The Compounding Pharmacy Form 483, September 2021

FDA issued this Form 483 to The Compounding Pharmacy in Hickory, North Carolina (FEI 3009127876) at the end of a drug inspection that ended September 29, 2021. It lists 3 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Mar 14, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 29, 2021
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Mar 14, 2022
166 days after the inspection
Facility
FEI 3009127876
Hickory, North Carolina

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Unfiltered air entering classified areas

    Your facility design allowed the influx of poorer quality air into a higher classified area. Specifically, (b) (4) (b) (4) (b) (4) a) cleanroom and (classified ISO 7) contain a mini-split type of air conditioning (AC) unit. The presence of this equipment, containing a condenser and fan, within or in close enough proximity to the ISO 5 area could compromise the air in the ISO 5 area as they are particle generating equipment that cannot be sufficiently cleaned inside and do not provide for HEPA filtration of air moving into the classified space. b) the hole for the drain tube removing condensation from the mini-split air conditioning (AC) unit in (b) (4) cleanroom had air movement from the hole. This shows a connection between the open back of the AC unit in the ISO 7 area surrounding the ISO 5 hood, and the unclassified space in which the hole (b) (4) terminates. There is a gap between the top edge of the AC unit in cleanroom and the wall which may further indicate an unsealed connection on the back of the AC unit. (b) (4) c) I observed the drain tube for the unit in cleanroom, containing stagnant water on the unclassified side of the hole which has black deposition (particles) and a symmetrical, circular white spot inside of the drain tube. d) all of your sterile products are compounded within approximately three feet, in the case of cleanroom (b) (4) (b) (4), and within approximately eight feet, in the case of cleanroom, of these AC units. Furthermore, these units are placed parallel to the face of the ISO 5 aseptic processing area with maneuverable vents positioned such that they could potentially blow directly into the hood where sterile product including intrathecal, intravitreal, intravenous, and intramuscular products are compounded.

  2. 2

    Difficult-to-clean/dirty cleanroom equipment

    The classified aseptic processing areas had difficult to clean and/or visibly dirty equipment or surface. Specifically, (b) (4) (b) (4) a) the AC units in cleanrooms and (classified ISO 7) are surrounded on three sides with foil tape that contains adhesive to the edge. This tape is not cleanroom grade and the adhesive presents its own hazard by its non-cleanable nature. The edge of the tape appears to be darker than the tape itself, and there is evidence of water leakage from under the tape potentially providing an ideal environment for microbial growth. b) your environmental monitoring process does not sample the AC units or the surrounding tape, and your procedures do not specifically call out that the units are cleaned. (b) (4) (b) (4) (b) (4) c) cleanroom and contain a mini-split type of air conditioning (AC) unit. The equipment, containing a condenser and fan inside the units, are not cleanable without disassembly and therefore are difficult to clean. (b) (4) d) the gap at the back of the AC unit in cleanroom (approximately 0.5 – 1cm) does not allow for cleaning of the wall via a smooth easily cleanable surface.

  3. 3

    Use of non-depyrogenated equipment

    Non-depyrogenated equipment was used in sterile drug production. Specifically, glassware used in the compounding of product intended to be sterile (including (b) (4) products) was placed in a (b) (4) for depyrogenation. There is no assurance that that glassware was depyrogenated due to the lack of endotoxin indicators used in the batch of glassware. This affects all products compounded in the pre-sterile room. Furthermore, your report of values from 8/30/2021 on the (b) (4) used to depyrogenate glassware for compounding sterile product shows (b) (4) of test points as being (b) (4) with an average of (b) (4).

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.