FDA issued this Form 483 to Vann Healthcare Services Inc in Glasgow, Kentucky (FEI 1000220363) at the end of a drug inspection that ended September 24, 2014. It lists 7 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 24, 2014
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jan 17, 2024
- 3,402 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate aseptic gowning for operators
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform. Specifically, The gown worn by the operator performing aseptic manipulations on Sept. 10, 2014 in the ISO 5 laminar flow hood was not sterile and it did not grip and cover the wrists and the V-neck gown did not cover the operator's upper chest.
- 2
Sterilization processes not validated
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, a. The [illegible] sterilization process for Lidocaine 4% injectable and the [illegible] sterilization process for Hydroxyprogesterone caproate injection have not been validated. b. The [illegible] for the [illegible] stoppers used for Hydroxyprogesterone caproate injection 250 mg/ml has not been validated. c. Media fills have not been conducted to validate the aseptic processes performed in the ISO 5 laminar flow hood. d. [illegible] testing, such as a [illegible] test, is not performed for products sterilized by [illegible]
- 3
No sterility and endotoxin testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, There is no sterility or endotoxin test data for: a. Lidocaine 4% injectable with a 60 day beyond use period at refrigerated storage. b. Epinephrine 1:1000 injection with a 30 day beyond use period at room temperature storage. c. Hydroxyprogesterone caproate injection, 250 mg/ml, with a 90 day beyond use period at room temperature storage.
- 4
No stability program for beyond-use dates
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, There is no potency test data to support the beyond use dating periods assigned for: a. Lidocaine 4% injectable with a 60 day beyond use period at refrigerated storage. b. Epinephrine 1:1000 injection with a 30 day beyond use period at room temperature storage. c. Hydroxyprogesterone caproate injection, 250 mg/ml, with a 90 day beyond use period at room temperature storage. There is also no test data to support antimicrobial effectiveness throughout the labeled beyond use period for this product.
- 5
No smoke studies or pressure monitoring
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, a. There are no smoke studies conducted under dynamic conditions in the ISO 5 laminar flow hood where aseptic operations are performed to verify there is no obstruction or alteration of the HEPA-filtered air. b. There is no continuous monitoring of differential air pressure between the ISO 5 laminar flow hood where aseptic operations are performed and the adjacent areas during production.
- 6
No environmental monitoring in ISO 5
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, There is no monitoring of viable particles, non-viable particles, work surfaces or personnel in the ISO 5 laminar flow hood where aseptic operations are performed.
- 7
No sporicidal disinfectant for ISO 5
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions. Specifically, Sporicidal disinfectants are not used to clean/disinfect the ISO 5 laminar flow hood.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 1000220363, newest first.
- Form 483, November 2015FDA record date Nov 13, 2015 · Posted Jan 17, 2024
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.