Vann Healthcare Services Inc
1220 N Race St, Glasgow, Kentucky, United States
FEI 1000220363
FDA has 3 inspections on file for Vann Healthcare Services Inc in Glasgow, Kentucky (FEI 1000220363), from 2014 to 2015. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Sep 2, 2016 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent has not matched a posted Form 483 to it.
The most recent OAI inspection ended on Sep 24, 2014. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2014–2015
- 1 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 3
- 2 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic gowning for operators
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform. Specifically, The gown worn by the operator performing aseptic manipulations on Sept. 10, 2014 in the ISO 5 laminar flow hood was not sterile and it did not grip and cover the wrists and the V-neck gown did not cover the operator's upper chest.
- Observation 2
Sterilization processes not validated
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, a. The [illegible] sterilization process for Lidocaine 4% injectable and the [illegible] sterilization process for Hydroxyprogesterone caproate injection have not been validated. b. The [illegible] for the [illegible] stoppers used for Hydroxyprogesterone caproate injection 250 mg/ml has not been validated. c. Media fills have not been conducted to validate the aseptic processes performed in the ISO 5 laminar flow hood. d. [illegible] testing, such as a [illegible] test, is not performed for products sterilized by [illegible]
Show observations 3 to 7
- Observation 3
No sterility and endotoxin testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, There is no sterility or endotoxin test data for: a. Lidocaine 4% injectable with a 60 day beyond use period at refrigerated storage. b. Epinephrine 1:1000 injection with a 30 day beyond use period at room temperature storage. c. Hydroxyprogesterone caproate injection, 250 mg/ml, with a 90 day beyond use period at room temperature storage.
- Observation 4
No stability program for beyond-use dates
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, There is no potency test data to support the beyond use dating periods assigned for: a. Lidocaine 4% injectable with a 60 day beyond use period at refrigerated storage. b. Epinephrine 1:1000 injection with a 30 day beyond use period at room temperature storage. c. Hydroxyprogesterone caproate injection, 250 mg/ml, with a 90 day beyond use period at room temperature storage. There is also no test data to support antimicrobial effectiveness throughout the labeled beyond use period for this product.
- Observation 5
No smoke studies or pressure monitoring
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, a. There are no smoke studies conducted under dynamic conditions in the ISO 5 laminar flow hood where aseptic operations are performed to verify there is no obstruction or alteration of the HEPA-filtered air. b. There is no continuous monitoring of differential air pressure between the ISO 5 laminar flow hood where aseptic operations are performed and the adjacent areas during production.
- Observation 6
No environmental monitoring in ISO 5
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, There is no monitoring of viable particles, non-viable particles, work surfaces or personnel in the ISO 5 laminar flow hood where aseptic operations are performed.
- Observation 7
No sporicidal disinfectant for ISO 5
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions. Specifically, Sporicidal disinfectants are not used to clean/disinfect the ISO 5 laminar flow hood.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000220363 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000220363. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.