Skip to content

21 CFR 211.48: Plumbing

FDA's inspection data lists 58 Form 483 citations of 21 CFR 211.48 at 54 facilities, from January 2009 to December 19, 2025.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
58
At 56 inspections
Facilities cited
54
Distinct FEIs
Most recent citation
Dec 19, 2025
International Medication Systems Ltd.
Warning letters
0
State a violation of it

The regulation

The current text of 21 CFR 211.48 from the Electronic Code of Federal Regulations.

§ 211.48 Plumbing.

(a) Potable water shall be supplied under continuous positive pressure in a plumbing system free of defects that could contribute contamination to any drug product. Potable water shall meet the standards prescribed in the Environmental Protection Agency's Primary Drinking Water Regulations set forth in 40 CFR part 141. Water not meeting such standards shall not be permitted in the potable water system.

(b) Drains shall be of adequate size and, where connected directly to a sewer, shall be provided with an air break or other mechanical device to prevent back-siphonage.

21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart CRead on eCFR

Citations by year

Form 483 citations of 21 CFR 211.48 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 9 in 2009

Form 483 citations of 21 CFR 211.48 by inspection year
YearForm 483 citations
20099
20108
20114
20125
20133
20141
20163
20174
20183
20192
20212
20226
20233
20243
20252

How FDA words this citation

FDA's short descriptions and citation text on these 58 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Plumbing System Defects38 citations
  • Drains--Size, Back-siphonage Prevention10 citations
  • Potable water standards not met8 citations
  • Potable water not under positive pressure2 citations

Citation text

  • “The plumbing system contains defects that could contribute to the contamination of drug products.”38 citations
  • “Drains are not provided with an air break or other mechanical device to prevent back-siphonage where connected directly with a sewer.”8 citations
  • “The potable water being permitted for use in the potable water system fails to meet standards prescribed by the Environmental Protection Agency.”8 citations
  • “Drains are not of adequate size.”2 citations
Show 1 more
  • “There is a failure to supply potable water under continuous positive pressure.”2 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 211.48, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Show 4 more

Often cited at the same inspection

Of the 56 inspections where FDA cited 21 CFR 211.48, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 211.48

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.48; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.