Qingdao Kangyuan Pharmaceutical Co., LTD Form 483, August 2024
FDA issued this Form 483 to Qingdao Kangyuan Pharmaceutical Co., LTD in Qingdao, China (FEI 3006512854) at the end of a drug inspection that ended August 16, 2024. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Aug 16, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 13, 2026
- 819 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate water system monitoring and testing
Laboratory controls do not include scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that raw materials conform to established standards of quality and/or purity. Specifically, Your firm failed to monitor the water system, so it consistently produces pharmaceutical grade water that, at a minimum, meets the USP monograph for (b)(4) water and appropriate microbial limits. Your firm's current test methods used to detect objectionable microbiological contamination in water used to manufacture APIs do not include microbial testing methods to detect the presence of objectionable organisms such as Burkholderia cepacia complex, Escherichia coli or Staphylococcus aureus. Furthermore, your firm water sampling Standard Operating Procedure titled "Water for Production Use Operational Procedures STP", Version No: 10, Effective Date: 08/02/2024, SOP Number: 09-224 specifies in section 5.1.4.2.2.4 that a (b)(4) (b)(4) will be performed [illegible] the QA personnel [illegible] collecting the water sample. Your firm Standard Operating Procedure titled [illegible] Water System Operating, Maintenance and Cleaning", Version No: 11, Effective Date: 08/02/2024, SOP Number: 02-104 used to instruct (b)(4) operators on the use of (b)(4) water in the manufacturing areas does not establish a [illegible]. Your sampling methods are not representative of the actual water use practices at your firm production areas. (b)(4) water is used as a raw material in the manufacturing process of your API.
- 2
Master batch record lacks time limits
The master batch production record lacks an established time limit and detailed production instructions to ensure the quality of intermediates and APIs are met for individual processing steps and/or total process. Specifically, Your firm failed to establish and document a specific time limit in the Batch Manufacturing Record (BMR) for the (b)(4) (b)(4) (b)(4) step in the crude manufacturing process of (b)(4). Additionally, there is (b)(4) occurring during the (b)(4) process that is not being recorded in the manufacturing record. Your firm operates with (b)(4) (b)(4) different capacities. Each (b)(4) has different capabilities, causing the (b)(4) to vary from batch to batch. Similarly, your firm did not record the duration of the (b)(4) process following the (b)(4) steps. The current Batch Manufacturing Record (BMR) logs the total time taken to complete all loads but fails to document the time for each individual load. Although your firm has set a minimum (b)(4) time of (b)(4) load, it did not document whether this time requirement was met for each load.
- 3
Unverified analytical method suitability
Failure to validate and verify the suitability of analytical methods. Specifically, (b)(4) Your firm is using the Chinese Pharmacopeia for identity testing of a raw material used in the production of (b)(4). [illegible] Chinese Pharmacopeia identity test method for (b)(4) is equivalent to, or better than, the U.S. Pharmacopeia (USP) identity test method for the same substance.
- 4
Equipment not maintained in good repair
Equipment used in the manufacture of intermediates and API's should be maintained in a good state of repair to prevent contamination that would alter the safety, identity, strength, quality and purity of the drug product. Specifically, During the inspectional walkthrough, on 08/12/2024 it was observed that your firm failed to maintain equipment used in the manufacturing of API and intermediates in a good state of repair. Your (b)(4) located (b)(4) (b)(4) had material [illegible] maintenance check was performed on 08/01/2024, but this deficiency was not addressed. (b)(4) located in building (b)(4) used in the manufacture of (b)(4) were marked as cleaned, but had what appeared to be rust flakes at the bottom of the (b)(4). Upon further inspection, it was determined that the rust flakes originated from the (b)(4) used in the manufacture of (b)(4) in building (b)(4) flaking into the (b)(4) and (b)(4) Furthermore, (b)(4) (b)(4) located on top each (b)(4).
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3006512854, newest first.
- Form 483, April 2016Inspection ended Apr 22, 2016 · Posted Nov 13, 2026VAI
- Form 483, January 2013Inspection ended Jan 25, 2013 · Posted Nov 13, 2026VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.