The Compounding Pharmacy
750 4th St Sw, Hickory, North Carolina, United States
FEI 3009127876
FDA has 2 inspections on file for The Compounding Pharmacy in Hickory, North Carolina (FEI 3009127876), from 2019 to 2021. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2019–2021
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Unfiltered air entering classified areas
Your facility design allowed the influx of poorer quality air into a higher classified area. Specifically, (b) (4) (b) (4) (b) (4) a) cleanroom and (classified ISO 7) contain a mini-split type of air conditioning (AC) unit. The presence of this equipment, containing a condenser and fan, within or in close enough proximity to the ISO 5 area could compromise the air in the ISO 5 area as they are particle generating equipment that cannot be sufficiently cleaned inside and do not provide for HEPA filtration of air moving into the classified space. b) the hole for the drain tube removing condensation from the mini-split air conditioning (AC) unit in (b) (4) cleanroom had air movement from the hole. This shows a connection between the open back of the AC unit in the ISO 7 area surrounding the ISO 5 hood, and the unclassified space in which the hole (b) (4) terminates. There is a gap between the top edge of the AC unit in cleanroom and the wall which may further indicate an unsealed connection on the back of the AC unit. (b) (4) c) I observed the drain tube for the unit in cleanroom, containing stagnant water on the unclassified side of the hole which has black deposition (particles) and a symmetrical, circular white spot inside of the drain tube. d) all of your sterile products are compounded within approximately three feet, in the case of cleanroom (b) (4) (b) (4), and within approximately eight feet, in the case of cleanroom, of these AC units. Furthermore, these units are placed parallel to the face of the ISO 5 aseptic processing area with maneuverable vents positioned such that they could potentially blow directly into the hood where sterile product including intrathecal, intravitreal, intravenous, and intramuscular products are compounded.
- Observation 2
Difficult-to-clean/dirty cleanroom equipment
The classified aseptic processing areas had difficult to clean and/or visibly dirty equipment or surface. Specifically, (b) (4) (b) (4) a) the AC units in cleanrooms and (classified ISO 7) are surrounded on three sides with foil tape that contains adhesive to the edge. This tape is not cleanroom grade and the adhesive presents its own hazard by its non-cleanable nature. The edge of the tape appears to be darker than the tape itself, and there is evidence of water leakage from under the tape potentially providing an ideal environment for microbial growth. b) your environmental monitoring process does not sample the AC units or the surrounding tape, and your procedures do not specifically call out that the units are cleaned. (b) (4) (b) (4) (b) (4) c) cleanroom and contain a mini-split type of air conditioning (AC) unit. The equipment, containing a condenser and fan inside the units, are not cleanable without disassembly and therefore are difficult to clean. (b) (4) d) the gap at the back of the AC unit in cleanroom (approximately 0.5 – 1cm) does not allow for cleaning of the wall via a smooth easily cleanable surface.
Show observation 3
- Observation 3
Use of non-depyrogenated equipment
Non-depyrogenated equipment was used in sterile drug production. Specifically, glassware used in the compounding of product intended to be sterile (including (b) (4) products) was placed in a (b) (4) for depyrogenation. There is no assurance that that glassware was depyrogenated due to the lack of endotoxin indicators used in the batch of glassware. This affects all products compounded in the pre-sterile room. Furthermore, your report of values from 8/30/2021 on the (b) (4) used to depyrogenate glassware for compounding sterile product shows (b) (4) of test points as being (b) (4) with an average of (b) (4).
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Floors, walls, ceiling surfaces
Aseptic processing areas are deficient in that walls and ceilings are not smooth and/or hard surfaces that are easily cleanable.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Regulations FDA cited here
The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3009127876 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3009127876. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.