Revive Rx LLC Form 483, May 2022
FDA issued this Form 483 to Revive Rx LLC in Houston, Texas (FEI 3016710945) at the end of a drug inspection that ended May 4, 2022. It lists 9 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Sep 27, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 4, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Sep 27, 2022
- 146 days after the inspection
The 9 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Poor aseptic technique blocking first air
Personnel were observed conducting aseptic manipulations or placing equipment/supplies in an area that blocked the movement of first pass air around an open unit, whether before or after it is filled with sterile product Specifically, A. On 4/26/2022 aseptic processing visual observations were made of the sterile drug product, (b)(4) Sterile Solution for Injection, Lot # (b)(4) BUD 10/23/2023, your firm pharmacy technician while placing rubber stoppers in finished product filled vials, was observed reaching over open vials. Following our discussion regarding poor aseptic techniques, your firm decided to dispose of this observed sterile lot. B. On 4/19/2022, while visually observing the aseptic processing of the sterile drug product, (b)(4), Lot # (b)(4), BUD 7/31/22, I observed your firm pharmacy technician use poor aseptic techniques in the positioning of the syringe to form the connection with the tubing which inhibited the presence of 1st air when forming the connections between each syringe fill. Following our discussion regarding poor aseptic techniques, your firm decided to dispose of this observed sterile lot. C. On 4/19/2022, while visually observing the aseptic processing of the sterile drug product, (b)(4), Lot # (b)(4), BUD 7/31/22, I observed both your PIC and pharmacy technician failed to disinfect sterile gloves prior to returning and place processing components inside ISO 5 BSC, while placing drug components into and removing trash from the BSC during processing of the sterile drug product. Following our discussion regarding poor aseptic techniques, your firm decided to dispose of this observed sterile lot.
- 2
Non-pharmaceutical grade sterilizing filter used
The (b)(4) intended to render final product sterile is not adequate to accomplish (b)(4) and/or is not pharmaceutical grade. Specifically, your firm fail to use sterile pharmaceutical grade (b)(4) during the processing of sterile drug products. For example, your firm uses a (b)(4), during the aseptic processing of the finished sterile drug product, Dexamethasone 24 mg/ml Sterile Solution pH 7. A review of your firm Production Log, I found 2 Lots produced that remain within expiry, Lot # 585669 (BUD 6/18/2022) and 668512 (BUD 8/15/2022). There have been 6 (six) patient-prescriptions dispensed from the aseptically process lots.
- 3
Inadequate HEPA coverage over sterile exposure areas
There is inadequate HEPA filter coverage or airflow over the area to which sterile product is exposed. Specifically, your firm has (b)(4) Systems in the cleanroom. (b)(4) does not appear to have enough HEPA filters in proper locations to provide adequate coverage to ensure ISO 5 environment is maintained from the ISO 5 BSC used for aseptic processing, to the (b)(4) and from the (b)(4) to the (b)(4) crimping station. This is a repeat observation.
- 4
Filter integrity testing not adequately performed
(b)(4) integrity testing to the (b)(4) was not performed. Specifically, your firm failed to adequately test and record the results from (b)(4) testing of the Sterile (b)(4) On 4/19/2022 and 4/26/2022, I observed your firm perform a (b)(4) test on the (b)(4) used to render the process drugs, (b)(4), Lot # (b)(4), BUD 7/31/22 and (b)(4) Sterile Solution for Injection (Continuation Dose), Lot # (b)(4) 10/23/2023, respectively, by your firm pharmacy technician. She was unable to adequately provide sufficient pressure using a (b)(4) syringe to deliver the (b)(4) which would test the (b)(4) to the manufacturer's specification. Your firm following our discussion of observed deficiencies disposed of both aseptically processed lots.
- 5
Sinks drains present near ISO 5 area
Sinks or drains are present in the cleanroom where the ISO 5 area is located. Specifically, your firm's (b)(4) system, located approximately (b)(4) feet apart within the ISO 7 Buffer Room/Cleanroom, require water to drained from the unit using a (b)(4) plastic bucket that was in your firm's ISO 8 Ante Room/Gowning at the completion of a cycle. Your firm's (b)(4) are located adjacent to ISO 5 BSC and the ISO 5 LAFU used for aseptic processing and (b)(4) crimping equipment respectively.
- 6
Unsealed ceiling tiles and sprinkler in cleanrooms
Unsealed, loose ceiling tiles were observed in your cleanroom. Specifically, I observed an exposed/unsealed fire sprinkler head within your firm's ISO 8 Ante Room/Gowning, and ISO 7 HD Anteroom/Prep Room, and ISO 7 Buffer Room/Cleanroom along with unsealed ceiling tiles.
- 7
Dirty difficult-to-clean ISO classified surfaces
The ISO-classified have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. Specifically, foreign particulates were observed on the top of the firm's ISO 5 BSC, ISO 5 LAFU and (b)(4) systems located in the ISO 7 Non-Hazardous Buffer Room.
- 8
Inadequate dynamic smoke studies
Cleanroom smoke studies conducted in cleanroom under dynamic conditions are inadequate. Specifically, your firm's smoke studies conducted as part of your firm August 18, 2021, Cleanroom re-certification is inadequate. For example, your firm's smoke studies failed to include and assess complex intervention(s) within your firm's ISO 5 BSC as part of the unit's recertification process.
- 9
Sterile glassware exposed to less than ISO 5
(b)(4) glassware used in the processing of sterile drug product is exposed to less than ISO 5 air quality. Specifically, your firm failed to ensure (b)(4) glassware used in aseptic processing is not exposed to less than ISO 5 air. For example, on 4/19/2022, your firm was observed using an uncovered glass beaker that had undergone (b)(4), used in the processing of the sterile drug product, (b)(4) vial for injection, Lot #(b)(4), BUD 7/31/22 within your firm's ISO 7 HD Ante Room and ISO 7 Non-Hazardous Buffer Room. The breaker contains the bulk (b)(4) drug product, (b)(4) during mixing of drug components and transfer prior to (b)(4) within the ISO 7 Non-Hazardous Buffer Room.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3016710945, newest first.
- Form 483, March 2026FDA record date Mar 27, 2026 · Posted Apr 22, 2026
- Form 483, February 2025Inspection ended Feb 7, 2025 · Posted Mar 28, 2025OAI
- Form 483, August 2021Inspection ended Aug 6, 2021 · Posted Oct 28, 2021OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.