Natural Technology LLC
350 Apache Trl, Terrell, Texas, United States
FEI 1643811DUNS 618561906
FDA has one inspection on file for Natural Technology LLC in Terrell, Texas (FEI 1643811). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is NATURAL TECHNOLOGY LLC (D-U-N-S 117571610).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2024
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Jul 30, 2024
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.
Buildings not maintained in good state of repair
Buildings used in the processing and holding of a drug product are not maintained in a good state of repair.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Show 4 more citations
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Plumbing System Defects
The plumbing system contains defects that could contribute to the contamination of drug products.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Component identity verification
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 30, 2024. Each one asked for a Form 483.
Inspection ending Mar 1, 2024VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 30, 2024FDA-FOIA-2024-6623Form 483· 1 of 4 sitesClosed
- May 9, 2024FDA-FOIA-2024-4271Form 483· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 9 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.48Plumbing1 of 1
- 21 CFR 211.58Maintenance1 of 1
- 21 CFR 211.63Equipment design, size, and location1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
Show all 9
- 21 CFR 211.192Production record review1 of 1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- NATURAL TECHNOLOGY LLCD-U-N-S 117571610
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1643811 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1643811. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.