Buildings, facilities and HVAC in FDA Form 483 observations

The plant itself: building design and repair, air handling, pressure differentials, temperature and humidity. FDAgent finds 160 such observations in 121 Form 483s issued to 117 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
160
Each quoted below
Form 483s
121
Posted by FDA
Facilities
117
Distinct FEIs
Most recent
Sep 10, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 49 in 2026

Facilities and HVAC observations in Form 483s by inspection year
YearObservations
20081
20091
20100
20110
20121
20131
20148
20157
20164
20176
20189
20199
20202
20218
202215
20238
202418
202513
202649

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.4221 CFR 211.4421 CFR 211.4621 CFR 211.4821 CFR 211.5021 CFR 211.5221 CFR 211.58

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“HVAC” · “air handl*” · “AHU*” · “pressure differential*” · “differential pressure*” · “temperature and humidity” · “humidity control*” · “humidity monitor*” · “air change*” · “air filtration” · “state of repair” · “ceiling tile*” · “peeling” · “flaking” · “water leak*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 160 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 4

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. Personnel use non-sterile disinfectants (e.g., (b)(4)) to clean the laminar flow hoods where sterile drug products are prepared. B. No sporicidal agent is used to clean your classified areas, including the laminar flow hood where sterile drug products are prepared. C. No documentation was …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  2. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 1

    OBSERVATION 1 Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. a). Smoke studies were not performed under dynamic conditions to verify that operators, processing equipment or activities of the ISO 5 non-hazardous clean room (aka Clean Room (b)(4)) do not alter or impede the unidirectionality of air from the HEPA filters to the ISO 5 processing stations where drug …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  3. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 2

    OBSERVATION 2 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. a). Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm only monitors viable air counts (b)(4) and during the (b)(4) cleanroom certification by an outside vendor; lastly on 10/29/14. b). Environmental monitoring for non-viable particulates in the ISO …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  4. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 3

    OBSERVATION 3 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. a). Sporicidal agents are not used to disinfect the ISO 5 surfaces. b). No disinfectant effectiveness studies have been performed to determine if disinfection agents are effective in aseptic processing areas. Disinfectants used (b)(4) are (b)(4) on a (b)(4) basis and (b)(4) which is used …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  5. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 6

    OBSERVATION 6 The separate or defined areas necessary to prevent contamination or mix-ups are deficient. There are no separate facilities, for processing operations, to prevent contamination from the beta-Lactam injectable drug that you process - Ceftazidime syringe. This beta-Lactam powder, which is contained in glass vials, is processed in the same ISO 5 hood as are sterile injectable non beta-Lactam drugs. There is no assurance that a …

    Opens with FDA's citation wording for 21 CFR 211.42(c)Read the Form 483 →

  6. Specialty Compounding LLC.Inspection ended May 5, 2015 · FEI 3009815000 · Observation 2

    Your firm has not ensured that your facility is suitably designed with respect to the flow of personnel, in-process materials, and finished sterile drugs; the need for room segregation and process separation; and the impact from heating ventilation and air conditioning (HVAC), air pressurization, and unidirectional airflow, to prevent contamination and other hazards to sterile drugs. Specifically, A. The smoke studies performed by your vendor in …

    Contains “HVAC”Read the Form 483 →

  7. Custom Compounding CenterInspection ended Apr 9, 2015 · FEI 3002401385 · Observation 2

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, A. Your firm failed to adequately validate the following sterile and non-sterile drug production areas currently classified by our firm as an ISO7 in the dynamic state: Cleanroom (sterile production room, positive pressure), Cleanroom (chemotherapy room, negative pressure), Anti-room …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iii)Read the Form 483 →

  8. Custom Compounding CenterInspection ended Apr 9, 2015 · FEI 3002401385 · Observation 3

    The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient. Specifically, A. During a review of your firm's 2014 - 2015 Environmental Monitoring analysis, smoke pattern studies, for sterile and non-sterile drug production ISO5 Classified (Sterile [illegible] Model #[illegible]) your [illegible] to perform these studies in the [illegible] and Non Sterile [illegible] dynamic state. On 4/1/2015, …

    Opens with FDA's citation wording for 21 CFR 211.42(c)Read the Form 483 →

  9. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 5

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, a. There are no smoke studies conducted under dynamic conditions in the ISO 5 laminar flow hood where aseptic operations are performed to verify there is no obstruction or alteration of the HEPA-filtered air. b. There is no continuous monitoring of differential air pressure between the ISO 5 laminar flow …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  10. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 6

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, There is no monitoring of viable particles, non-viable particles, work surfaces or personnel in the ISO 5 laminar flow hood where aseptic operations are performed.

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  11. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 7

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions. Specifically, Sporicidal disinfectants are not used to clean/disinfect the ISO 5 laminar flow hood.

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  12. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 1

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically: a). Smoke studies were not performed under dynamic conditions to verify that operators, processing equipment or activities of the ISO 7 clean room do not alter or impede the unidirectionality of air from the HEPA filters to the ISO 5 laminar flow benches where products are aseptically processed. b). The wall …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  13. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm has never monitored viable air counts. b. Environmental monitoring for non-viable particulates in the ISO 5 zones is not performed under dynamic conditions. This was last performed on 10/18/13 …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  14. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 4

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a. Sterile wipes which are used to disinfect the ISO 5 hoods' sterile processing surfaces are composed of particle shedding material. b. The firm does not use sporicidal agents to disinfect the ISO 5 surfaces. c. In the disinfection of the chemotherapy ISO 5 hoods, non-sterile wipes are used …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  15. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 7

    The operations relating to the processing and packing of penicillin are not performed in facilities separate from those used for other drug products for human use. Specifically, your firm is processing Penicillin-type drugs, such as Nafcillin IVPB and Oxacillin IVPB, in the same cleanroom with your non-penicillin products. The absence of a structurally isolated area creates the potential that accidental breakage of vials of penicillin powders …

    Opens with FDA's citation wording for 21 CFR 211.42(d)Read the Form 483 →

  16. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 8

    The separate or defined areas necessary to prevent contamination or mix-ups are deficient. Specifically, there are no separate facilities, for processing operations, to prevent contamination from beta-Lactam non-penicillin drugs, such as Cefazolin IVPB, Ceftazidime IVPB, Meropenem IVPB, and others. These beta Lactam powders, which are contained in glass vials, are processed in the same clean room as sterile non-beta Lactam drugs. There is no …

    Opens with FDA's citation wording for 21 CFR 211.42(c)Read the Form 483 →

  17. Qingdao Kangyuan Pharmaceutical Co., LTDInspection ended Jan 25, 2013 · FEI 3006512854 · Observation 13

    A physical inspection of the water system revealed the following: (b)(4) in the water distribution line installed type valves were mounted (b)(4) valves were installed in such a way that may not allow for storage tank. These (b)(4) after the water (b)(4) complete drainage. All valves observed at the use water use points are the (b)(4) valve type. There was a water leak at the connection of the tubing to a pressure gauge after the (b)(4). No TOC …

    Contains “water leak*”Read the Form 483 →

  18. Hospira Inc.Inspection ended Oct 24, 2012 · FEI 1925262 · Observation 2

    … There were 2 incidents within the past 2 months of city water leaking from sprinkler heads located in your aseptic areas; these sprinkler heads and piping had been replaced by your contractor during a recent shutdown. • Incident PRID: 95301 occurred 17 Aug 2012 near lyophilizer [illegible] (room 335, 335B) during the unloading of [illegible] drug product. The root cause of the leak was attributed to the tapering of the threading between the …

    Contains “water leak*”Read the Form 483 →

  19. Mid-States Closeouts, Inc.Inspection ended Dec 21, 2009 · FEI 3007926870 · Observation 2

    … Damaged ceiling tiles and holes were observed through out the facility; some areas contain food products: Holes were observed in the ceiling tile in the northeast and southeast corners of the north gymnasium on 11/30/09. In the hallway between the north and south gymnasiums a ceiling tile was observed missing on 11/30/09. Ceiling tiles were observed as missing or moved from their location in the old lunch room on the first floor in the northern …

    Contains “ceiling tile*”Read the Form 483 →

  20. Genzyme CorporationInspection ended Oct 10, 2008 · FEI 1000305672 · Observation 6

    [illegible] studies executed August 2007 during the operational qualification of the HVAC system for fill suite FF2-16, did not demonstrate the following: Critical aseptic connections [illegible] Routine functions of aseptic core operators, for example: a. manually placing stoppers or reorienting stoppers using forceps for filled vials b. withdrawing unfilled vials from the filling line for weight checks c. redirecting filled vials [illegible] …

    Contains “HVAC”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about facilities and HVAC in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.