Drug Depot Inc. dba APS Pharmacy Form 483, January 2016
FDA issued this Form 483 to Drug Depot Inc. dba APS Pharmacy in Palm Harbor, Florida (FEI 3010621916) at the end of a drug inspection that ended January 22, 2016. It lists 9 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jan 22, 2016
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jan 17, 2024
- 2,917 days after the inspection
The 9 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Sterilization process not validated
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, A. For the following four out of four products I reviewed, (b)(4) are used for the sterilization for the following drug products labeled as sterile: 1. Methylcobalamin (1 mg/mL) 2. Human Chorionic Gonadotropin (HCG) (3500 IU/vial and 5000 IU/vial) 3. Testosterone Cypionate (200 mg/mL) 4. Sermorelin (15 mg/vial) B. The (b)(4) and the practice of (b)(4) container/closures in (b)(4) has have not been validated. This includes the storage hold times for these container/closures. In addition, there are no written calibration procedures or actual calibration documentation available for your [illegible] and This includes lack of documentation for [illegible] is for glassware and finished product while preparing sterile drug products. 2. [illegible] of finished drug products (i.e., testosterone pellets), finished product vials, rubber vial stoppers, and utensils used in the filling of sterile drug products. 3. (b)(4) laboratory glassware, finished product vials, and stoppers are [illegible], that is, (b)(4) [illegible].
- 2
Aseptic procedures not established/followed
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. Specifically, A. I observed the following aseptic deficiencies during the preparation of sterile drug products: 1. Personnel are not sanitizing items (e.g., bags containing vials, syringes, and glassware) prior to placing them into the laminar flow hood (ISO 5). 2. Personnel are placing their head inside the laminar flow hood while preparing sterile drug products. B. The media fills documented as being conducted by your technicians within the ISO 7 room and under the laminar flow hoods (ISO 5) were found to be deficient in that they do not accurately simulate current production processes and conditions that represent the most stressful/challenging conditions and optimize detection of any microbiological contamination. For example, there is no media fill data for your current operation of filling approximately (b)(4) glass Human Chorionic Gonadotropin vials (b)(4) for a prepared batch that uses (b)(4) glass vials, stoppers, caps that are sterilized in-house.
- 3
Environmental monitoring system inadequate
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Air (viable and non-viable) sampling within all classified areas is not performed during daily [illegible]. Personnel stated that sampling is only performed every [illegible]. B. There is no continuous or at least periodically monitoring of air pressure differentials during production from the ISO 7 room containing the ISO 5 hoods and the prep room (ISO 7) to the surrounding non-classified pharmacy area. C. For all classified areas, personnel stated that dynamic airflow pattern studies (i.e., smoke studies) had not been conducted in the laminar flow hoods inside your ISO room. D. Surface sampling within your laminar flow hoods is not conducted during daily operations. Personnel stated that (b)(4) is sampled (b)(4) on a (b)(4) basis. E. Personnel monitoring within all classified areas is not adequate based on the following: 1. Personnel monitoring (e.g., fingertip sampling) is not conducted during daily operations. Personnel stated that sampling is only conducted every (b)(4). 2. Your personnel's gowning materials have never been sampled after preparation of sterile drug products.
- 4
Cleaning/disinfection procedures deficient
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. Personnel use non-sterile disinfectants (e.g., (b)(4)) to clean the laminar flow hoods where sterile drug products are prepared. B. No sporicidal agent is used to clean your classified areas, including the laminar flow hood where sterile drug products are prepared. C. No documentation was provided demonstrating disinfectant efficacy either by the firm or cleaning solution manufacturer.
- 5
Inadequate protective gowning practices
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, I observed inconsistent and inadequate gowning practices during this inspection as described below: A. Gowning qualifications have not been conducted for your pharmacy personnel that prepare drug products in your ISO 7 room under the laminar flow hoods (ISO 5). B. The following non-sterile gowning components are used while preparing sterile drug products: • Gown • Facemask • Hairnet C. Personnel stated they use [illegible]. I observed personnel slide their hands from top to bottom of their gowns, after they hung them on the hooks in the gowning room.
- 6
Sterility and preservative testing lacking
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements. Specifically, A. Your firm has not validated sterility testing to ensure substances in your product formulations do not interfere with the test and if they can detect low levels of organisms. In addition growth promotion testing is not conducted for media used for sterility testing in-house. B. Your firm has never performed testing to determine the preservative (i.e., (b)(4)) content for any of the sterile drug products I reviewed: • Methylcobalamin (1 mg/mL) • Testosterone Cypionate (200 mg/mL) C. Your firm has never tested the reconstitution time for any of the sterile lyophilized drug products I reviewed: • Human Chorionic Gonadotropin (HCG) (3500 IU/vial) • Human Chorionic Gonadotropin (HCG) (5000 IU/vial) • Sermorelin (15 mg/vial)
- 7
Stability/BUD not supported by data
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use. Specifically, A. No documentation (potency and sterility data) could be provided to support your labeled beyond use date for the sterile drug products that I reviewed: Drug product BUD (days) Methylcobalamin (1 mg/mL) 90 Human Chorionic Gonadotropin (HCG) (3500 IU/vial) 180 Human Chorionic Gonadotropin (HCG) (5000 IU/vial) 180 Human Chorionic Gonadotropin (HCG) pre-filled syringe (200 IU/syringe) 45 Testosterone Cypionate (200 mg/mL) 180 Testosterone Cypionate pre-filled syringe (200 mg/mL) 90 Sermorelin (15 mg/vial) 180 17-A-OH-Progesterone caproate (PF) (250 mg/mL) 90 Procaine HCl 2% 30 B. There is no antimicrobial effectiveness testing for sterile drug products that your firm prepares that contain preservatives (e.g., (b)(4)) over the labeled shelf life: • Methylcobalamin (1 mg/mL) • Testosterone Cypionate (200 mg/mL) C. There is no written testing program designed to assess the stability characteristics of drug products.
- 8
No supplier qualification/CoA verification
Each lot of a component, drug product containers, and closures liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use. Specifically, A. Your firm has no qualified vendor program and no documentation could be provided showing you have qualified any of your non-sterile bulk drug substance (e.g., (b)(4)) or component suppliers. B. Your firm has not verified that Certificate of Analysis (CoA) test results are reliable for any incoming bulk drug substance used in the preparation of sterile drug products.
- 9
Containers/closures not properly sterilized
Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use. Specifically, A. Your firm's practice of (b)(4) lab glassware, vials and stoppers with non-sterile (b)(4) has not been verified that this process does not leave behind a chemical residue or introduce particles inside these containers and closures. B. Your firm does not depyrogenate vial stoppers that are used in the packaging of finished sterile drug products prepared at your facility.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterDec 15, 2016CDER · 328 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3010621916, newest first.
- Form 483, June 2022Inspection ended Jun 17, 2022 · Posted Nov 7, 2022VAI
- Form 483, July 2018Inspection ended Jul 13, 2018 · Posted Jan 17, 2024VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.