Specialty Compounding LLC. Form 483, May 2015
FDA issued this Form 483 to Specialty Compounding LLC. in Cedar Park, Texas (FEI 3009815000) at the end of a drug inspection that ended May 5, 2015. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 5, 2015
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jan 17, 2024
- 3,179 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate media fill simulation procedures
Your firm has failed to establish adequate procedures for conducting appropriate media fill simulations. Specifically, Your most recent media fills dated 4/30/2014 and 10/1/2014 for each of the operators that work in the ISO 5 LAF hoods do not closely simulate planned production. For example, the (b) (4)
- 2
Unsuitable facility design and airflow control
Your firm has not ensured that your facility is suitably designed with respect to the flow of personnel, in-process materials, and finished sterile drugs; the need for room segregation and process separation; and the impact from heating ventilation and air conditioning (HVAC), air pressurization, and unidirectional airflow, to prevent contamination and other hazards to sterile drugs. Specifically, A. The smoke studies performed by your vendor in 9/2014 for ISO 5 LAF Hood # 1 indicated the presence of non-unidirectional airflow in the ISO 5 LAF Hood # 1, and specifically air backflow into the ISO-5. There was no evaluation of this finding. B. The "Sterile Processing Room" has a window used as a pass through for dirty glassware from the ISO 7 area to an unclassified area. Your firm has not determined whether there is an influx of air from the unclassified area into the ISO 7 when the window is opened.
- 3
Inadequate procedures preventing microbiological contamination
Your firm has failed to establish and implement adequate operational procedures designed to prevent microbiological contamination of drugs purporting to be sterile. Specifically, Your (b) (4) used for the depyrogenation of glassware used in aseptic processing was qualified on 3/24/2015 using the (b) (4) ((b) (4) (b) (4)). The directions for use for the test indicate that the (b) (4) (b) (4). To date, your firm has not determined where the (b) (4) (b) (4).
- 4
Missing cleaning procedures for sterile glassware
Your firm has not established adequate written Standard Operating Procedures to ensure proper maintenance of aseptic processing areas and equipment used in those areas. Specifically, Your firm has not established written procedures that describe the cleaning of glassware used in the production of sterile drug products.
- 5
Inaccurate finished product labeling BUD
Your firm failed to ensure the accuracy of the labels used in the finished preparation. Specifically, The product, Methylcobalamin/RG3 (90%)/Cyclodextrin/Nicotinamide 2mg/2mg/60mg/50mg/ml Nasal Spray, (lot #12222014@6), was produced on 12/22/2014. According to compounding records, the BUD for the product. Methylcobalamin/RG3 (90%)/Cyclodextrin/Nicotinamide 2mg/2mg/60mg/50mg/ml Nasal Spray, (lot #12222014@6, Production Date: 12/22/2014), was 2/5/2015. However, the label on the distributed product had a different BUD of 2/14/2015. The product was dispensed on 1/12/2015.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3009815000, newest first.
- Form 483, March 2013Inspection ended Mar 22, 2013 · Posted Jan 17, 2024OAI
- Form 483, July 2015FDA record date Jul 10, 2015 · Posted Jan 17, 2024
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.