Surgery Pharmacy Services Inc
4515 Brainerd Road Suite B, Chattanooga, Tennessee, United States
FEI 3010704905
FDA has 2 inspections on file for Surgery Pharmacy Services Inc in Chattanooga, Tennessee (FEI 3010704905), from 2019 to 2023. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 2 citations from this inspection. They are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2019–2023
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Inadequate smoke studies
Smoke studies were inadequately performed under dynamic conditions.
- FDCA 501(a)(2)(A)
Media fills, failure
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Microbial contamination, inadequate response
Actionable microbial contamination was present in production without adequate product evaluation and remedial action. Specifically, on 5/27/2019, response to Bacillus microbial contamination [illegible] the extent of impact nor identification and notification of all potentially impacted patients.
- Observation 2
Infrequent glove disinfection/change
Personnel failed to disinfect or change gloves frequently enough. Specifically, the technician was observed during preparation of TPN products on 11/18/2019. For example, she moved her hands out of the ISO5 hood and then back into the hood without sanitizing, tying out the trash bag in the large trash bin located in the ISO8 anteroom, and resuming aseptic production activities in the ISO5 hood with hands with [illegible]. She did not change her sterile gloves after contact with the trash bin. On 11/19/2019, she was also observed using a step-stool, which she uses to reach within the ISO5 hood, and did not change her sterile gloves before resuming aseptic production activities.
Show observations 3 to 10
- Observation 3
Exposed skin in critical area
Personnel engaged in aseptic processing were observed with exposed skin in critical areas. On 11/18/2019 and 11/19/2019, the technician was observed leaning significantly into the ISO5 certified hood with her forehead exposed while leaning during aseptic production activities.
- Observation 4
Materials not adequately disinfected
Equipment, materials, and/or supplies are not adequately disinfected prior to entering aseptic processing areas. Specifically, materials are not adequately disinfected to stricter classifications. Large drug components, such as [illegible], are loaded and then moved into temporary storage baskets within the pharmacy area prior to being placed into the ISO5 hood. For production, materials are placed on ISO5 worksurfaces prior to disinfection.
- Observation 5
Inadequate media fill simulations
Media fills were not performed that closely simulate appropriate, worst-case activities and conditions. Specifically, the media fills consist of preparing and [illegible] vials intended to represent finished product, though activities such as the manual production and [illegible] for intracameral injections are not represented.
- Observation 6
Non-sterile disinfectants used
Disinfecting agents used in the ISO5 area are [illegible]; [illegible] is non-sterile and is routinely used in supporting aseptic processing areas.
- Observation 7
Unverified pressure differentials
Pressure differentials between areas with different air classifications were not monitored prior to or during sterile drug production. Specifically, there is no verification of the pressure differentials before or during sterile drug production. Pressure differentials are measured with manometers which are not visible from within the cleanroom. The values are documented but not recorded [illegible].
- Observation 8
Released drug failed assay testing
Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, epinephrine solutions have failed assay testing for epinephrine since 02/2019 but they were still produced and dispensed without resolving the failures. Additionally, testing data lacks supporting documentation with the date of production to verify the solutions.
- Observation 9
Damaged, hard-to-clean hood surface
The ISO-classified equipment have difficult-to-clean surfaces. Specifically, the ISO5 hood has a worksurface composed of laminate that is stained on the left side and has been chipped on both front corner edges. This hood is used for sterile drug production and was the only hood in use through 12/2/2019.
- Observation 10
Certification not representative of operations
ISO-5 classified areas were not certified or verified under operational conditions representative of dynamic conditions. The smoke studies performed only include evaluation of the hood when not fully loaded and do not include evaluation of a fully-loaded hood, such as when equipment takes up a significant amount of space and potentially interrupts the unidirectional airflow hood design.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010704905 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010704905. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.