Qingdao Kangyuan Pharmaceutical Co., LTD Form 483, January 2013

FDA issued this Form 483 to Qingdao Kangyuan Pharmaceutical Co., LTD in Qingdao, China (FEI 3006512854) at the end of a drug inspection that ended January 25, 2013. It lists 16 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jan 25, 2013
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 13, 2026
5,040 days after the inspection
Facility
FEI 3006512854
Qingdao, China

The 16 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Labeling quantities and USP vs ChP testing

    From 12/10 to 7/12, quantities of (b)(4) finished batches of labeling for use in (b)(4) but no lot number of (b)(4) used were recorded. [illegible] bearing a (b)(4) have been shipped to USA. The finished product shipped to the USA was tested based on the Chinese Pharmacopeia method. On December 27-31, 2012, a study was performed comparing only the potency method listed [in] the Chinese Pharmacopeia with the USP (lot) (b)(4)

  2. 2

    No approved stability protocol and sample control

    There is no written and approved stability study protocol. The three PV batches (b)(4) were reportedly placed on stability studies. However, the samples for these batches were initially stored in a refrigerator. The samples were moved from the refrigerator to two other stability storage study units, but there is no written explanation as to how, when, and why the samples were managed when moved out each of the stability study storage units.

  3. 3

    Missing impurity profile protocol and data

    There was no study protocol to for developing an impurity profile on the product nor there was an impurity profile on (b)(4) produced at the current manufacturing site for review.

  4. 4

    No forced degradation and solvent testing

    No forced degradation studies have been performed or (b)(4) in the finished product. This (b)(4) is used in the process but neither the intermediate or the finished product is tested for this solvent.

  5. 5

    Unqualified residual solvent ChP method equivalence

    The contract laboratory performs the residual solvent test for detecting (b)(4). This test is reportedly performed in accordance with the Chinese Pharmacopeia method. There is no information to determine whether this method is equivalent to the USP <467> method. Also, there is no information to determine whether the Chinese Pharmacopeia method had been qualified by performing at least linearity and specificity with equipment used for testing. Moreover, (b)(4)

  6. 6

    Incoming solvent not tested for purity

    The incoming solvent (b)(4) used in the process is not tested for purity/potency.

  7. 7

    Crude suppliers untested and poor traceability

    The Crude product used to produce the finished product is produced by (b)(4) different suppliers. Reportedly, these suppliers do not have the capability of testing the crude product and the product is received untested. QKP tests the crude product. However, review of test records for the potency test performed found no data to allow traceability of lot numbers and expiration dates on reagents and solutions (i.e., standard solution, water, and (b)(4)) used when the test is performed; for example, Crude supplier's lot # (b)(4) tested on 3/20/12.

  8. 8

    Different apparatus outputs without investigation

    (b)(4) (b)(4) step, (b)(4) generate noticeably (b)(4) different despite apparatuses being essentially the same. No investigation or experiment has (b)(4) (b)(4) been done to determine why the (b)(4) from these apparatuses look different.

  9. 9

    Unqualified process apparatus and undocumented lot

    The (b)(4) step requires the use of (b)(4) is fixed at (b)(4) has not been (b)(4) apparatus). It was reported that (b)(4) but the (b)(4) (b)(4) qualified to assure that the (b)(4) its (b)(4) is accurate, precise, linear, and robust. Also, the lot number of the (b)(4) (b)(4) use during the manufacturing is not documented; for example during the Processing of process Validation batches (b)(4)

  10. 10

    BPR missing process step duration

    The BPR does not document the duration of the (b)(4) step of the (b)(4) during production; for example, at (b)(4) (b)(4) the (b)(4) stage the (b)(4) (b)(4) is (b)(4)

  11. 11

    Undocumented BPR measurement procedure

    An entry in page (b)(4) of the BPR for the (b)(4) processing step documents that (b)(4) of the (b)(4) (b)(4) were collected and measured. However, while questioning this BPR entry, it was reported (b)(4) (b)(4) that the operator measures the amount of The (b)(4) measurement is done The actual steps as to how the operator came up with the value, documented in the BPR, are not documented in the (b)(4) BPR or explained in an operating instruction procedure.

  12. 12

    Returned product not checked by QA

    SOP 10-103 requires QA to check and sample products that are returned to the site. However, there is no data to show that QA checked the amount of batch (b)(4) returned to the firm on 2/28/11 and 3/16/11, respectively. It was reported that this product was returned from the USA due to the product cost being too high. The product was accepted by warehouse personnel and returned to product release inventory.

  13. 13

    Water system valves, leak and no TOC

    A physical inspection of the water system revealed the following: (b)(4) in the water distribution line installed type valves were mounted (b)(4) valves were installed in such a way that may not allow for storage tank. These (b)(4) after the water (b)(4) complete drainage. All valves observed at the use water use points are the (b)(4) valve type. There was a water leak at the connection of the tubing to a pressure gauge after the (b)(4). No TOC test is performed.

  14. 14

    Unstable balance table and improper calibration

    SOP 09-301 requires analytical balances to be placed on a vibration proof surface. However, inspection of the table used to hold Mettler Toledo analytical balance #JY-TP-12-01 revealed that the table vibrated to the touch. Also, one of the legs of the table appeared to be shorter than the other 3 legs and was supported by what appeared to be a folded carton. Also, the [illegible] check of the balance was performed using a (b)(4) mass grams weight when in fact the sample weight used in testing is in milligrams.

  15. 15

    Unidentified uncalibrated weighing scale

    There was no identification, calibration record, or usage log on a scale found in the raw material weighing and dispensing room. Reportedly, this scale is used to weigh (b)(4) used in the product formulation and recorded in the BPR.

  16. 16

    Undated loose batch records in desk

    There were several undated loose pages of partially completed batch production records for processing stages (b)(4) steps) in a drawer of a desk in the office used by production operators and management.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3006512854, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.