The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate ISO 5 certification

    The certification of the ISO 5 areas was inadequate. Specifically, smoke studies were not conducted to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions.

  2. 2

    Inadequate depyrogenation validation

    The [(b) (4)] used for depyrogenation of product/equipment intended to be sterile were not lethal to heat-resistant microorganisms. Specifically, Your firm uses a [(b) (4)] to depyrogenate glassware used in the preparation of your firm's sterile injectable products. However, you do not use endotoxin indicators to ensure and verify that the [(b) (4)] and [(b) (4)] used to depyrogenate glassware is adequate.

  3. 3

    Media fills not representative

    Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your Media Fill Challenge log sheet documents that a total of [illegible] trials ([illegible] for control and [illegible] for evaluation) will be used to conduct media fills. Review of media fills conducted since 8/2020 revealed that the media fills were not representative in that your firm failed to simulate actual production processes. In addition, your firm does not include an evaluation of the transfer of vials to and from the ISO 5 hood to the [(b) (4)]. For example, your firm produces several [(b) (4)] products at your facility including Ipamorelin and HCG. For example, a typical lot of Human Chorionic Gonadotropin 12,000 TU Vial for Injection is [illegible] vials.

  4. 4

    Sterile product exposed to non-ISO5 air

    Product intended to be sterile was exposed to lower than ISO 5 classified quality air. Specifically, your firm's procedure for [(b) (4)] finished drug products includes [(b) (4)] vials under the ISO 5 laminar flow hood and then removing these vials outside the hood to transfer into the [(b) (4)].

  5. 5

    Use of non-pharmaceutical grade components

    Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. For example, your firm uses [(b) (4)] produced via [illegible] process in-house which is used as a component in various non-sterile products. Your firm has no documentation to substantiate that the [(b) (4)] produced by [illegible] meets, minimally, the specifications for [(b) (4)] USP. Some examples of drug products which use the [(b) (4)] include the following: PTD-DBM 0.03%/Sodium Valproate 5% 30 ml spray and Clindamycin 1.2%/Benzoyl Peroxide 5% Gel.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3016710945, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.