Qingdao Kangyuan Pharmaceutical Co., LTD Form 483, April 2016
FDA issued this Form 483 to Qingdao Kangyuan Pharmaceutical Co., LTD in Qingdao, China (FEI 3006512854) at the end of a drug inspection that ended April 22, 2016. It lists 11 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Apr 22, 2016
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 13, 2026
- 3,857 days after the inspection
The 11 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Impurity profile study incomplete, no response
During the previous inspection on 1/25/2013, it was found that no study protocol had been generated for impurity profile characterization of (b)(4) It had been stated in the firm's response of 3/1/2013 that a draft protocol would be submitted to the FDA in 1-2 months. During the current inspection, although your firm presented some draft data (not in English), but your firm did not produce a conclusive impurity summary results in English. Further, your firm stated that as of date, no response has been submitted to the FDA as the impurity studies are still in-progress.
- 2
Differing test results, methods not qualified
During the previous inspection on 1/25/2013, it was found that the results from the (b)(4) (b)(4) (b)(4) were noticeably different. According to your firm's response, these different (b)(4) are within range and do not impact the product quality. According to our conversation, you have added another (b)(4) but none of these have been qualified to assure that its (b)(4) is accurate, precise, linear, and robust.
- 3
HVAC powered off without qualification data
During our walkthrough of the Building (b)(4) which is used for (b)(4) API production, your firm explained that the HVAC, ID #SC-KTJ-12-01, for clean rooms class D is powered off during non-operation. It was further explained that the HVAC power is turned on for (b)(4) during non-operation. Since the HVAC system is re-qualified (b)(4) and was last re-qualified on 7/12/2015, no data was presented as to its qualification status when the system is powered off and only powered on for (b)(4) during non-operation.
- 4
Replacement frequency not in maintenance schedule
Since the qualification of the (b)(4) (b)(4) The firm explained that the (b)(4) used during (b)(4) step is replaced according to the manufacturer (b)(4) none of the (b)(4) replacement frequencies are specified in the maintenance schedule and it is unclear how the replacement will occur in the batch record instructions.
- 5
Water system monitoring lacking
The (b)(4) of the (b)(4) water system is not monitored and no (b)(4) are installed throughout water distribution tank and the loop system to the (b)(4) building workshop. There is no (b)(4) indication of the (b)(4) system.
- 6
Missing bulk hold-time data
The firm has conducted bulk hold-time studies for the (b)(4) crude, (b)(4) operations. The firm, however, did not produce bulk hold-time data for the (b)(4) stages of the (b)(4) production.
- 7
Scale calibration does not cover range
The scale, ID # SC-DZC-17-06, which is used in the (b)(4) room, is (b)(4) calibrated using a (b)(4) standard weight. However the scale weighing range is between (b)(4) to (b)(4) In addition the vendor calibration certificate dated (b)(4) did not indicate that the scale had been calibrated within the scale weighing range. The scale (b)(4) calibration does not cover the stated scale weighing range.
- 8
Balance and weight on warehouse floor
On 4/18/16, we observed an electrical balance, ID # SC-DZC-17-04, and a container housing a (b)(4) reference weight, ID # SC-DZC-17-04, sitting on the floor of the (b)(4) Warehouse (b)(4) which may be subject to contamination and instability. The balance is used to check the weight of incoming (b)(4) raw materials after receipt by the warehouse.
- 9
Weighing records incomplete, left on floor
On 4/18/16, we observed an attachment form, titled "Balance using records 03-103-A1 02", which was used to record the weight of (b)(4) materials, (b)(4) Crude, on 4/2/16. The actual weight of each material is not recorded on the form. This form was found sitting on the floor of the (b)(4) Warehouse (b)(4) next to the electrical balance, ID # SC-DZC-17-04, and a container housing a (b)(4) reference weight, ID #SC-DZC-17-04.
- 10
Calibration SOP lacks placement instructions
The written procedure, Gauge and Calibration Management, SOP 03-103, version 02, effective date 7/20/15, did not include adequate instructions regarding where a balance should be placed for weighing and measuring operations. This procedure only states to place the instrument in a clean and dry environment. The procedure also does not have instructions regarding re-calibration of a balance after it is moved.
- 11
Exterior stations lacking controls
On 4/20/16, during the walkthrough of the building (b)(4) Workshop, we observed (b)(4) stations situated on the exterior of the building which contained no (b)(4)
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3006512854, newest first.
- Form 483, August 2024Inspection ended Aug 16, 2024 · Posted Nov 13, 2026VAI
- Form 483, January 2013Inspection ended Jan 25, 2013 · Posted Nov 13, 2026VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.