Skip to content

MasterPharm LLC

11502 Liberty Ave Fl 2, South Richmond Hill, New York, United States

FEI 3005734706

FDA has 3 inspections on file for MasterPharm LLC in South Richmond Hill, New York (FEI 3005734706), from 2015 to 2020. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER · Division of Pharmaceutical Quality Operations I).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2015–2020
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
1 request, latest Apr 1, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Released sub-potent drug lot

      OBSERVATION 1 Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, Approximately (b)(4) Tadalafil 7 mg Capsules, Lot #01-22-2020: 02@19, BUD Date: 7/20/2020 were released, dispensed to patients, and continue to remain on the market despite the confirmed potency testing result of 80.4% (Specification - (b)(4) [illegible] %) reported for the sub-potent lot.

    2. Observation 2

      Dirty aseptic processing equipment/surfaces

      OBSERVATION 2 The ISO classified aseptic processing areas have difficult to clean, particle-generating and visibly dirty equipment and surfaces. Specifically, A) On 06/01/2020 and 06/08/2020, I observed dark black and brownish marks within the lower right corner of the material (b)(4) separating the sterile ISO 5 preparation area and non-sterile ISO 7 preparation area. There is no cleaning regimen for the (b)(6)(4) prior to use. The (b)(4) was used to transfer non-sterile drug product and materials, including filled syringes, (b)(4) and vials for the sterile producing of: 1) Morphine Sulfate/Clonidine HCL 10 MG/0.148MG/ML Intrathecal, Quantity Made: (b)(4) Lot #06-01-2020: 66@1, BUD: 06/04/2020 2) Hydromorphone HCL/Bupivacaine HCL 12.5mg/1.25MG/ML Intrathecal, Lot #06-01-2020: 03@3, Quantity Made: (b)(4), BUD: 06/04/2020 3) PPC/DC VIAL (Phosphatidylcholine/Deoxycholate) *FROZEN* Solution, 50/42MG/ML, Quantity Made: (b)(4), Lot #06-01-2020: 18@2, BUD: 07/16/2020 4) Hydromorphone HCL P/F, 6 MG/ML, Quantity Made: (b)(4) Lot #06-01-2020: 81@2, BUD: 06/04/2020 B) Hard-to-reach (b)(6)(2) areas used to enclose the direct compounding areas (DCAs) within the ISO 5 Cleanroom (b)(6)(4) are not cleaned. For example: On 06/08/2020, I observed the lack of cleaning by (b)(6) Sterile Operator, for the upper top half portions of the (b)(6)(4) areas used during the production of: 1) Morphine sulfate P/F 10 MG/ML, Lot #06-08-2020: 27@2 2) Morphine sulfate P/F 10 MG/ML, Lot #06-08-2020: 30@1 3) Fentanyl/Bupivacaine HCL/Clonidine HCL/Baclofen 0.8mg/30mg/0.025mg/0.2MG/ML, Lot #06-08-2020: 16@4 4) Morphine Sulfate/Bupivacaine HCL/Clonidine HCL, 4.5/10/0.44MG/ML, Lot #06-08-2020: 81@3 5) Trimix 1 (Papaverine HCL/Phentolamine Mesylate/Alprostadil) California, 30MG/1MG/10MCG/ML, Lot #06-08-2020: 45@5 C) On 06/08/2020, I observed visible black and brown stains on the ISO 5 Cleanroom ceiling tile stationed directly adjacent to the right of Table 2, direct compounding area (DCA), within Cleanroom (b)(4) used for aseptic processing of sterile drug products, including intrathecal syringes and vials. This tile is located approximately six (6) inches away from the (b)(4) surrounding the DCA.

    Show observations 3 to 7
    1. Observation 3

      Non-microbial contamination observed

      OBSERVATION 3 Non-microbial contamination was observed in your production area. Specifically, A) On 06/08/2020, I observed rust-like and reddish brown material on the heel of the sanitizer dispensing unit within the ISO 7 anteroom directly connected to ISO 5 Cleanroom. B) On 05/28/2020, I observed the following deficiencies within the ISO 7 hazardous non-sterile production room: 1) Visible white product residue directly on shelves used to store hazardous API and inactive ingredients within the ISO 7 hazardous non-sterile production room. This is in spite of the room being last used and cleaned on 05/27/2020 as per the Director of Pharmacy Operations and cleaning log of the production area. 2) Chipped and chipping metallic coating directly on top of a flammable container used to store alcohol-based materials used within the ISO 7 hazardous non-sterile production room. C) On 05/28/2020, I observed chipped and chipping coating/paint material as well as brown stains on the (b)(4) near product contact surfaces used to [illegible] non-sterile preparation creams, including: Benzocaine, Lidocaine, Tetracaine 20/10/10% cream, 05-28-2020 00@1, BUD: 08/26/2020.

    2. Observation 4

      Hazardous drugs cross-contamination risk

      OBSERVATION 4 Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, Non-dedicated work surfaces and utensils, including mortar pestles, mixing spoons, spatulas, and glassware, are shared for production operations between hazardous and non-hazardous non-sterile drug products. In addition, you do not use deactivating agents for removal of hazardous ingredients on shared utensils. This includes the following drug products, which were prepared and produced using the hazardous non-sterile production room: A) Non-sterile preparation of Mitomycin (b)(4) ~0.4 MG/ML solution, Lot Number: 05-27-2020: 10@1, BUD: 07/11/2020. Date Made: 05/27/2020 B) Production of Formula 82 M Minoxidil/Tretinoin/Fluocinolone Acetonide 5/0.01%/0.01% Solution, Lot #: 05-27-2020: 40@10, BUD: 11/22/2020, Date Made: 05/27/2020 C) Production of HCG Sublingual Mini 400 IU Troche, (b)(4) each, Qty [illegible] Lot #: 01-14-2020: 44@3, BUD: 05/16/2020, Date Made: 01/14/2020 D) Production of Formula 82M Minoxidil/Tretinoin/Fluocinolone Acetonide 5/0.01%/0.01% Solution, Lot #: 01-14-2020: 42@16, BUD: 07/07/2020, Date Made: 01/14/2020 E) Production of Formula 82D (b)(4) Minoxidil/Tretinoin/Fluocinolone Acetonide/Dutasteride 5/0.01/0.01/0.75%, Lot #: 01-14-2020: 04@9, BUD: 07/07/2020, Date Made: 01/14/2020

    3. Observation 5

      ISO-5 not certified dynamically

      OBSERVATION 5 ISO-5 classified areas were not certified under dynamic conditions. Specifically, Unidirectional airflow was not verified under operational conditions. For example: A) Smoke studies conducted within the ISO Class 5 areas are inadequate. The studies did not include evaluation of constant unidirectional HEPA airflow for sterile drug product solutions being (b)(4) [illegible]. B) The smoke study videos, Dated: 03/26/2020, representing (b)(6)(4) of vials and syringes did not include the transfer of starting materials into the ISO Class 5 areas to demonstrate unidirectional airflow away from sterile product under dynamic conditions.

    4. Observation 6

      Inadequate personnel sampling technique

      OBSERVATION 6 There is a lack of adequate personnel sampling. Specifically, A) On 06/08/2020, (b)(5)(6) Sterile Operator, was observed to spray his gloved hands with (b)(4) spray immediately before fingertip personnel monitoring. B) The same sterile operator was observed to quickly and lightly touch the (b)(4) plates with his fingertips and thumbs as opposed to slowly rolling each fingertip and thumb on the (b)(4) surface with adequate pressure to ensure recovery of potential microbes.

    5. Observation 7

      Poor airflow/pressure monitoring

      OBSERVATION 7 Your facility design allowed the influx of poor quality air into a higher classified area. Specifically, There is no gauge which measures the pressure differentials of airflow between the ISO 7 hazardous negative pressure room, which houses the ISO 5 (b)(4), and the ISO 7 anteroom used for gowning.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic process stimulation testing

      Failure to conduct adequate aseptic process stimulation (APS). Specifically, (A) failure to submit the vials produced from the APS for sterility testing in a timely manner. (B) failure to submit all vials produced from the APS for sterility testing.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Aseptic area maintenance and smoke studies

      OBSERVATION 1 Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. a). Smoke studies were not performed under dynamic conditions to verify that operators, processing equipment or activities of the ISO 5 non-hazardous clean room (aka Clean Room (b)(4)) do not alter or impede the unidirectionality of air from the HEPA filters to the ISO 5 processing stations where drug products are aseptically processed. Similarly, smoke studies were not performed under dynamic conditions for the ISO 7 hazardous clean room (aka Clean Room (b)(4)), nor the ISO 5 (b)(4) and the ISO 5 (b)(4) within that room. b). During the processing of Morphine/Bupivacaine/Cionidine Intrathecal syringe lot 04-22-2015:53@5 on 4/22/15 in Clean Room (b)(4), I observed the following: On the ISO 5 workstation where open containers of sterile solutions and sterile equipment were being manipulated, there was clutter including several plastic bins either containing alcohol wipes or the paper batch record contained within a plastic cover.

    2. Observation 2

      Environmental monitoring deficiencies

      OBSERVATION 2 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. a). Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm only monitors viable air counts (b)(4) and during the (b)(4) cleanroom certification by an outside vendor; lastly on 10/29/14. b). Environmental monitoring for non-viable particulates in the ISO 5 zones is not performed under dynamic conditions. The firm only monitors non-viable air counts during the (b)(4) cleanroom certification by an outside vendor; lastly on 10/29/14. c). The work surfaces, inside the ISO 5 hoods, are not tested for microbial contamination at least daily during periods of production and at the end of operations. This monitoring is only performed (b)(4). d). The ISO 5 non-hazardous clean room and the ISO 7 hazardous clean room, the respective ISO 7 anterooms, and the unclassified surrounding areas are not continuously monitored for air pressure differentials during production. The only times readings are monitored are at (b)(4) for the ISO 5 clean room only and its anteroom. Pressure differentials are not monitored between the ISO 7 hazardous clean room and its anteroom, nor between that anteroom and the surrounding unclassified areas.

    Show observations 3 to 7
    1. Observation 3

      Cleaning and disinfecting program inadequate

      OBSERVATION 3 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. a). Sporicidal agents are not used to disinfect the ISO 5 surfaces. b). No disinfectant effectiveness studies have been performed to determine if disinfection agents are effective in aseptic processing areas. Disinfectants used (b)(4) are (b)(4) on a (b)(4) basis and (b)(4) which is used (b)(4).

    2. Observation 4

      Sterility procedures and validation lacking

      OBSERVATION 4 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. a). [illegible] are prepared for various products from non-sterile ingredients. These [illegible] can be held for up to (b)( ) days as for Papaverine HCL. Your firm has not conducted any hold time studies to support the stability/sterility over the time periods that [illegible] are stored. b). You have not validated the (b)(4) sterilization used for two of your injectable drug products, such as Triamcinolone Suspension 40 mg/ml Injection, within your (b)(4).

    3. Observation 5

      Incomplete sterility and endotoxin testing

      OBSERVATION 5 Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Your firm does not test every sterile drug lot produced for sterility or endotoxins. Sterile drugs produced from non-sterile components are tested for sterility and endotoxins only for batches (b)(4).

    4. Observation 6

      No separation for beta-lactam processing

      OBSERVATION 6 The separate or defined areas necessary to prevent contamination or mix-ups are deficient. There are no separate facilities, for processing operations, to prevent contamination from the beta-Lactam injectable drug that you process - Ceftazidime syringe. This beta-Lactam powder, which is contained in glass vials, is processed in the same ISO 5 hood as are sterile injectable non beta-Lactam drugs. There is no assurance that a potential breakage of the glass vial and consequent powder spill would not contaminate other sterile drug products.

    5. Observation 7

      Stability testing and BUD support missing

      OBSERVATION 7 There shall be a written testing program designed to assess the stability characteristics of drug products. The results of such stability testing shall be used in determining appropriate storage conditions and expiration dates. Your firm has not tested for sterility or potency over the assigned Beyond Use Date (BUD) for all of your sterile drug products. For example, your firm has not conducted complete testing to support the BUDs such as 180 days for Estradiol subcutaneous pellets at room temperature. You have no stability studies to assure that the sterility and potency will be maintained over the time period of the BUD.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Apr 1, 2026. It asked for a Form 483.

  • Inspection ending Jun 15, 2020OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Apr 1, 2026FDA-FOIA-2026-3191Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005734706 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005734706. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.