ImprimisRx NJ
1705 Us Highway 46 Ste 4, Ledgewood, New Jersey, United States
FEI 3003348498
FDA has 6 inspections on file for ImprimisRx NJ in Ledgewood, New Jersey (FEI 3003348498), from 2013 to 2022. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER · Division of Pharmaceutical Quality Operations I).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 7 citations from this inspection. They are listed below.
No court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.113(b), 21 CFR 211.166(b) and 21 CFR 211.42(c)(10)(iv).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2013–2022
- 2 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 6
- 3 posted 483s not matched to an inspection
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Inadequate sporicidal agents, cleanroom and ISO 5 area
The use of sporicidal agents in the cleanrooms and ISO 5 classified aseptic processing area was inadequate.
- FDCA 501(a)(2)(A)
Personnel habits, contamination
Personnel did not disinfect and change gloves frequently enough to prevent contamination.
- FDCA 501(a)(2)(A)
Non-microbial contamination, production area
Non-microbial contamination was observed in your production area.
- FDCA 501(a)(2)(A)
Air flow quality, higher classified area
Your facility design allowed the influx of poor quality air into a higher classified area.
- FDCA 501(a)(2)(A)
Disinfecting materials, aseptic processing area
Materials or supplies were not disinfected prior to entering the aseptic processing areas.
Show 2 more citations
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had visibly dirty equipment or surface.
- FDCA 501(a)(2)(A)
Dust-collecting overhangs, surrounding area of ISO 5
The segregated production areas surrounding the ISO 5 classified aseptic processing area contained dust-collecting overhangs without adequate and frequent cleaning.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate ISO 7 filling room construction
The ISO 7 Filling Room is not adequately constructed to ensure aseptic processing conditions. Specifically, during the cleaning of the ISO 7 Filling Room, we observed that the ceiling tiles were moving up and down when the technicians were wiping them with a mop. Within the ISO 7 Filling Room, the ISO 5 Laminar Air Flow Hood is used for the filling of sterile ophthalmic and injectable drug products.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
ISO 5 hood not certified under dynamic conditions
OBSERVATION 1 The ISO 5 laminar air flow hood was not certified under dynamic conditions. Specifically, the smoke study performed in (b) (4) all personnel and containers present The smoke study was conducted with no bulk container present, and (b) (4) did not simulate the filling ofproduct during the (b) (4) video to assess uni-directional airflow under actual conditions.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.
Containers & Closures Clean, Sterilized, Pyrogen-free
Drug product containers were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features2 of 3
- 21 CFR 211.113Control of microbiological contamination2 of 3
- 21 CFR 211.166Stability testing2 of 3
- 21 CFR 211.94Drug product containers and closures1 of 3
- 21 CFR 211.167Special testing requirements1 of 3
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations I · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003348498 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003348498. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.