FDA has 2 inspections on file for Infusion Options, Inc. in Brooklyn, New York (FEI 3008231170), from 2014 to 2017. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER · Division of Pharmaceutical Quality Operations I). FDA has also posted a Form 483 dated Jul 8, 2019 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 7 citations from this inspection. They are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2014–2017
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
3 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
3 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be pyrogen-free is not laboratory tested to determine conformance to such requirements.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    4. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    5. FDCA 503B(a)(10)

      Drug product label, outsourcer facility

      The labels of your outsourcing facility’s drug products are deficient.

    Show 2 more citations
    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the of drug products is not appropriate for the duties they perform.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic equipment systems

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically: a). Smoke studies were not performed under dynamic conditions to verify that operators, processing equipment or activities of the ISO 7 clean room do not alter or impede the unidirectionality of air from the HEPA filters to the ISO 5 laminar flow benches where products are aseptically processed. b). The wall mounted room pressure monitors used to monitor differential air pressures of the [illegible] and surrounding areas are not monitored periodically during production. It is only done [illegible]. Also, alarms generated by these monitors are not reviewed. c). Entry for materials used in sterile processing to one of the firm's clean rooms (ISO 7) is directly from an unclassified area.

    2. Observation 2

      Inappropriate personnel clothing/gowning

      Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform. • Sterile drug products are aseptically manipulated by the cleanroom operators who were observed wearing non-sterile gowns, non-sterile glasses/goggles, non-sterile footwear, and non-sterile facial masks. The procedure operators use to put on sterile gloves used at the chemo ISO work area is performed in a way as to risk contamination, since non-sterile gloves are used to handle sterile gloves. • The operator's face and head are not fully covered and allows exposed facial skin and hair over the critical ISO 5 laminar flow areas. • Gowning apparel is composed of particle shedding material.

    Show observations 3 to 13
    1. Observation 3

      Insufficient environmental monitoring

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm has never monitored viable air counts. b. Environmental monitoring for non-viable particulates in the ISO 5 zones is not performed under dynamic conditions. This was last performed on 10/18/13 and 11/26/13. c. The work surfaces, inside the ISO 5 hoods, are not tested for microbial contamination at least daily during periods of production and at the end of operations. This monitoring is only performed [illegible]. It is done after disinfecting the work surfaces and during the processing of a batch. d. Operators' gloves are not tested for microbial contamination at least daily. Glove fingertips are only monitored [illegible].

    2. Observation 4

      Inadequate cleaning/disinfection procedures

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a. Sterile wipes which are used to disinfect the ISO 5 hoods' sterile processing surfaces are composed of particle shedding material. b. The firm does not use sporicidal agents to disinfect the ISO 5 surfaces. c. In the disinfection of the chemotherapy ISO 5 hoods, non-sterile wipes are used to remove cytotoxic drugs from the surfaces. This is done after the hoods are disinfected with sterile wipes and [illegible].

    3. Observation 5

      Inadequate media fill/process simulations

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. No media fills/process simulations have been performed under the most stressful or challenging conditions/worst case scenarios and according to a written protocol. In the absence of a media fill record and having not defined the frequency of interventions, type of interventions, the target amounts of units to fill, the minimum duration of filling simulations, amount of employees inside the room for a given period of time, there is a lack of a demonstration that you have fulfilled the purpose of your media fill process. The rationale chosen for the conditions and activities simulated during the media fill are neither written nor defined. Additionally, testing conducted in lieu of media fills/process simulations to ensure that parenteral solutions are sterile, is not performed per the firm's procedure titled "Quality Control of Parenteral Solutions". a. Product or preparation samples are not used. b. The pharmacist does not check for turbidity daily. c. All (instead of 14 days) incubation period is used without justification. (b)(4) d. The incubation temperature used differs from the test kit manufacturer's recommendation of 22.5 +/- 2.5 degrees C.

    4. Observation 6

      Lack of sterility and endotoxin testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, given the observed inadequate environmental controls, testing is deficient in that: a. Your firm has not conducted sterility testing for any batches (totaling [illegible] units) of outsourced sterile drugs since the registration date of 01/24/14. b. Endotoxin testing has not been performed for any outsourced sterile drug products produced.

    5. Observation 7

      Penicillin processed with others

      The operations relating to the processing and packing of penicillin are not performed in facilities separate from those used for other drug products for human use. Specifically, your firm is processing Penicillin-type drugs, such as Nafcillin IVPB and Oxacillin IVPB, in the same cleanroom with your non-penicillin products. The absence of a structurally isolated area creates the potential that accidental breakage of vials of penicillin powders could contaminate your other sterile drug products.

    6. Observation 8

      No separate areas for beta-lactams

      The separate or defined areas necessary to prevent contamination or mix-ups are deficient. Specifically, there are no separate facilities, for processing operations, to prevent contamination from beta-Lactam non-penicillin drugs, such as Cefazolin IVPB, Ceftazidime IVPB, Meropenem IVPB, and others. These beta Lactam powders, which are contained in glass vials, are processed in the same clean room as sterile non-beta Lactam drugs. There is no assurance that a potential breakage of the glass vial and consequent powder spill would not contaminate other sterile drug products.

    7. Observation 9

      No investigation of non-sterile lot

      Any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications shall be thoroughly investigated, whether or not the batch has already been distributed. Lot number 0806121600 of Heparin 5000 Units/L NS was tested on 08/14/12 and found to be "Not Sterile" at Day 0. There was no investigation conducted to determine the cause and impact of this result.

    8. Observation 10

      Containers/closures not reviewed for sterility

      Containers and closures are not reviewed for conformance with all appropriate written procedures. Specifically, Your firm does not receive or review certificates of analysis showing sterility for the sterile containers, such as IV bags, used for sterile drug products. Purchased sterile equipment, such as transfer tubing, are accepted into inventory and used for sterile drug processing without reviewing the manufacturer's certificate of analysis to assure sterility.

    9. Observation 11

      No visual checks against contrast

      For each batch of drug product, there shall be appropriate laboratory determination of satisfactory conformance to final specifications for the drug product. Specifically, visual checks of sterile drugs for clarity/discoloration or particulates/contaminants are not performed against a contrasting background.

    10. Observation 12

      Labeling procedures not established/written

      There shall be written procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products; such written procedures shall be followed. These procedures shall incorporate the following features: Identification of the drug product with a lot or control number that permits determination of the history of the manufacture and control of the batch.

    11. Observation 13

      Labels missing required information

      The labels of your firm's drug products do not include information required by section 503B(a)(10) of the Act. a. The following drug product label does not contain the following: the statements "This is a compounded drug," "Not for Resale," and "Office Use Only;" the address and phone number of the applicable outsourcing facility; inactive ingredient; and information to facilitate adverse event reporting (www.fda.gov/medwatch and 1-800 FDA-1088): Vancomycin Oral Solution 125mg in 5mL syringe [not sterile]. b. The following labels do not contain the dosage form; route of administration and the statement "Office Use Only": Dexamethasone 10 mg in 50mL of 0.9% NaCl bag Dexamethasone 20 mg in 50 mL of 0.9% NaCl bag Diphenhydramine 25mg in 50 mL of 0.9% NaCl bag Diphenhydramine 50mg in 50mL of 0.9% NaCl bag Heparin 1000 units in 500mL 0.9% Sodium Chloride bag Heparin 2000 units in 1000 mL 0.9% Sodium Chloride bag Heparin 2500 units in 500 mL 0.9% Sodium Chloride bag Heparin 5000 units in 1000mL 0.9% Sodium Chloride bag Oxytocin 10 Units added to 1000 mL Lactated Ringers Injectable Bag Oxytocin 20 Units added to 1000 mL Lactated Ringers Injectable Bag Oxytocin 60 Units added to 1000 mL Lactated Ringers Injectable Bag Vancomycin 1 gram added to 250 mL 0.9% Sodium Chloride Injectable Bag.

Regulations FDA cited here

The 6 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3008231170 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3008231170. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.