Revive Rx, LLC dba Revive Rx Pharmacy Form 483, August 2021
FDA issued this Form 483 to Revive Rx, LLC dba Revive Rx Pharmacy in Houston, Texas (FEI 3016710945) at the end of a drug inspection that ended August 6, 2021. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 28, 2021. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Aug 6, 2021
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Oct 28, 2021
- 83 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate ISO 5 certification
The certification of the ISO 5 areas was inadequate. Specifically, smoke studies were not conducted to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions.
- 2
Inadequate depyrogenation validation
The [(b) (4)] used for depyrogenation of product/equipment intended to be sterile were not lethal to heat-resistant microorganisms. Specifically, Your firm uses a [(b) (4)] to depyrogenate glassware used in the preparation of your firm's sterile injectable products. However, you do not use endotoxin indicators to ensure and verify that the [(b) (4)] and [(b) (4)] used to depyrogenate glassware is adequate.
- 3
Media fills not representative
Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your Media Fill Challenge log sheet documents that a total of [illegible] trials ([illegible] for control and [illegible] for evaluation) will be used to conduct media fills. Review of media fills conducted since 8/2020 revealed that the media fills were not representative in that your firm failed to simulate actual production processes. In addition, your firm does not include an evaluation of the transfer of vials to and from the ISO 5 hood to the [(b) (4)]. For example, your firm produces several [(b) (4)] products at your facility including Ipamorelin and HCG. For example, a typical lot of Human Chorionic Gonadotropin 12,000 TU Vial for Injection is [illegible] vials.
- 4
Sterile product exposed to non-ISO5 air
Product intended to be sterile was exposed to lower than ISO 5 classified quality air. Specifically, your firm's procedure for [(b) (4)] finished drug products includes [(b) (4)] vials under the ISO 5 laminar flow hood and then removing these vials outside the hood to transfer into the [(b) (4)].
- 5
Use of non-pharmaceutical grade components
Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. For example, your firm uses [(b) (4)] produced via [illegible] process in-house which is used as a component in various non-sterile products. Your firm has no documentation to substantiate that the [(b) (4)] produced by [illegible] meets, minimally, the specifications for [(b) (4)] USP. Some examples of drug products which use the [(b) (4)] include the following: PTD-DBM 0.03%/Sodium Valproate 5% 30 ml spray and Clindamycin 1.2%/Benzoyl Peroxide 5% Gel.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3016710945, newest first.
- Form 483, March 2026FDA record date Mar 27, 2026 · Posted Apr 22, 2026
- Form 483, February 2025Inspection ended Feb 7, 2025 · Posted Mar 28, 2025OAI
- Form 483, May 2022Inspection ended May 4, 2022 · Posted Sep 27, 2022VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.