Specialty Compounding, LLC
211 South Bell (Hwy 183 N), Cedar Park, Texas, United States
FEI 3009815000
FDA has 3 inspections on file for Specialty Compounding, LLC in Cedar Park, Texas (FEI 3009815000), from 2013 to 2015. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jul 23, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Sep 13, 2013. No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2013–2015
- 2 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 3 posted 483s not matched to an inspection
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate media fill simulation procedures
Your firm has failed to establish adequate procedures for conducting appropriate media fill simulations. Specifically, Your most recent media fills dated 4/30/2014 and 10/1/2014 for each of the operators that work in the ISO 5 LAF hoods do not closely simulate planned production. For example, the (b) (4)
- Observation 2
Unsuitable facility design and airflow control
Your firm has not ensured that your facility is suitably designed with respect to the flow of personnel, in-process materials, and finished sterile drugs; the need for room segregation and process separation; and the impact from heating ventilation and air conditioning (HVAC), air pressurization, and unidirectional airflow, to prevent contamination and other hazards to sterile drugs. Specifically, A. The smoke studies performed by your vendor in 9/2014 for ISO 5 LAF Hood # 1 indicated the presence of non-unidirectional airflow in the ISO 5 LAF Hood # 1, and specifically air backflow into the ISO-5. There was no evaluation of this finding. B. The "Sterile Processing Room" has a window used as a pass through for dirty glassware from the ISO 7 area to an unclassified area. Your firm has not determined whether there is an influx of air from the unclassified area into the ISO 7 when the window is opened.
Show observations 3 to 5
- Observation 3
Inadequate procedures preventing microbiological contamination
Your firm has failed to establish and implement adequate operational procedures designed to prevent microbiological contamination of drugs purporting to be sterile. Specifically, Your (b) (4) used for the depyrogenation of glassware used in aseptic processing was qualified on 3/24/2015 using the (b) (4) ((b) (4) (b) (4)). The directions for use for the test indicate that the (b) (4) (b) (4). To date, your firm has not determined where the (b) (4) (b) (4).
- Observation 4
Missing cleaning procedures for sterile glassware
Your firm has not established adequate written Standard Operating Procedures to ensure proper maintenance of aseptic processing areas and equipment used in those areas. Specifically, Your firm has not established written procedures that describe the cleaning of glassware used in the production of sterile drug products.
- Observation 5
Inaccurate finished product labeling BUD
Your firm failed to ensure the accuracy of the labels used in the finished preparation. Specifically, The product, Methylcobalamin/RG3 (90%)/Cyclodextrin/Nicotinamide 2mg/2mg/60mg/50mg/ml Nasal Spray, (lot #12222014@6), was produced on 12/22/2014. According to compounding records, the BUD for the product. Methylcobalamin/RG3 (90%)/Cyclodextrin/Nicotinamide 2mg/2mg/60mg/50mg/ml Nasal Spray, (lot #12222014@6, Production Date: 12/22/2014), was 2/5/2015. However, the label on the distributed product had a different BUD of 2/14/2015. The product was dispensed on 1/12/2015.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written complaint record must include
Written complaint records do not include, where known, the name and strength of the drug product, lot number, name of complainant, nature of complaint, and reply to complainant.
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, and drug product container with sufficient information to allow determination of any associated batch or lot of drug product.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Show 10 more citations
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Description of containers and closures
Batch production and control records do not include a description of drug product containers and closures used for each batch of drug product produced.
Complaint Investigation/Follow-Up Findings
Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Show 3 more citations
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.28Personnel responsibilities2 of 2
- 21 CFR 211.42Design and construction features2 of 2
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.165Testing and release for distribution2 of 2
- 21 CFR 211.166Stability testing2 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.167Special testing requirements1 of 2
Show all 12
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.198Complaint files1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3009815000 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3009815000. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.