Skip to content

Custom Compounding Center

11700 Kanis Rd, Little Rock, Arkansas, United States

FEI 3002401385

FDA has 2 inspections on file for Custom Compounding Center in Little Rock, Arkansas (FEI 3002401385), from 2015 to 2019. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published one citation from this inspection. It is listed below.

The most recent OAI inspection ended on Apr 9, 2015. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2015–2019
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 citation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Hazardous drugs, prevention of cross-contamination

      You produced hazardous drugs without providing adequate cleaning of work surfaces to prevent cross-contamination.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No sterilization process validation

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, A. On 03/31/2015, your firm's Owner/Pharmacist-in-Charge stated your firm failed to [illegible] processes used for the production equipment, [illegible] (ID # -) and the [illegible] used in the depyrogenation and sterilization of production glassware and B. On 03/30/2015, your firm's Owner/Pharmacist-in-Charge stated your firm [illegible] any [illegible] processes used to render produced drugs sterile. For example, during the production of Avastin (NDC#500242-0060) your firm failed to validate the repackaging operation which is used to render a non-sterile component sterile for the Supplier Lot# [illegible]/your firm's Lot# 03302015+4264@8. C. On 03/30/2015, during our walkthrough of your facility's Cleanroom / Chemotherapy room (ISO7 Classified), we observed your Pharmacy Technician exhibiting poor aseptic techniques in that: 1. Your firm's Pharmacy Technician was observed leaning forward, with elbows covering the ventilation grid inside the [illegible] (Model# -, [illegible]) ISO 5 Classified - while repackaging Avastin (NDC# 500242-0060), Supplier Lot# [illegible]/Firm's Lot# 03302015+4264@8. 2. Your firm's Pharmacy Technician was observed leaving the ISO 5 classified [illegible] where she was repackaging Avastin (NDC# 500242-0060), Supplier Lot # [illegible]/Firm's Lot #03302015+4264@8, entering the ISO7 classified Ante-room and Powder room to perform a task, only to return, spray the existing gloves with [illegible] and return to processing the current batch of product. Your technician failed to change gloves.

    2. Observation 2

      Inadequate filtered air/pressure validation

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, A. Your firm failed to adequately validate the following sterile and non-sterile drug production areas currently classified by our firm as an ISO7 in the dynamic state: Cleanroom (sterile production room, positive pressure), Cleanroom (chemotherapy room, negative pressure), Anti-room (positive pressure), and Powder room (positive pressure) in the prevention of contamination in the dynamic condition. B. On 03/30/2015, we observed three Magnehelic gauges on the exterior wall of the Powder Room (ISO 7 classified) leading to cleanroom areas failed to physically measure generated and maintained differential pressures levels in both static and dynamic states.

    Show observations 3 to 6
    1. Observation 3

      Deficient area separation and controls

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient. Specifically, A. During a review of your firm's 2014 - 2015 Environmental Monitoring analysis, smoke pattern studies, for sterile and non-sterile drug production ISO5 Classified (Sterile [illegible] Model #[illegible]) your [illegible] to perform these studies in the [illegible] and Non Sterile [illegible] dynamic state. On 4/1/2015, your firm's Owner/Pharmacist-in-Charge stated all smoke studies were completed in the [illegible] (b)(4) B. On 03/30/2015, we observed your firm's weigh scales in the Powder Room (ISO 7 classified) are environmentally exposed without adequate containment to prevent powder particulate cross-contamination of drug products during admixing. C. Your firm failed to define a written control system for the plastic slatted doors leading into all ISO classified areas to prevent drug product contamination.

    2. Observation 4

      Inadequate protective apparel and gowning

      Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, A. Your firm failed to require adequate protective apparel to protect drug products from contamination. For example your firm's Pharmacy Technician was observed having facial and neck areas exposed during the repackaging of Avastin (NDC #500242-0060), Supplier Lot [illegible]/Firm's Lot [illegible] 03302015+4264@8 1.25mg/0.05ml syringes. B. Your firm fails to require use of sterile hair nets and face masks during the production of sterile drug products. C. Your firm fails to require the continuous use of sterile gowning during the production of sterile drug products. For example on 3/30/2015, a sterile gown used by your firm's Pharmacy Technician was observed hanging on the corner of a stainless steel shelving located in the ISO7 Classified Ante-room. Your firm's procedure, Room Cleaning Procedures-Compounding Labs-Sterile & Non Sterile (SOP# 5.005, Implemented date 9/19/14), reports shelving cleaning occurs only [illegible]. Your firm reuses a single gown an entire drug production day.

    3. Observation 5

      No written stability testing program

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, on 03/30/2015, your firm's Owner/Pharmacist-in-Charge stated your firm failed to have a written stability program for all sterile and non-sterile drug products.

    4. Observation 6

      No written incoming component sampling

      Representative samples are not taken of each shipment of each lot of components for testing or examination. Specifically, on 03/30/2015, your firm's Owner/Pharmacist-in-Charge stated your firm failed to have a written procedure for receiving, inspecting, and accepting lots of non-sterile components utilized in the production of sterile finished drug products.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002401385 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002401385. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.