produces the bulk intermediate sterile vials of Baclofen, Bupivacaine, Clonidine, Fentanyl, Hydromorphone and Morphine Sulfate last performed a media fill of this type on February 21, 2020. **This is a repeat observation.**

    5. Observation 7

      Release of product with sterility failure

      Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, after notification from your contract laboratory of a sterility failure for bulk intermediate vial of Bupivacaine [illegible], lot (b)(4), you recalled drug products that contained this lot.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be pyrogen-free is not laboratory tested to determine conformance to such requirements.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    4. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    5. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    Show 5 more citations
    1. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    2. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    3. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform.

    4. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Sep 12, 2025. It asked for a Form 483.

  • Inspection ending Jul 27, 2021OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Sep 12, 2025FDA-FOIA-2025-10866Form 483Directed Requester to Publically Available Information

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 9

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002835459 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002835459. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.