Master Pharm LLC Form 483, May 2015
FDA issued this Form 483 to Master Pharm LLC in South Richmond Hill, New York (FEI 3005734706) at the end of a drug inspection that ended May 6, 2015. It lists 7 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 6, 2015
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jan 17, 2024
- 3,178 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Aseptic area maintenance and smoke studies
OBSERVATION 1 Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. a). Smoke studies were not performed under dynamic conditions to verify that operators, processing equipment or activities of the ISO 5 non-hazardous clean room (aka Clean Room (b)(4)) do not alter or impede the unidirectionality of air from the HEPA filters to the ISO 5 processing stations where drug products are aseptically processed. Similarly, smoke studies were not performed under dynamic conditions for the ISO 7 hazardous clean room (aka Clean Room (b)(4)), nor the ISO 5 (b)(4) and the ISO 5 (b)(4) within that room. b). During the processing of Morphine/Bupivacaine/Cionidine Intrathecal syringe lot 04-22-2015:53@5 on 4/22/15 in Clean Room (b)(4), I observed the following: On the ISO 5 workstation where open containers of sterile solutions and sterile equipment were being manipulated, there was clutter including several plastic bins either containing alcohol wipes or the paper batch record contained within a plastic cover.
- 2
Environmental monitoring deficiencies
OBSERVATION 2 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. a). Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm only monitors viable air counts (b)(4) and during the (b)(4) cleanroom certification by an outside vendor; lastly on 10/29/14. b). Environmental monitoring for non-viable particulates in the ISO 5 zones is not performed under dynamic conditions. The firm only monitors non-viable air counts during the (b)(4) cleanroom certification by an outside vendor; lastly on 10/29/14. c). The work surfaces, inside the ISO 5 hoods, are not tested for microbial contamination at least daily during periods of production and at the end of operations. This monitoring is only performed (b)(4). d). The ISO 5 non-hazardous clean room and the ISO 7 hazardous clean room, the respective ISO 7 anterooms, and the unclassified surrounding areas are not continuously monitored for air pressure differentials during production. The only times readings are monitored are at (b)(4) for the ISO 5 clean room only and its anteroom. Pressure differentials are not monitored between the ISO 7 hazardous clean room and its anteroom, nor between that anteroom and the surrounding unclassified areas.
- 3
Cleaning and disinfecting program inadequate
OBSERVATION 3 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. a). Sporicidal agents are not used to disinfect the ISO 5 surfaces. b). No disinfectant effectiveness studies have been performed to determine if disinfection agents are effective in aseptic processing areas. Disinfectants used (b)(4) are (b)(4) on a (b)(4) basis and (b)(4) which is used (b)(4).
- 4
Sterility procedures and validation lacking
OBSERVATION 4 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. a). [illegible] are prepared for various products from non-sterile ingredients. These [illegible] can be held for up to (b)( ) days as for Papaverine HCL. Your firm has not conducted any hold time studies to support the stability/sterility over the time periods that [illegible] are stored. b). You have not validated the (b)(4) sterilization used for two of your injectable drug products, such as Triamcinolone Suspension 40 mg/ml Injection, within your (b)(4).
- 5
Incomplete sterility and endotoxin testing
OBSERVATION 5 Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Your firm does not test every sterile drug lot produced for sterility or endotoxins. Sterile drugs produced from non-sterile components are tested for sterility and endotoxins only for batches (b)(4).
- 6
No separation for beta-lactam processing
OBSERVATION 6 The separate or defined areas necessary to prevent contamination or mix-ups are deficient. There are no separate facilities, for processing operations, to prevent contamination from the beta-Lactam injectable drug that you process - Ceftazidime syringe. This beta-Lactam powder, which is contained in glass vials, is processed in the same ISO 5 hood as are sterile injectable non beta-Lactam drugs. There is no assurance that a potential breakage of the glass vial and consequent powder spill would not contaminate other sterile drug products.
- 7
Stability testing and BUD support missing
OBSERVATION 7 There shall be a written testing program designed to assess the stability characteristics of drug products. The results of such stability testing shall be used in determining appropriate storage conditions and expiration dates. Your firm has not tested for sterility or potency over the assigned Beyond Use Date (BUD) for all of your sterile drug products. For example, your firm has not conducted complete testing to support the BUDs such as 180 days for Estradiol subcutaneous pellets at room temperature. You have no stability studies to assure that the sterility and potency will be maintained over the time period of the BUD.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterJan 8, 2016CDER · 247 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3005734706, newest first.
- Form 483, June 2020Inspection ended Jun 15, 2020 · Posted Jul 29, 2020OAI
- Form 483, January 2017Inspection ended Jan 30, 2017 · Posted Jan 17, 2024VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.