FDA has 4 inspections on file for Revive Rx LLC in Houst on, Texas (FEI 3016710945), from 2021 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Feb 7, 2025. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
4, 2021–2026
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
4 of 4
Form 483s posted by FDA
↗
4 posted
Requested under FOIA
5 requests, latest FY2023
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Persistent environmental microbial contamination

      Microbial contamination was present in the ISO 5 area and areas adjacent to production areas. Specifically, A. Your environmental monitoring data shows persistent and repeated recovery of microorganisms, including mold and spore-forming bacteria, in both ISO Class 5 and ISO 7 classified areas. Recoveries in ISO 5 areas: • 3/5/2025: 1 CFU Gram-positive rods (not identified) recovered post-batch in Hood<1>< > • 4/3/2025: 1 CFU Gram-positive rods (not identified) recovered post-batch in Hood • 4/8/2025: 1 CFU Gram-positive rods (not identified) recovered post-batch in Hood • 4/8/2025: 1 CFU Gram-positive rods (not identified) recovered post-batch in Hood • 4/29/2025: 1 CFU (not stained, not identified) recovered post-batch in Hood (b>< > - • 5/12/2025: 1 CFU (not stained, not identified) recovered post-batch in Hood • 6/11/2025: 1 CFU Gram-positive rods identified as Streptomyces olivaceous recovered in Hood • 8/5/2025: 1 CFU identified as fungus Penicillium oxalicum recovered post-batch in Hood • 8/15/2025: 1 CFU Gram-positive rods (not identified) recovered in Hood • 9/8/2025: 1 CFU identified as fungus Scolecobasidium dendroides recovered in Hood • 9/10/2025: 1 CFU identified as fungus Penicillium citrinum recovered in Hood • 1/20/2026: 2 CFU identified as Bacillus safensis recovered in Hood • 1/26/2026: 1 CFU identified as fungus Paenibacillus sp recovered in Hood Recoveries in ISO 7 areas: • 10/14/2025: 54 CFU consisting of Micrococcus luteus, Staphylococcus hominis, Staphylococcus epidermidis, Mixta calida, Aspergillus austroafricanus / fructus / griseoaurantiacus / protuberus / tabacinus / versicolor, Dietzia sp. oral taxon recovered in Anteroom • 11/12/2025: 4 CFU fungus Hamigera inflata insecticola recovered in Prep room • 11/12/2025: 2 CFU fungus Aspergillus hiratsukae / shendaweii recovered in Prep room. B. Organism Identification Incomplete: Most of the microbial recoveries (18 of 29 recoveries) are documented as "Not identified," preventing your firm from determining the source of contamination (environmental vs. operator-derived) and implementing appropriate corrective actions. C. Persistent Contamination: The repeated recovery of microorganisms in the same locations (e.g., multiple recoveries in Hood) over a 12-month period indicates that corrective actions, if implemented, have been ineffective. D. Inadequate cleaning and disinfection: On 6/17/2025, following a breach cleaning of the Anteroom, viable air sampling recovered 10 CFU consisting of 2 Gram-positive rods and 2 Gram negative rods (not identified). This elevated recovery immediately following a breach clean which consists of cleaning (l:>)(4) times with (o)(4) followed by (o)(4) (1:5)(4) times indicates inadequate cleaning and disinfection. E. No Enhanced Monitoring: Following microbial recoveries, your firm does not perform additional environmental monitoring to verify that cleaning and corrective actions have eliminated the source of contamination. THIS IS A REPEAT OBSERVATION.

    2. Observation 2

      Inadequate personnel monitoring

      Lack of adequate personnel sampling. Specifically, Personnel monitoring for your operators is performed during the (6) (4) gowning qualification. After that personnel monitoring is performed during the [(I:)) (4] gowning competency assessment and (6) (4) media fill qualifications. No routine personnel monitoring is performed upon completion of production batches. Colonies belonging to human flora were isolated from ISO 5 Hoods during production: • Hood — Streptomyces olivaceous, during production of Tirzepatide Lot# 12246565 on 7/10/2025 • Hood Micrococcus luteus during production of Tirzepatide Lot #s 14031295 and 14162530 on 12/8/25 and 12/18/25. • Hood Micrococcus luteus during media fill on 3/24/2025 • Hood Micrococcus luteus during production of Semaglutide Lot# 14427530 on 1/12/26 • Hood Corynebacterium ureiceler during production of NAD+ Lot# 12231180 on 7/9/2025. All the recovered isolates were not identified. However, after Gram staining, the firm categorized the rest of the unidentified colonies to be of human origin. In addition, the review of the ([(lj) (4)] gowning qualification revealed that at least (6) (4) of the operators failed their ([(t)) (4)] gowning competency. The ([(t)) (4)] gowning qualification also revealed a supervisor failed the gowning competency. Another Supervisor failed media fill qualification. THIS IS A REPEAT OBSERVATION.

    Show observations 3 to 5
    1. Observation 3

      Static-only smoke studies

      Smoke studies were not performed under dynamic conditions. Specifically, Your firm conducted smoke studies on 2/9/2026 only under static conditions in Hoods and located in positive pressure clean room. These two ISO Class 5 primary engineering controls are used to compound injectable sterile drug products. The review of smoke studies performed in these hoods, in static conditions, showed empty hoods with single stream of smoke introduced towards the HEPA filter face. Your smoke studies under static conditions only do not provide an assurance that the first air from HEPA filters is maintained over critical sites (e.g. [(lj) (4) bag filled with compounded drug, [(lj) (4) tubing, vials, vial stoppers) when operators position their hands and arms in the hood or when equipment and materials are arranged as during actual production, thereby creating conditions whereby sterile drug products may become contaminated. Since 09/26/2025 your firm has compounded approximately (batches) of sterile drug products in Hood and since 12/26/2025 batches in Hood. Most of the batches have been dispensed and distributed. THIS IS A REPEAT OBSERVATION.

    2. Observation 4

      Exposure to sub-ISO5 air during transfer

      Sterile drugs and Materials were exposed to lower than ISO 5 quality air. Specifically, Your firm transfers (6) (4) vials filled with drug products intended to be sterile from ISO Class 5 Biological Safety Cabinets (BSCs) through the ISO Class 7 negative pressure cleanroom to (6) (4). During this transfer, the (6) (4) vials, which contain exposed sterile product, are subjected to air quality worse than ISO Class 5. Your firm also operates (15) (4) and (15) (4) located in the positive pressure cleanroom. (15) (4) vials are similarly transferred from ISO Class 5 hoods through the ISO Class 7 positive pressure cleanroom to these (15) (4), exposing sterile products to worse than ISO Class 5 air quality during this transfer. On 03/09/2026, I observed vials of HCG 12,000 IU Vial Lot # 15120575 Hood to (15) (4). The vials were carried in approximately (0)(4) trays, (6) (4) at a time, (b) (4) trays containing approximately (6) (4) vials and the (15) (4) tray was (15) (4) filled. Your firm's (6) (4) drug products compounded in negative and positive pressure clean rooms include but are not limited to: Tesamorelin, Human Chorionic Gonadotropin, NAD+, Trimix XL, Hexarelin, Sermorelin, FSH, Ipamorelin, Long R3-IGF, Gonadorelin, and SS-3. In the previous three months your firm produced (batches) of (15) (4) sterile drug products in the negative pressure room using (b) (4). In the positive pressure clean room in previous three months batches of sterile (b) (4) drug products were produced using (b) (4). Most of the batches have been dispensed and distributed. THIS IS A REPEAT OBSERVATION.

    3. Observation 5

      Unsterilized equipment/interiors

      Use of (6) (4) that are not sterilized by routine sterilization cycles and protected from contamination by sterilizing (6)(4) on vacuum break air lines/vents. Specifically, On 3/10/26, your Production Manager stated that all of the (6) (4) are cleaned after each production run using (15) (4) with a contact time of (6) (4), followed by (6) (4). (6) (4) sterilization is conducted (b) (4). Your firm does not use (o)(4) sterilization, (6) (4) sterilization, or any other validated sterilization method to sterilize the interior chambers of the (15) (4) between production runs or on a routine basis. THIS IS A REPEAT OBSERVATION.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 14 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Observation 1

      Exposure to sub‑ISO‑5 air

      Sterile drugs and Materials were exposed to lower than ISO 5 quality air. Specifically, A. Your firm's product, Trimix Gel (300 mcg / 100 mcg / 1000 mcg per ml), is prepared with nonsterile [(b) (4)] that is staged in an unclassified area. After the sterilization cycle, the open [(b) (4)] then capped using a 'sterile' cap before it is transferred into ISO 8/7 areas and ultimately, into an ISO 5 BSC for further processing. On [illegible] Gel (300 mcg/100 mcg/1000 mcg per ml) for [illegible] BUD:03/05/2025, with an uncapped [(b) (4)] in an unclassified area. There is no assurance that the unclassified area where the non-sterile [(b) (4)] is sterilized and use of a 'sterile cap' are not rendering the product or environment that is less than ISO 5 critical air. B. Your firm transfers [(b) (4)] vials filled (6) [(~)] located within an ISO 7 area, thereby exposing those sterile [illegible] to worse than ISO 5 qualified air. On 11/24/2024, your [illegible] product intended to be sterile from the ISO 5 BSC, hood [illegible] cleanroom area to use the Trehalose, Lot 9924515, BUD:05/06/2025.

    2. Observation 2

      Microbial contamination recoveries

      Microbial contamination was present in the ISO 5 area and areas adjacent to production areas. Specifically, A. Your firm fails to add additional routine environmental monitoring to the ISO 5 and ISO 7 critical areas to ensure that the processing conditions are free of mold, yeast, and other spore forming microorganisms found in your ISO 7 cleanroom areas and during routine personnel gowning qualifications. i. On 01/24/2024, a recovery of Too Numerous To Count (TNTC) CFU [illegible] positive, spore forming bacteria, Paenibacillus glucanolyticus, was recovered in the ISO 7 prep cleanroom used to prepare and mix solutions; ii. On 11/23/2023, a 3 CFU recovery of mold, Penicillium sumatrense, was recovered in the ISO 7 preparation [(b) (~)] hood used to prepare and mix solutions; iii. On 08/01/2023, there were three separate recoveries inside the ISO 7 negative pressure clean room used in the processing [illegible] identified as unknown species of Streptococcus, Penicillium citrinum, and 3 CFU of another mold species, Penicillium sumatrense; iv. On 09/03/2024, a passing gowning competency check sampled to have 1 CFU of Aspergillus and 2 CFUs of a gram-positive cocci recovered on their forehead. B. While your firm has defined an action limit of [illegible] CFU, it was changed in December 2024 to a specification of [illegible] CFU within the ISO 5 critical area. Your firm failed to address these excursions and released the following batches for distribution: i. On 12/4/2024, your firm had 1 CFU recovery [illegible] during the production of [illegible]; ii. On 10/2/2024, your firm had 1 CFU recovery [illegible] during the production of Testosterone cypionate, [illegible]; iii. On 06/24/2024, your firm had two recoveries in hood 3 during the production of HCG 12,000 unit vials Lot 9089665 identified as Staphylococcus hominis. C. On 08/01/2023, your firm had ten separate recoveries identified as either Penicillium citrinum, Cladosporium, Streptococcus [illegible] in the ISO 7 negative cleanroom, which was not addressed through an investigation, additional sampling, or robust cleaning. Furthermore, on 08/01/2023, [illegible] 41 CFUs and 1 CFU (Action Limit [illegible] CFUs) [illegible] 1 CFU identified as Micrococcus species [illegible] drug product. D. On 08/06/2024, your aseptic technician performed [illegible] performance while inside of BSC hood and Bacillus species was found. Both media fill and environmental monitoring performance are documented as successful without any evaluation for the microorganism recovery.

    Show 12 more observations
    1. Observation 3

      Inadequate environmental monitoring

      Lack of and Inadequate routine environmental monitoring in the ISO 5 area and classified areas. Specifically, your firm does not perform an environmental monitoring surface sample when performing aseptic processing directly within 6 inches of the work area that the process is being performed. On 01/27/2025, the firm's quality technician was observed to take a sample of the work bench approximately a foot away from the direct area where drug product [illegible] was being processed. Furthermore, when placing the media plate inside the ISO 5 BSC a copious amount of sterile [illegible] was directly sprayed on the closed media plate which was then placed directly on the work surface which was directly sampled once opened and applied to the work bench area. Example drug product: Semaglutide 5 mg/ml 2 cc, Lot 10453555 BUD 4/27/2025.

    2. Observation 4

      Inadequate media fill program

      Failure to conduct media fills that closely simulate aseptic production operations under worst-case, most-challenging, and stressful conditions. Specifically, your firm's media fill program is deficient in that your media fills are not representative of the batch size, container type, and equipment used for sterile operations. A. Your firm does not have a media fill for [illegible] prepares syringe [illegible]; syringe for Trimix Gel [illegible] insertion without having conducted the appropriate media fill to demonstrate and assess aseptic processing when filling a [illegible]. B. Your firm does not include interventions such as [illegible] in the media fill program. The following products are not represented: Bimix (150 mg / 5 mg) per Vial for Injection; FSH 1500 IU Vial for Injection; Hexarelin 6 mg per Vial for Injection; Human Chorionic Gonadotropin (hCG) 6,000 IU Vial For Injection; Human Chorionic Gonadotropin (hCG) 12,000 IU Vial For Injection; Human Chorionic Gonadotropin (hCG) 50,000 IU Vial For Injection; NAD+ 1000 mg per Vial for Injection; Quadmix (150 mg / 10 mg / 100 mcg / 1000 mcg) per Vial; Sermorelin 15 mg per Vial for Injection; SS-31 300 mg per Vial For Injection; Tesamorelin 12 mg per Vial for Injection; Trimix (150 mg / 5 mg / 50 mcg) per Vial for Injection; Trimix XL (150 mg / 10 mg / 100 mcg) per Vial; Trimix 60 (150 mg / 30 mg / 300 mcg) per Vial for Injection; Gonadorelin 2 mg per vial for Injection.

    3. Observation 5

      Static smoke studies only

      Smoke studies were not performed under dynamic conditions. Specifically, your smoke studies conducted August 22, 2024, during the cleanroom recertification are inadequate. For example, your firm's smoke studies do not consist of dynamic testing to assess complex interventions within the ISO 5 biosafety cabinet. This is a repeat OBSERVATION.

    4. Observation 6

      Inadequate cleaning/disinfection

      Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area. Specifically, your firm has not established a process for cleaning HEPA filters within the biosafety cabinet to ensure they are maintained and purported to be sterile. Your firm produces approximately [illegible] products in the [(b) (4)] ISO 5 BSC hood and [illegible] work surface area of the BSC, missing the [illegible] product made in the same [(b) (4)] BSC. Your firm has not demonstrated prevention of potential cross contamination. Two drugings [sic] were observed: Semaglutide 5 mg/ml 2 cc, Lot 10453555 BUD 4/27/2025, and Sermorelin 15 mg, Lot 10453561 BUD 7/26/2025.

    5. Observation 7

      Unsterilized lyophilizers

      Use of lyophilizers that are not sterilized by routine sterilization cycles and protected from contamination by sterilizing filters on vacuum break air lines/vents. Specifically, your firm does not use the sterilization cycle on the [illegible] lyophilizer units located in your cleanroom areas to protect them from contamination. Furthermore, your firm is not using meaningful environmental monitoring data to include [illegible] samples inside the [(b) (4)] units.

    6. FDCA 501(a)(2)(A)

      Media fills, failure

      Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

    7. FDCA 501(a)(2)(A)

      Inadequate smoke studies

      Smoke studies were not performed under dynamic conditions.

    8. FDCA 501(a)(2)(A)

      Exposed to lower quality air/ISO 5

      Sterile drugs and Materials were exposed to lower than ISO 5 quality air.

    9. FDCA 501(a)(2)(A)

      Lyophilizers, inadequately or not sterilized

      Use of lyophilizers that are not sterilized by routine sterilization cycles and protected from contamination by sterilizing filters on vacuum break air lines/vents.

    10. FDCA 501(a)(2)(A)

      Microbial contamination was present, ISO 5/areas adjacent

      Microbial contamination was present in the ISO 5 area and areas adjacent to production areas.

    11. FDCA 501(a)(2)(A)

      Failure to clean and disinfect/sterilize equipment, ISO 5 area

      Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.

    12. FDCA 501(a)(2)(A)

      Lack of/inadequate, environmental monitoring

      Lack of and Inadequate routine environmental monitoring in the ISO 5 area and classified areas.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Poor aseptic technique blocking first air

      Personnel were observed conducting aseptic manipulations or placing equipment/supplies in an area that blocked the movement of first pass air around an open unit, whether before or after it is filled with sterile product Specifically, A. On 4/26/2022 aseptic processing visual observations were made of the sterile drug product, (b)(4) Sterile Solution for Injection, Lot # (b)(4) BUD 10/23/2023, your firm pharmacy technician while placing rubber stoppers in finished product filled vials, was observed reaching over open vials. Following our discussion regarding poor aseptic techniques, your firm decided to dispose of this observed sterile lot. B. On 4/19/2022, while visually observing the aseptic processing of the sterile drug product, (b)(4), Lot # (b)(4), BUD 7/31/22, I observed your firm pharmacy technician use poor aseptic techniques in the positioning of the syringe to form the connection with the tubing which inhibited the presence of 1st air when forming the connections between each syringe fill. Following our discussion regarding poor aseptic techniques, your firm decided to dispose of this observed sterile lot. C. On 4/19/2022, while visually observing the aseptic processing of the sterile drug product, (b)(4), Lot # (b)(4), BUD 7/31/22, I observed both your PIC and pharmacy technician failed to disinfect sterile gloves prior to returning and place processing components inside ISO 5 BSC, while placing drug components into and removing trash from the BSC during processing of the sterile drug product. Following our discussion regarding poor aseptic techniques, your firm decided to dispose of this observed sterile lot.

    2. Observation 2

      Non-pharmaceutical grade sterilizing filter used

      The (b)(4) intended to render final product sterile is not adequate to accomplish (b)(4) and/or is not pharmaceutical grade. Specifically, your firm fail to use sterile pharmaceutical grade (b)(4) during the processing of sterile drug products. For example, your firm uses a (b)(4), during the aseptic processing of the finished sterile drug product, Dexamethasone 24 mg/ml Sterile Solution pH 7. A review of your firm Production Log, I found 2 Lots produced that remain within expiry, Lot # 585669 (BUD 6/18/2022) and 668512 (BUD 8/15/2022). There have been 6 (six) patient-prescriptions dispensed from the aseptically process lots.

    Show observations 3 to 9
    1. Observation 3

      Inadequate HEPA coverage over sterile exposure areas

      There is inadequate HEPA filter coverage or airflow over the area to which sterile product is exposed. Specifically, your firm has (b)(4) Systems in the cleanroom. (b)(4) does not appear to have enough HEPA filters in proper locations to provide adequate coverage to ensure ISO 5 environment is maintained from the ISO 5 BSC used for aseptic processing, to the (b)(4) and from the (b)(4) to the (b)(4) crimping station. This is a repeat observation.

    2. Observation 4

      Filter integrity testing not adequately performed

      (b)(4) integrity testing to the (b)(4) was not performed. Specifically, your firm failed to adequately test and record the results from (b)(4) testing of the Sterile (b)(4) On 4/19/2022 and 4/26/2022, I observed your firm perform a (b)(4) test on the (b)(4) used to render the process drugs, (b)(4), Lot # (b)(4), BUD 7/31/22 and (b)(4) Sterile Solution for Injection (Continuation Dose), Lot # (b)(4) 10/23/2023, respectively, by your firm pharmacy technician. She was unable to adequately provide sufficient pressure using a (b)(4) syringe to deliver the (b)(4) which would test the (b)(4) to the manufacturer's specification. Your firm following our discussion of observed deficiencies disposed of both aseptically processed lots.

    3. Observation 5

      Sinks drains present near ISO 5 area

      Sinks or drains are present in the cleanroom where the ISO 5 area is located. Specifically, your firm's (b)(4) system, located approximately (b)(4) feet apart within the ISO 7 Buffer Room/Cleanroom, require water to drained from the unit using a (b)(4) plastic bucket that was in your firm's ISO 8 Ante Room/Gowning at the completion of a cycle. Your firm's (b)(4) are located adjacent to ISO 5 BSC and the ISO 5 LAFU used for aseptic processing and (b)(4) crimping equipment respectively.

    4. Observation 6

      Unsealed ceiling tiles and sprinkler in cleanrooms

      Unsealed, loose ceiling tiles were observed in your cleanroom. Specifically, I observed an exposed/unsealed fire sprinkler head within your firm's ISO 8 Ante Room/Gowning, and ISO 7 HD Anteroom/Prep Room, and ISO 7 Buffer Room/Cleanroom along with unsealed ceiling tiles.

    5. Observation 7

      Dirty difficult-to-clean ISO classified surfaces

      The ISO-classified have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. Specifically, foreign particulates were observed on the top of the firm's ISO 5 BSC, ISO 5 LAFU and (b)(4) systems located in the ISO 7 Non-Hazardous Buffer Room.

    6. Observation 8

      Inadequate dynamic smoke studies

      Cleanroom smoke studies conducted in cleanroom under dynamic conditions are inadequate. Specifically, your firm's smoke studies conducted as part of your firm August 18, 2021, Cleanroom re-certification is inadequate. For example, your firm's smoke studies failed to include and assess complex intervention(s) within your firm's ISO 5 BSC as part of the unit's recertification process.

    7. Observation 9

      Sterile glassware exposed to less than ISO 5

      (b)(4) glassware used in the processing of sterile drug product is exposed to less than ISO 5 air quality. Specifically, your firm failed to ensure (b)(4) glassware used in aseptic processing is not exposed to less than ISO 5 air. For example, on 4/19/2022, your firm was observed using an uncovered glass beaker that had undergone (b)(4), used in the processing of the sterile drug product, (b)(4) vial for injection, Lot #(b)(4), BUD 7/31/22 within your firm's ISO 7 HD Ante Room and ISO 7 Non-Hazardous Buffer Room. The breaker contains the bulk (b)(4) drug product, (b)(4) during mixing of drug components and transfer prior to (b)(4) within the ISO 7 Non-Hazardous Buffer Room.

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate ISO 5 certification

      The certification of the ISO 5 areas was inadequate. Specifically, smoke studies were not conducted to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions.

    2. Observation 2

      Inadequate depyrogenation validation

      The [(b) (4)] used for depyrogenation of product/equipment intended to be sterile were not lethal to heat-resistant microorganisms. Specifically, Your firm uses a [(b) (4)] to depyrogenate glassware used in the preparation of your firm's sterile injectable products. However, you do not use endotoxin indicators to ensure and verify that the [(b) (4)] and [(b) (4)] used to depyrogenate glassware is adequate.

    Show observations 3 to 5
    1. Observation 3

      Media fills not representative

      Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your Media Fill Challenge log sheet documents that a total of [illegible] trials ([illegible] for control and [illegible] for evaluation) will be used to conduct media fills. Review of media fills conducted since 8/2020 revealed that the media fills were not representative in that your firm failed to simulate actual production processes. In addition, your firm does not include an evaluation of the transfer of vials to and from the ISO 5 hood to the [(b) (4)]. For example, your firm produces several [(b) (4)] products at your facility including Ipamorelin and HCG. For example, a typical lot of Human Chorionic Gonadotropin 12,000 TU Vial for Injection is [illegible] vials.

    2. Observation 4

      Sterile product exposed to non-ISO5 air

      Product intended to be sterile was exposed to lower than ISO 5 classified quality air. Specifically, your firm's procedure for [(b) (4)] finished drug products includes [(b) (4)] vials under the ISO 5 laminar flow hood and then removing these vials outside the hood to transfer into the [(b) (4)].

    3. Observation 5

      Use of non-pharmaceutical grade components

      Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. For example, your firm uses [(b) (4)] produced via [illegible] process in-house which is used as a component in various non-sterile products. Your firm has no documentation to substantiate that the [(b) (4)] produced by [illegible] meets, minimally, the specifications for [(b) (4)] USP. Some examples of drug products which use the [(b) (4)] include the following: PTD-DBM 0.03%/Sodium Valproate 5% 30 ml spray and Clindamycin 1.2%/Benzoyl Peroxide 5% Gel.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.

  • Inspection ending Feb 7, 2025OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Oct 8, 2026FDA-FOIA-2026-9822Form 483· 1 of 5 sitesRecords released
    2. Aug 25, 2025FDA-FOIA-2025-10165EIRWithdrawn
  • Inspection ending May 4, 2022VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. FY2023FDA-FOIA-2023-3084Inspection recordsNo records found
  • Inspection date not given

    2 requests. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-3618Inspection recordsClosed
    2. Jun 15, 2022FDA-FOIA-2022-4392Inspection recordsWithdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3016710945 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3016710945. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.