Infusion Options, Inc. Form 483, April 2014
FDA issued this Form 483 to Infusion Options, Inc. in Brooklyn, New York (FEI 3008231170) at the end of a drug inspection that ended April 23, 2014. It lists 13 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Apr 23, 2014
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jan 17, 2024
- 3,556 days after the inspection
The 13 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate aseptic equipment systems
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically: a). Smoke studies were not performed under dynamic conditions to verify that operators, processing equipment or activities of the ISO 7 clean room do not alter or impede the unidirectionality of air from the HEPA filters to the ISO 5 laminar flow benches where products are aseptically processed. b). The wall mounted room pressure monitors used to monitor differential air pressures of the [illegible] and surrounding areas are not monitored periodically during production. It is only done [illegible]. Also, alarms generated by these monitors are not reviewed. c). Entry for materials used in sterile processing to one of the firm's clean rooms (ISO 7) is directly from an unclassified area.
- 2
Inappropriate personnel clothing/gowning
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform. • Sterile drug products are aseptically manipulated by the cleanroom operators who were observed wearing non-sterile gowns, non-sterile glasses/goggles, non-sterile footwear, and non-sterile facial masks. The procedure operators use to put on sterile gloves used at the chemo ISO work area is performed in a way as to risk contamination, since non-sterile gloves are used to handle sterile gloves. • The operator's face and head are not fully covered and allows exposed facial skin and hair over the critical ISO 5 laminar flow areas. • Gowning apparel is composed of particle shedding material.
- 3
Insufficient environmental monitoring
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm has never monitored viable air counts. b. Environmental monitoring for non-viable particulates in the ISO 5 zones is not performed under dynamic conditions. This was last performed on 10/18/13 and 11/26/13. c. The work surfaces, inside the ISO 5 hoods, are not tested for microbial contamination at least daily during periods of production and at the end of operations. This monitoring is only performed [illegible]. It is done after disinfecting the work surfaces and during the processing of a batch. d. Operators' gloves are not tested for microbial contamination at least daily. Glove fingertips are only monitored [illegible].
- 4
Inadequate cleaning/disinfection procedures
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a. Sterile wipes which are used to disinfect the ISO 5 hoods' sterile processing surfaces are composed of particle shedding material. b. The firm does not use sporicidal agents to disinfect the ISO 5 surfaces. c. In the disinfection of the chemotherapy ISO 5 hoods, non-sterile wipes are used to remove cytotoxic drugs from the surfaces. This is done after the hoods are disinfected with sterile wipes and [illegible].
- 5
Inadequate media fill/process simulations
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. No media fills/process simulations have been performed under the most stressful or challenging conditions/worst case scenarios and according to a written protocol. In the absence of a media fill record and having not defined the frequency of interventions, type of interventions, the target amounts of units to fill, the minimum duration of filling simulations, amount of employees inside the room for a given period of time, there is a lack of a demonstration that you have fulfilled the purpose of your media fill process. The rationale chosen for the conditions and activities simulated during the media fill are neither written nor defined. Additionally, testing conducted in lieu of media fills/process simulations to ensure that parenteral solutions are sterile, is not performed per the firm's procedure titled "Quality Control of Parenteral Solutions". a. Product or preparation samples are not used. b. The pharmacist does not check for turbidity daily. c. All (instead of 14 days) incubation period is used without justification. (b)(4) d. The incubation temperature used differs from the test kit manufacturer's recommendation of 22.5 +/- 2.5 degrees C.
- 6
Lack of sterility and endotoxin testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, given the observed inadequate environmental controls, testing is deficient in that: a. Your firm has not conducted sterility testing for any batches (totaling [illegible] units) of outsourced sterile drugs since the registration date of 01/24/14. b. Endotoxin testing has not been performed for any outsourced sterile drug products produced.
- 7
Penicillin processed with others
The operations relating to the processing and packing of penicillin are not performed in facilities separate from those used for other drug products for human use. Specifically, your firm is processing Penicillin-type drugs, such as Nafcillin IVPB and Oxacillin IVPB, in the same cleanroom with your non-penicillin products. The absence of a structurally isolated area creates the potential that accidental breakage of vials of penicillin powders could contaminate your other sterile drug products.
- 8
No separate areas for beta-lactams
The separate or defined areas necessary to prevent contamination or mix-ups are deficient. Specifically, there are no separate facilities, for processing operations, to prevent contamination from beta-Lactam non-penicillin drugs, such as Cefazolin IVPB, Ceftazidime IVPB, Meropenem IVPB, and others. These beta Lactam powders, which are contained in glass vials, are processed in the same clean room as sterile non-beta Lactam drugs. There is no assurance that a potential breakage of the glass vial and consequent powder spill would not contaminate other sterile drug products.
- 9
No investigation of non-sterile lot
Any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications shall be thoroughly investigated, whether or not the batch has already been distributed. Lot number 0806121600 of Heparin 5000 Units/L NS was tested on 08/14/12 and found to be "Not Sterile" at Day 0. There was no investigation conducted to determine the cause and impact of this result.
- 10
Containers/closures not reviewed for sterility
Containers and closures are not reviewed for conformance with all appropriate written procedures. Specifically, Your firm does not receive or review certificates of analysis showing sterility for the sterile containers, such as IV bags, used for sterile drug products. Purchased sterile equipment, such as transfer tubing, are accepted into inventory and used for sterile drug processing without reviewing the manufacturer's certificate of analysis to assure sterility.
- 11
No visual checks against contrast
For each batch of drug product, there shall be appropriate laboratory determination of satisfactory conformance to final specifications for the drug product. Specifically, visual checks of sterile drugs for clarity/discoloration or particulates/contaminants are not performed against a contrasting background.
- 12
Labeling procedures not established/written
There shall be written procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products; such written procedures shall be followed. These procedures shall incorporate the following features: Identification of the drug product with a lot or control number that permits determination of the history of the manufacture and control of the batch.
- 13
Labels missing required information
The labels of your firm's drug products do not include information required by section 503B(a)(10) of the Act. a. The following drug product label does not contain the following: the statements "This is a compounded drug," "Not for Resale," and "Office Use Only;" the address and phone number of the applicable outsourcing facility; inactive ingredient; and information to facilitate adverse event reporting (www.fda.gov/medwatch and 1-800 FDA-1088): Vancomycin Oral Solution 125mg in 5mL syringe [not sterile]. b. The following labels do not contain the dosage form; route of administration and the statement "Office Use Only": Dexamethasone 10 mg in 50mL of 0.9% NaCl bag Dexamethasone 20 mg in 50 mL of 0.9% NaCl bag Diphenhydramine 25mg in 50 mL of 0.9% NaCl bag Diphenhydramine 50mg in 50mL of 0.9% NaCl bag Heparin 1000 units in 500mL 0.9% Sodium Chloride bag Heparin 2000 units in 1000 mL 0.9% Sodium Chloride bag Heparin 2500 units in 500 mL 0.9% Sodium Chloride bag Heparin 5000 units in 1000mL 0.9% Sodium Chloride bag Oxytocin 10 Units added to 1000 mL Lactated Ringers Injectable Bag Oxytocin 20 Units added to 1000 mL Lactated Ringers Injectable Bag Oxytocin 60 Units added to 1000 mL Lactated Ringers Injectable Bag Vancomycin 1 gram added to 250 mL 0.9% Sodium Chloride Injectable Bag.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterMar 21, 2016CDER · 698 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3008231170, newest first.
- Amended Form 483, July 2019FDA record date Jul 8, 2019 · Posted Sep 30, 2019
- Form 483, October 2018FDA record date Oct 24, 2018 · Posted Jan 17, 2024
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.