Custom Compounding Center Form 483, April 2015
FDA issued this Form 483 to Custom Compounding Center in Little Rock, Arkansas (FEI 3002401385) at the end of a drug inspection that ended April 9, 2015. It lists 6 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Apr 9, 2015
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jan 17, 2024
- 3,205 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
No sterilization process validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, A. On 03/31/2015, your firm's Owner/Pharmacist-in-Charge stated your firm failed to [illegible] processes used for the production equipment, [illegible] (ID # -) and the [illegible] used in the depyrogenation and sterilization of production glassware and B. On 03/30/2015, your firm's Owner/Pharmacist-in-Charge stated your firm [illegible] any [illegible] processes used to render produced drugs sterile. For example, during the production of Avastin (NDC#500242-0060) your firm failed to validate the repackaging operation which is used to render a non-sterile component sterile for the Supplier Lot# [illegible]/your firm's Lot# 03302015+4264@8. C. On 03/30/2015, during our walkthrough of your facility's Cleanroom / Chemotherapy room (ISO7 Classified), we observed your Pharmacy Technician exhibiting poor aseptic techniques in that: 1. Your firm's Pharmacy Technician was observed leaning forward, with elbows covering the ventilation grid inside the [illegible] (Model# -, [illegible]) ISO 5 Classified - while repackaging Avastin (NDC# 500242-0060), Supplier Lot# [illegible]/Firm's Lot# 03302015+4264@8. 2. Your firm's Pharmacy Technician was observed leaving the ISO 5 classified [illegible] where she was repackaging Avastin (NDC# 500242-0060), Supplier Lot # [illegible]/Firm's Lot #03302015+4264@8, entering the ISO7 classified Ante-room and Powder room to perform a task, only to return, spray the existing gloves with [illegible] and return to processing the current batch of product. Your technician failed to change gloves.
- 2
Inadequate filtered air/pressure validation
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, A. Your firm failed to adequately validate the following sterile and non-sterile drug production areas currently classified by our firm as an ISO7 in the dynamic state: Cleanroom (sterile production room, positive pressure), Cleanroom (chemotherapy room, negative pressure), Anti-room (positive pressure), and Powder room (positive pressure) in the prevention of contamination in the dynamic condition. B. On 03/30/2015, we observed three Magnehelic gauges on the exterior wall of the Powder Room (ISO 7 classified) leading to cleanroom areas failed to physically measure generated and maintained differential pressures levels in both static and dynamic states.
- 3
Deficient area separation and controls
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient. Specifically, A. During a review of your firm's 2014 - 2015 Environmental Monitoring analysis, smoke pattern studies, for sterile and non-sterile drug production ISO5 Classified (Sterile [illegible] Model #[illegible]) your [illegible] to perform these studies in the [illegible] and Non Sterile [illegible] dynamic state. On 4/1/2015, your firm's Owner/Pharmacist-in-Charge stated all smoke studies were completed in the [illegible] (b)(4) B. On 03/30/2015, we observed your firm's weigh scales in the Powder Room (ISO 7 classified) are environmentally exposed without adequate containment to prevent powder particulate cross-contamination of drug products during admixing. C. Your firm failed to define a written control system for the plastic slatted doors leading into all ISO classified areas to prevent drug product contamination.
- 4
Inadequate protective apparel and gowning
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, A. Your firm failed to require adequate protective apparel to protect drug products from contamination. For example your firm's Pharmacy Technician was observed having facial and neck areas exposed during the repackaging of Avastin (NDC #500242-0060), Supplier Lot [illegible]/Firm's Lot [illegible] 03302015+4264@8 1.25mg/0.05ml syringes. B. Your firm fails to require use of sterile hair nets and face masks during the production of sterile drug products. C. Your firm fails to require the continuous use of sterile gowning during the production of sterile drug products. For example on 3/30/2015, a sterile gown used by your firm's Pharmacy Technician was observed hanging on the corner of a stainless steel shelving located in the ISO7 Classified Ante-room. Your firm's procedure, Room Cleaning Procedures-Compounding Labs-Sterile & Non Sterile (SOP# 5.005, Implemented date 9/19/14), reports shelving cleaning occurs only [illegible]. Your firm reuses a single gown an entire drug production day.
- 5
No written stability testing program
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, on 03/30/2015, your firm's Owner/Pharmacist-in-Charge stated your firm failed to have a written stability program for all sterile and non-sterile drug products.
- 6
No written incoming component sampling
Representative samples are not taken of each shipment of each lot of components for testing or examination. Specifically, on 03/30/2015, your firm's Owner/Pharmacist-in-Charge stated your firm failed to have a written procedure for receiving, inspecting, and accepting lots of non-sterile components utilized in the production of sterile finished drug products.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterMar 16, 2016CDER · 342 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3002401385, newest first.
- Form 483, June 2019Inspection ended Jun 4, 2019 · Posted Jul 12, 2019VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.