Skip to content

Metro Drugs 3rd Avenue Corp

931 Lexington Ave, New York, New York, United States

FEI 3011795133

FDA has one inspection on file for Metro Drugs 3rd Avenue Corp in New York, New York (FEI 3011795133). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2019
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Non-sterile wipes used in ISO 5

      Disinfecting agents and cleaning pads or wipes used in the ISO 5 area aseptic processing areas are not sterile. Specifically, on 3/14/19, I observed an aseptic operator using non-sterile (b) (4) Wipes (b) (4), to disinfect the ISO 5 (b) (4) laminar flow hood and as a place mat where syringes, needles, and sterile (b) (4) were placed upon during aseptic filling.

    2. Observation 2

      Released drug products failing potency specifications

      Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, the following out-of-specification potency results were observed: • T3 6mcg capsules S/R, lot #01082019@9, Liothyronine Sodium (T3) potency: 86.3%; • T3 20mcg capsules S/R, lot #01252019@7, Liothyronine Sodium (T3) potency: 116%; • T3 30mcg, lot #01252019@14, Liothyronine Sodium (T3) potency: 75.0%; • Estriol/ DHEA/ Testosterone/ Pregnenolone 100mg/4mg/45mg/mg/mL, lot #02142019@1, DHEA potency: 81.3%, Estriol potency: 77.2%, and Testosterone potency: 84.5%; • Methylcobalamin 1000mcg/mL (PF) injectable, lot #02212019@1, Methylcobalamin potency: 53.3%; • Tri-Mix Quad (Alprostadil 10mcg/ Papaverine 12mg/ Phentolamine 1mg/ Atropine 0.15mg/mL), lot #03052019@6, Atropine Sulfate Monohydrate potency: 134.51%; and, Atropine 0.1% Stock Solution, lot #03052019@8, Atropine Sulfate Monohydrate potency: 107.38%. No product impact assessment has been conducted and recorded, except for the Tri-Mix Quad and Atropine 0.1% Stock Solution.

    Show observations 3 to 5
    1. Observation 3

      Inadequate media fills simulating worst-case conditions

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, a) Your firm did not evaluate any conditions that provide a challenge to aseptic operations as part of the firm's media fill. For example, operators do leave and reenter the ISO 5 area during production; however, this was not addressed in any of the media fills. b) One of your pharmacy technicians was not qualified by a media fill prior to preparing sterile drug products and continued to perform aseptic processing of sterile drug products despite failing a media fill performed on 1/17/19.

    2. Observation 4

      ISO-5 areas not certified under dynamic conditions

      ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow was not verified under dynamic conditions. The most recent smoke pattern tests were performed on (b) (4) by (b) (4) on the firm's ISO 5 biological safety cabinet and ISO 5 laminar flow clean bench under static conditions.

    3. Observation 5

      Inadequate pressure differentials between cleanrooms

      Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, pressure differential readings for (b) (4), which monitors the pressure from the ISO 7 Hazardous Prep Room to the ISO 8 Non-Hazardous Prep/Buffer Room (established negative pressure differential limit (b) (4)), were out of specification on 1/14/19 to 1/15/19, all of December 2018, and 11/1/18 to 11/27/18. Mixing of non-sterile active pharmaceutical ingredients and non-sterile commercial products is conducted in the (b) (4) hoods (b) (4) located in both the ISO 7 Hazardous Prep Room and the ISO 8 Non-Hazardous Prep/Buffer Room. No product impact assessment was conducted and recorded.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011795133 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011795133. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.