Skip to content

Qingdao Kangyuan Pharmaceutical Co. Ltd.

Yinghai Industrial Park, Jiaozhou City, Qingdao, China

FEI 3006512854DUNS 529604063

FDA has 3 inspections on file for Qingdao Kangyuan Pharmaceutical Co. Ltd. in Qingdao, China (FEI 3006512854), from 2013 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant is Qingdao Kangyuan Pharmaceutical Co., Ltd (D-U-N-S 529604063).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2013–2024
0 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
1 request, latest Jun 17, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate water system monitoring and testing

      Laboratory controls do not include scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that raw materials conform to established standards of quality and/or purity. Specifically, Your firm failed to monitor the water system, so it consistently produces pharmaceutical grade water that, at a minimum, meets the USP monograph for (b)(4) water and appropriate microbial limits. Your firm's current test methods used to detect objectionable microbiological contamination in water used to manufacture APIs do not include microbial testing methods to detect the presence of objectionable organisms such as Burkholderia cepacia complex, Escherichia coli or Staphylococcus aureus. Furthermore, your firm water sampling Standard Operating Procedure titled "Water for Production Use Operational Procedures STP", Version No: 10, Effective Date: 08/02/2024, SOP Number: 09-224 specifies in section 5.1.4.2.2.4 that a (b)(4) (b)(4) will be performed [illegible] the QA personnel [illegible] collecting the water sample. Your firm Standard Operating Procedure titled [illegible] Water System Operating, Maintenance and Cleaning", Version No: 11, Effective Date: 08/02/2024, SOP Number: 02-104 used to instruct (b)(4) operators on the use of (b)(4) water in the manufacturing areas does not establish a [illegible]. Your sampling methods are not representative of the actual water use practices at your firm production areas. (b)(4) water is used as a raw material in the manufacturing process of your API.

    2. Observation 2

      Master batch record lacks time limits

      The master batch production record lacks an established time limit and detailed production instructions to ensure the quality of intermediates and APIs are met for individual processing steps and/or total process. Specifically, Your firm failed to establish and document a specific time limit in the Batch Manufacturing Record (BMR) for the (b)(4) (b)(4) (b)(4) step in the crude manufacturing process of (b)(4). Additionally, there is (b)(4) occurring during the (b)(4) process that is not being recorded in the manufacturing record. Your firm operates with (b)(4) (b)(4) different capacities. Each (b)(4) has different capabilities, causing the (b)(4) to vary from batch to batch. Similarly, your firm did not record the duration of the (b)(4) process following the (b)(4) steps. The current Batch Manufacturing Record (BMR) logs the total time taken to complete all loads but fails to document the time for each individual load. Although your firm has set a minimum (b)(4) time of (b)(4) load, it did not document whether this time requirement was met for each load.

    Show observations 3 to 4
    1. Observation 3

      Unverified analytical method suitability

      Failure to validate and verify the suitability of analytical methods. Specifically, (b)(4) Your firm is using the Chinese Pharmacopeia for identity testing of a raw material used in the production of (b)(4). [illegible] Chinese Pharmacopeia identity test method for (b)(4) is equivalent to, or better than, the U.S. Pharmacopeia (USP) identity test method for the same substance.

    2. Observation 4

      Equipment not maintained in good repair

      Equipment used in the manufacture of intermediates and API's should be maintained in a good state of repair to prevent contamination that would alter the safety, identity, strength, quality and purity of the drug product. Specifically, During the inspectional walkthrough, on 08/12/2024 it was observed that your firm failed to maintain equipment used in the manufacturing of API and intermediates in a good state of repair. Your (b)(4) located (b)(4) (b)(4) had material [illegible] maintenance check was performed on 08/01/2024, but this deficiency was not addressed. (b)(4) located in building (b)(4) used in the manufacture of (b)(4) were marked as cleaned, but had what appeared to be rust flakes at the bottom of the (b)(4). Upon further inspection, it was determined that the rust flakes originated from the (b)(4) used in the manufacture of (b)(4) in building (b)(4) flaking into the (b)(4) and (b)(4) Furthermore, (b)(4) (b)(4) located on top each (b)(4).

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Impurity profile study incomplete, no response

      During the previous inspection on 1/25/2013, it was found that no study protocol had been generated for impurity profile characterization of (b)(4) It had been stated in the firm's response of 3/1/2013 that a draft protocol would be submitted to the FDA in 1-2 months. During the current inspection, although your firm presented some draft data (not in English), but your firm did not produce a conclusive impurity summary results in English. Further, your firm stated that as of date, no response has been submitted to the FDA as the impurity studies are still in-progress.

    2. Observation 2

      Differing test results, methods not qualified

      During the previous inspection on 1/25/2013, it was found that the results from the (b)(4) (b)(4) (b)(4) were noticeably different. According to your firm's response, these different (b)(4) are within range and do not impact the product quality. According to our conversation, you have added another (b)(4) but none of these have been qualified to assure that its (b)(4) is accurate, precise, linear, and robust.

    Show observations 3 to 11
    1. Observation 3

      HVAC powered off without qualification data

      During our walkthrough of the Building (b)(4) which is used for (b)(4) API production, your firm explained that the HVAC, ID #SC-KTJ-12-01, for clean rooms class D is powered off during non-operation. It was further explained that the HVAC power is turned on for (b)(4) during non-operation. Since the HVAC system is re-qualified (b)(4) and was last re-qualified on 7/12/2015, no data was presented as to its qualification status when the system is powered off and only powered on for (b)(4) during non-operation.

    2. Observation 4

      Replacement frequency not in maintenance schedule

      Since the qualification of the (b)(4) (b)(4) The firm explained that the (b)(4) used during (b)(4) step is replaced according to the manufacturer (b)(4) none of the (b)(4) replacement frequencies are specified in the maintenance schedule and it is unclear how the replacement will occur in the batch record instructions.

    3. Observation 5

      Water system monitoring lacking

      The (b)(4) of the (b)(4) water system is not monitored and no (b)(4) are installed throughout water distribution tank and the loop system to the (b)(4) building workshop. There is no (b)(4) indication of the (b)(4) system.

    4. Observation 6

      Missing bulk hold-time data

      The firm has conducted bulk hold-time studies for the (b)(4) crude, (b)(4) operations. The firm, however, did not produce bulk hold-time data for the (b)(4) stages of the (b)(4) production.

    5. Observation 7

      Scale calibration does not cover range

      The scale, ID # SC-DZC-17-06, which is used in the (b)(4) room, is (b)(4) calibrated using a (b)(4) standard weight. However the scale weighing range is between (b)(4) to (b)(4) In addition the vendor calibration certificate dated (b)(4) did not indicate that the scale had been calibrated within the scale weighing range. The scale (b)(4) calibration does not cover the stated scale weighing range.

    6. Observation 8

      Balance and weight on warehouse floor

      On 4/18/16, we observed an electrical balance, ID # SC-DZC-17-04, and a container housing a (b)(4) reference weight, ID # SC-DZC-17-04, sitting on the floor of the (b)(4) Warehouse (b)(4) which may be subject to contamination and instability. The balance is used to check the weight of incoming (b)(4) raw materials after receipt by the warehouse.

    7. Observation 9

      Weighing records incomplete, left on floor

      On 4/18/16, we observed an attachment form, titled "Balance using records 03-103-A1 02", which was used to record the weight of (b)(4) materials, (b)(4) Crude, on 4/2/16. The actual weight of each material is not recorded on the form. This form was found sitting on the floor of the (b)(4) Warehouse (b)(4) next to the electrical balance, ID # SC-DZC-17-04, and a container housing a (b)(4) reference weight, ID #SC-DZC-17-04.

    8. Observation 10

      Calibration SOP lacks placement instructions

      The written procedure, Gauge and Calibration Management, SOP 03-103, version 02, effective date 7/20/15, did not include adequate instructions regarding where a balance should be placed for weighing and measuring operations. This procedure only states to place the instrument in a clean and dry environment. The procedure also does not have instructions regarding re-calibration of a balance after it is moved.

    9. Observation 11

      Exterior stations lacking controls

      On 4/20/16, during the walkthrough of the building (b)(4) Workshop, we observed (b)(4) stations situated on the exterior of the building which contained no (b)(4)

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 16 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Labeling quantities and USP vs ChP testing

      From 12/10 to 7/12, quantities of (b)(4) finished batches of labeling for use in (b)(4) but no lot number of (b)(4) used were recorded. [illegible] bearing a (b)(4) have been shipped to USA. The finished product shipped to the USA was tested based on the Chinese Pharmacopeia method. On December 27-31, 2012, a study was performed comparing only the potency method listed [in] the Chinese Pharmacopeia with the USP (lot) (b)(4)

    2. Observation 2

      No approved stability protocol and sample control

      There is no written and approved stability study protocol. The three PV batches (b)(4) were reportedly placed on stability studies. However, the samples for these batches were initially stored in a refrigerator. The samples were moved from the refrigerator to two other stability storage study units, but there is no written explanation as to how, when, and why the samples were managed when moved out each of the stability study storage units.

    Show observations 3 to 16
    1. Observation 3

      Missing impurity profile protocol and data

      There was no study protocol to for developing an impurity profile on the product nor there was an impurity profile on (b)(4) produced at the current manufacturing site for review.

    2. Observation 4

      No forced degradation and solvent testing

      No forced degradation studies have been performed or (b)(4) in the finished product. This (b)(4) is used in the process but neither the intermediate or the finished product is tested for this solvent.

    3. Observation 5

      Unqualified residual solvent ChP method equivalence

      The contract laboratory performs the residual solvent test for detecting (b)(4). This test is reportedly performed in accordance with the Chinese Pharmacopeia method. There is no information to determine whether this method is equivalent to the USP <467> method. Also, there is no information to determine whether the Chinese Pharmacopeia method had been qualified by performing at least linearity and specificity with equipment used for testing. Moreover, (b)(4)

    4. Observation 6

      Incoming solvent not tested for purity

      The incoming solvent (b)(4) used in the process is not tested for purity/potency.

    5. Observation 7

      Crude suppliers untested and poor traceability

      The Crude product used to produce the finished product is produced by (b)(4) different suppliers. Reportedly, these suppliers do not have the capability of testing the crude product and the product is received untested. QKP tests the crude product. However, review of test records for the potency test performed found no data to allow traceability of lot numbers and expiration dates on reagents and solutions (i.e., standard solution, water, and (b)(4)) used when the test is performed; for example, Crude supplier's lot # (b)(4) tested on 3/20/12.

    6. Observation 8

      Different apparatus outputs without investigation

      (b)(4) (b)(4) step, (b)(4) generate noticeably (b)(4) different despite apparatuses being essentially the same. No investigation or experiment has (b)(4) (b)(4) been done to determine why the (b)(4) from these apparatuses look different.

    7. Observation 9

      Unqualified process apparatus and undocumented lot

      The (b)(4) step requires the use of (b)(4) is fixed at (b)(4) has not been (b)(4) apparatus). It was reported that (b)(4) but the (b)(4) (b)(4) qualified to assure that the (b)(4) its (b)(4) is accurate, precise, linear, and robust. Also, the lot number of the (b)(4) (b)(4) use during the manufacturing is not documented; for example during the Processing of process Validation batches (b)(4)

    8. Observation 10

      BPR missing process step duration

      The BPR does not document the duration of the (b)(4) step of the (b)(4) during production; for example, at (b)(4) (b)(4) the (b)(4) stage the (b)(4) (b)(4) is (b)(4)

    9. Observation 11

      Undocumented BPR measurement procedure

      An entry in page (b)(4) of the BPR for the (b)(4) processing step documents that (b)(4) of the (b)(4) (b)(4) were collected and measured. However, while questioning this BPR entry, it was reported (b)(4) (b)(4) that the operator measures the amount of The (b)(4) measurement is done The actual steps as to how the operator came up with the value, documented in the BPR, are not documented in the (b)(4) BPR or explained in an operating instruction procedure.

    10. Observation 12

      Returned product not checked by QA

      SOP 10-103 requires QA to check and sample products that are returned to the site. However, there is no data to show that QA checked the amount of batch (b)(4) returned to the firm on 2/28/11 and 3/16/11, respectively. It was reported that this product was returned from the USA due to the product cost being too high. The product was accepted by warehouse personnel and returned to product release inventory.

    11. Observation 13

      Water system valves, leak and no TOC

      A physical inspection of the water system revealed the following: (b)(4) in the water distribution line installed type valves were mounted (b)(4) valves were installed in such a way that may not allow for storage tank. These (b)(4) after the water (b)(4) complete drainage. All valves observed at the use water use points are the (b)(4) valve type. There was a water leak at the connection of the tubing to a pressure gauge after the (b)(4). No TOC test is performed.

    12. Observation 14

      Unstable balance table and improper calibration

      SOP 09-301 requires analytical balances to be placed on a vibration proof surface. However, inspection of the table used to hold Mettler Toledo analytical balance #JY-TP-12-01 revealed that the table vibrated to the touch. Also, one of the legs of the table appeared to be shorter than the other 3 legs and was supported by what appeared to be a folded carton. Also, the [illegible] check of the balance was performed using a (b)(4) mass grams weight when in fact the sample weight used in testing is in milligrams.

    13. Observation 15

      Unidentified uncalibrated weighing scale

      There was no identification, calibration record, or usage log on a scale found in the raw material weighing and dispensing room. Reportedly, this scale is used to weigh (b)(4) used in the product formulation and recorded in the BPR.

    14. Observation 16

      Undated loose batch records in desk

      There were several undated loose pages of partially completed batch production records for processing stages (b)(4) steps) in a drawer of a desk in the office used by production operators and management.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jun 17, 2026. It asked for a Form 483.

  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 + EIR on Jul 9, 2026. FDAgent holds no copy that FDA posted.

    1. Jun 17, 2026FDA-FOIA-2026-5873Form 483 + EIR· 1 of 4 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2026
Registrant
Qingdao Kangyuan Pharmaceutical Co., LtdD-U-N-S 529604063

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006512854 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006512854. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.