Drug Depot, LLC., dba APS Pharmacy
34911 Us Highway 19 N Ste 600, Palm Harbor, Florida, United States
FEI 3010621916
FDA has 3 inspections on file for Drug Depot, LLC., dba APS Pharmacy in Palm Harbor, Florida (FEI 3010621916), from 2016 to 2022. The latest ended on and was classified VAI, voluntary action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER · Division of Pharmaceutical Quality Operations II).
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection. They are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2016–2022
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 2 posted 483s not matched to an inspection
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
First pass air blockage, open unit with sterile product
Personnel conducted aseptic manipulations in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.
- FDCA 501(a)(2)(A)
Disruption of airflow from personnel movement
Personnel moved rapidly in the vicinity of open sterile units and instruments, which disrupted the airflow and increased the risk of bringing lesser quality air into the ISO 5 classified aseptic processing area.
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Aseptic manipulations blocking first-pass air
Personnel were observed conducting aseptic manipulations that blocked the movement of first pass air around an open unit, whether before or after it is filled with sterile product. Specifically, on 07/09/2018 I observed a sterile technician filling vials of Testosterone Cypionate/ Anastrozole*GS*Oil200MG/0.5MG/MLRM Injectable lot number 486380, in (b)(4) laminar ISO 5 classified bio-safety cabinet, break first pass unidirectional airflow at least four times by placing hands over an open top of the (b)(4) while (b)(4) drug product in a syringe during the fill operation. Since the January 2017 there have been [illegible] sterility failures which may be an indication of insanitary conditions.
- Observation 2
ISO-classified area difficult to clean
The ISO-classified area has difficult to clean, particle-generating, or visibly dirty equipment or surfaces. Specifically, caulking around joints of the ISO 5 area between the laminar flow hood and (b)(4) and on ceilings in the non-hazardous and hazardous areas were not smooth.
Show observation 3
- Observation 3
Hazardous drugs prepared in non-hazardous area
Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, since December 2017 lots of hazardous Human Chorionic Gonadotropin (HCG) were filled and (b)(4) in the non-hazardous ISO 5 classified area of the facility.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Sterilization process not validated
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, A. For the following four out of four products I reviewed, (b)(4) are used for the sterilization for the following drug products labeled as sterile: 1. Methylcobalamin (1 mg/mL) 2. Human Chorionic Gonadotropin (HCG) (3500 IU/vial and 5000 IU/vial) 3. Testosterone Cypionate (200 mg/mL) 4. Sermorelin (15 mg/vial) B. The (b)(4) and the practice of (b)(4) container/closures in (b)(4) has have not been validated. This includes the storage hold times for these container/closures. In addition, there are no written calibration procedures or actual calibration documentation available for your [illegible] and This includes lack of documentation for [illegible] is for glassware and finished product while preparing sterile drug products. 2. [illegible] of finished drug products (i.e., testosterone pellets), finished product vials, rubber vial stoppers, and utensils used in the filling of sterile drug products. 3. (b)(4) laboratory glassware, finished product vials, and stoppers are [illegible], that is, (b)(4) [illegible].
- Observation 2
Aseptic procedures not established/followed
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. Specifically, A. I observed the following aseptic deficiencies during the preparation of sterile drug products: 1. Personnel are not sanitizing items (e.g., bags containing vials, syringes, and glassware) prior to placing them into the laminar flow hood (ISO 5). 2. Personnel are placing their head inside the laminar flow hood while preparing sterile drug products. B. The media fills documented as being conducted by your technicians within the ISO 7 room and under the laminar flow hoods (ISO 5) were found to be deficient in that they do not accurately simulate current production processes and conditions that represent the most stressful/challenging conditions and optimize detection of any microbiological contamination. For example, there is no media fill data for your current operation of filling approximately (b)(4) glass Human Chorionic Gonadotropin vials (b)(4) for a prepared batch that uses (b)(4) glass vials, stoppers, caps that are sterilized in-house.
Show observations 3 to 9
- Observation 3
Environmental monitoring system inadequate
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Air (viable and non-viable) sampling within all classified areas is not performed during daily [illegible]. Personnel stated that sampling is only performed every [illegible]. B. There is no continuous or at least periodically monitoring of air pressure differentials during production from the ISO 7 room containing the ISO 5 hoods and the prep room (ISO 7) to the surrounding non-classified pharmacy area. C. For all classified areas, personnel stated that dynamic airflow pattern studies (i.e., smoke studies) had not been conducted in the laminar flow hoods inside your ISO room. D. Surface sampling within your laminar flow hoods is not conducted during daily operations. Personnel stated that (b)(4) is sampled (b)(4) on a (b)(4) basis. E. Personnel monitoring within all classified areas is not adequate based on the following: 1. Personnel monitoring (e.g., fingertip sampling) is not conducted during daily operations. Personnel stated that sampling is only conducted every (b)(4). 2. Your personnel's gowning materials have never been sampled after preparation of sterile drug products.
- Observation 4
Cleaning/disinfection procedures deficient
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. Personnel use non-sterile disinfectants (e.g., (b)(4)) to clean the laminar flow hoods where sterile drug products are prepared. B. No sporicidal agent is used to clean your classified areas, including the laminar flow hood where sterile drug products are prepared. C. No documentation was provided demonstrating disinfectant efficacy either by the firm or cleaning solution manufacturer.
- Observation 5
Inadequate protective gowning practices
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, I observed inconsistent and inadequate gowning practices during this inspection as described below: A. Gowning qualifications have not been conducted for your pharmacy personnel that prepare drug products in your ISO 7 room under the laminar flow hoods (ISO 5). B. The following non-sterile gowning components are used while preparing sterile drug products: • Gown • Facemask • Hairnet C. Personnel stated they use [illegible]. I observed personnel slide their hands from top to bottom of their gowns, after they hung them on the hooks in the gowning room.
- Observation 6
Sterility and preservative testing lacking
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements. Specifically, A. Your firm has not validated sterility testing to ensure substances in your product formulations do not interfere with the test and if they can detect low levels of organisms. In addition growth promotion testing is not conducted for media used for sterility testing in-house. B. Your firm has never performed testing to determine the preservative (i.e., (b)(4)) content for any of the sterile drug products I reviewed: • Methylcobalamin (1 mg/mL) • Testosterone Cypionate (200 mg/mL) C. Your firm has never tested the reconstitution time for any of the sterile lyophilized drug products I reviewed: • Human Chorionic Gonadotropin (HCG) (3500 IU/vial) • Human Chorionic Gonadotropin (HCG) (5000 IU/vial) • Sermorelin (15 mg/vial)
- Observation 7
Stability/BUD not supported by data
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use. Specifically, A. No documentation (potency and sterility data) could be provided to support your labeled beyond use date for the sterile drug products that I reviewed: Drug product BUD (days) Methylcobalamin (1 mg/mL) 90 Human Chorionic Gonadotropin (HCG) (3500 IU/vial) 180 Human Chorionic Gonadotropin (HCG) (5000 IU/vial) 180 Human Chorionic Gonadotropin (HCG) pre-filled syringe (200 IU/syringe) 45 Testosterone Cypionate (200 mg/mL) 180 Testosterone Cypionate pre-filled syringe (200 mg/mL) 90 Sermorelin (15 mg/vial) 180 17-A-OH-Progesterone caproate (PF) (250 mg/mL) 90 Procaine HCl 2% 30 B. There is no antimicrobial effectiveness testing for sterile drug products that your firm prepares that contain preservatives (e.g., (b)(4)) over the labeled shelf life: • Methylcobalamin (1 mg/mL) • Testosterone Cypionate (200 mg/mL) C. There is no written testing program designed to assess the stability characteristics of drug products.
- Observation 8
No supplier qualification/CoA verification
Each lot of a component, drug product containers, and closures liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use. Specifically, A. Your firm has no qualified vendor program and no documentation could be provided showing you have qualified any of your non-sterile bulk drug substance (e.g., (b)(4)) or component suppliers. B. Your firm has not verified that Certificate of Analysis (CoA) test results are reliable for any incoming bulk drug substance used in the preparation of sterile drug products.
- Observation 9
Containers/closures not properly sterilized
Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use. Specifically, A. Your firm's practice of (b)(4) lab glassware, vials and stoppers with non-sterile (b)(4) has not been verified that this process does not leave behind a chemical residue or introduce particles inside these containers and closures. B. Your firm does not depyrogenate vial stoppers that are used in the packaging of finished sterile drug products prepared at your facility.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations II · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010621916 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010621916. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.